Rhino SD Single Amber Lens 24 VDCLight Tower for Electric Changeover ControlsInstruction Sheet: 1047114A 2004 Nordson Corporation Issued 2/04DescriptionSee Figure 1. The light tower (1) mounts to Rhino SDelectric changeover controls (2). The light tower has asingle amber lens that illuminates when a fault occursduring system operation.24 in.(61 cm)Figure 1 Typical Light TowerRepairUse the following procedures to replace a light tower.WARNING Allow only qualified personnel to perform thefollowing tasks. Follow the safetyinstructions in this document and all otherrelated documentation. Disconnect and lock out power to the systembefore performing repairs.Remove the Light Tower1. See Figure 2. Note the orientation of the hoseassembly (2, 3, 4A) and the upper clamp assemblyto the light tower (1).2. Loosen the screws (3) to remove the weld plate (5)and clamp body half (4B).3. Disconnect the cable (6) from the light tower (1).4. Remove the screws (3), washers (8), cover plate (9),clamp body halves (4A, 4B), and weld plate (5) thatsecure the light tower (1) to the control plate (7).Install the New Light Tower1. Install the new light tower in reverse order of theremoval procedure.2. See Figure 1. Make sure that the distance betweenthe upper clamp body and the control plateis 24 in. (61 cm).3. See Figure 2. Make sure that the upper clampassembly and hose assembly (2) are properlyorientated to the light tower (1).6574A4B912534A4BUPPER CLAMPASSEMBLYTYPICAL LOWERCLAMP ASSEMBLY4A4B3 83 8Figure 2 Replacing a Light Tower