DW1500274Rev.K3Mar 6, 2017Installation InstructionsBefore InstallationPlease read these instructions carefully and keep for futurereference.The information in this document is subject to change withoutnotice. For updates please refer to our website.CAUTION!・Do not use the products outside the rated power supply voltagerange specified in the Specifications. It may cause a fire ordamage to equipment.・Do not disassemble, repair, or modify the products. It may causea fire or electric shock.・Make sure to turn the power off before commencing any wiringwork. Otherwise it may cause electric shock or damage toequipment.・Do not use any tester other than the one specified for testing. Itmay cause damage to equipment.Note・Follow the requirements for the installation of the products inaccordance with the Specifications. Otherwise it may causemalfunction.・The products should not be installed in the following places, as itmay cause damage to equipment:- Place with plenty of air flow (close to a ventilation fan, airconditioner, or place with drafts)- Place close to heating appliance- Place with a constantly high temperature or humidity- Place with lots of dust or insects- Place with exhaust gas such as garage- Place where oil, dust, iron powder, chemicals, or hydrogensulphide may occur or affect the productsThese instructions explain how to install and test UL Listed Nittandetectors and bases.For the details of each product, please refer to “Instruction Manual”on the website: http://www.nittan.comTable 1: UL Listed Product Instruction ManualCAUTION!Install the detectors/bases in accordance with these instructions,applicable NFPA standards, local codes, and the authoritieshaving jurisdiction. Failure to follow these instructions may resultin failure of detectors to initiate an alarm condition. Nittan is notresponsible for detectors and bases that have been improperlyinstalled, tested, or maintained.Table 2: Electrical box for baseBASE Model Applicable electrical box3-1/2” Oct 4” Oct 4” SquareEVA-UB4 ✓ - -EVA-UB4-6 ✓ ✓ ✓EVA-S6 Base ✓ ✓ ✓EVA-STB-RL ✓ - -EVA-STB-RLwithSTBA-ADP- ✓ ✓EVA-STB-SCI ✓ - -EVA-STB-SCIwithSTBA-ADP- ✓ ✓Connect wiring to the detectors/bases as shown in the Section2.Detectors and bases may be mixed on the same initiating loop aslong as the number of two-wire powered detectors does notexceed the specifications of the control panel. For thespecifications of detectors/bases, see Table 3.Product category Model number Manual partnumber VersionControl Panel NFU-7000 series LT-894NIT Rev 2.1DetectorEVA-PY DW1401832 Rev.K1EVA-PYH DW1401831 Rev.K1EVA-H2 DW1401833 Rev.K1EVA-H2-HEVA-DPH DW1401834 Rev.K1EVCA-P(-Z) DW1500110 Rev.K2BaseEVA-UB4 DW1401959 Rev.K1EVA-UB4-6EVA-STB-RL DW1401853 Rev.K1EVA-STB-SCI DW1401852 Rev.K1EVA-S6 Base DW1401960 Rev.K1ModuleEVA-DIP-SCI DW1401989 Rev.K1EVA-DOP-SCI DW1401991 Rev.K1EVA-DOP-AC240V-SCI DW1401992 Rev.K1EVA-SCI DW1401994 Rev.K1EVA-SCM-SCI DW1401995 Rev.K1EVA-MiniIP DW1401993 Rev.K1EVA-ZMU-SCI DW1401990 Rev.K1End of line PCE DW1401961 Rev.K1Adapter MountingPlate STBA-ADP DW1402124 Rev.K1NITTAN COMPANY, LIMITED1-54-5 SASAZUKA, SHIBUYA-KU, TOKYO 151-8535, JAPANhttp://www.nittan.com