Nora Lighting NX-504-LED Installation Instructions Manual
READ PRIOR TO ATTEMPTING INSTALLATIONALWAYS TURN OFF MAIN POWER BEFORE INSTALLATIONINSTALLATION SHOULD BE CARRIED OUT BY YOUR LOCAL ELECTRICIAN6505 Gayhart Street, Commerce, CA 90040Tel 800.686.6672 | www.noralighting.com | e-mail: nora@noralighting.com© 2019 Nora Lighting, Inc. All rights reserved. Instructions subject to change without notice.Installation InstructionsNX-504-LEDLED Exit Sign with Emergency Circuit111319P1IS-NX-504R01IMPORTANT SAFEGUARDS:READ AND FOLLOW ALL SAFETY INSTRUCTIONS1. Review the diagrams thoroughly before beginning. If you feel you do not have electrical wiring experience, refer to do-it-yourself wiring handbook or have your fixture installed by a qualifiedlicensed electrician.2. All electrical connections must be in accordance with local codes, ordinances, and the National Electric Code. If you are unfamiliar with these methods of installing electrical wiring, refer tothe services of a qualified licensed electrician.3. Before starting the installation, disconnect the power by turning off the circuit breaker or by removing the appropriate fuse at the fuse box. Turning the power off using the light switch is notsufficient to prevent electrical shock.4. Do not use outdoors.5. Do not let the power supply cords touch hot surfaces.6. Do not mount near gas or electric heaters.7. Use caution when servicing batteries. Battery acid can cause burns to skin and eyes. If acid is spilled on skin or in eyes, flush acid with fresh water and contact a physician immediately.8. Equipment should be mounted in a location and at a height where it will not readily be subject to tampering by unauthorized personnel.9. The use of accessory equipment that is not recommended by the manufacturer may cause an unsafe condition.10. Do not use this equipment for other than intended use.11. All servicing should be performed by qualified personnel only.12. Allow battery to charge for 24 hours before first use.SIDE MOUNTING1. Plastic housing2. EXIT panel3. Back plate4. Mounting hole cover5. Snap-in directional arrow6. Red or green diffuser7. Canopy8. Canopy screws9. Wire nuts10. Junction box (building utility)11. Crossbar12. Crossbar screws (not provided)13. Holding wireSIDE MOUNTING:1. 1. Attach crossbar (11) to junction box (10).2. 2. Feed lamp leads through side hole, making sure to secure wire into wire guides found at the edges of the sign.3. 3. Attach sign to canopy (7) by inserting canopy into sign at an angle, then twist to secure.4. 4. Make the proper lamp lead connections. If using 120VAC, connect the black and white leads to the building utility. If using 277VAC, connect orange and white leads to the building utility. In allcases use standard wire nuts in connection of the leads. (See Wiring Diagram ).(In attaching wires you may use the enclosed “holding wire” (13) for assistance. See Diagram).5. 5. Push excess wire into junction box and secure back plate (3) to junction box (10). Then align holes in canopy with those in crossbar (11). Using screws and washers supplied, tighten canopy tocrossbar so that canopy is securely fastened and tight against wall.6. 6. Snap in arrows (5) to EXIT panel (2) as required, storing unused arrows in a safe place. Snap supplied covers(4) into ceiling mounting hole. The snap EXIT panel (2) to housing top first and thenbottom.CEILING MOUNTINGCEILING MOUNTING:1. 1. Attach crossbar (11) to junction box (10).2. 2. Feed lamp leads through top hole, making sure to secure wire into wire guides found at the edges of the sign.3. 3. Attach sign to canopy (7) by inserting canopy into sign at an angle, then twist to secure.4. 4. Make the proper lamp lead connections. If using 120VAC, connect the black and white leads to the building utility. Ifusing 277VAC, connect orange and white leads to the building utility. In all cases use standard wire nuts in connectionof the leads. (See Wiring Diagram). (In attaching wires you may use the enclosed “holding wire” (13) for assistance. SeeDiagram.)5. 5. Push excess wire into junction box and then align holes in canopy with those in crossbar. Using screws and washerssupplied, tighten canopy to crossbar so that canopy is securely fastened and tight against ceiling.6. 6. Snap in arrows (5) to EXIT panel (2) as required, storing unused arrows in a safe place. Snap covers (4) to sidemounting hole. Then snap EXIT panel (2) to housing top first and then bottom.IMPORTANT - This equipment is intended to be installed only by qualified personnel. The installation must be made in accordance with the current edition of the National Electrical Code and all applicable state and localbuilding codes. The final installation must be approved by the appropriate, qualified electrical/building inspector(s). Improper installation may result in a fire or electrical hazard. Be sure the electrical power to the circuithas been disconnected before installing this electrical system.IMPORTANT - Cet équipement est destiné à être installé uniquement par du personnel qualifié. L’installation doit être faite conformément à l’édition actuelle du Code national de l’électricité et à tous les codes deconstruction locaux et nationaux applicables. L’installation finale doit être approuvée par un ou plusieurs inspecteurs qualifiés en électricité / bâtiment. Une installation incorrecte peut entraîner un incendie ou un risqueélectrique. Assurez-vous que l’alimentation électrique du circuit a été déconnectée avant d’installer ce système électrique. |
Related manuals for Nora Lighting NX-504-LED
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine