Nortel 50 Series Quick Install Manual
Also see for 50 Series: Configuration guide
Contents |
Steps 1 3Before youstartSteps 4 10Mounting OptionsSteps 11 13Powering upSteps 14 21Initial Access andConfiguration! Perform steps 11 and12 in the order listed.BES50Business Ethernet Switch 50 SeriesQuick Install GuideYou can download all documentsreferenced in this Quick Install guide atwww.nortel.com.121110891345627 1314151617181920212. Confirm that you have the tools andpackage contents as follows:Tools Required:a. Phillips or flathead screwdriver, dependingon the type of screws used.Package contents:b. BES50FE-12/24T PWR orBES50GE-12/24T PWR switchc. Adhesive foot pads (4)d. AC power adapter3. Check your cables; when you installthe switch into a network make sure youuse the following required cables:• Category 3 UTP or STP cables with an RJ-45 connector(for 10BASE-T ports).• Category 5 UTP or STP cables with an RJ-45 connector(for 100BASE-TX ports).• Category 5, 5e, or 6 UTP or STP cables with an RJ-45connector (for 1000BASE-T ports).4. If you mount a BES50 unit on a desktop or shelf,attach the supplied rubber feet to the bottom of theunit. If the BES50 system includes additional units,you can set the additional units beside, or stackthem on top of, the first unit.The BES50FE12/24T and BES50GE12/24T switch units can bemounted horizontally on a flat surface and stacked with a BCM50.1. Download the Business ElementManager 1.0 Installer to acomputer on your network. Youinstall the Element Manager inStep 16.5. If you are mounting the additional unitsbeside the first unit, attach the suppliedrubber feet to the bottom of each unit.6. If you are stacking the additional units on top ofthe first unit, mount each unit into the tabs on topof another unit.8. To install a BCM50 unit on top of a BES50 unit, placethe BCM50 unit on top of the BES50.a. Set the device on a flat surface near an AC power source, makingsure there are at least two inches of space on all sides for proper air flow.b. If you install multiple switches, attach four adhesive feet to each one.Place each device squarely on top of the one below, in any order.9. Make sure the feet of the BES50 are in the slotson the top of the BCM50 unit and in front of the slots10. Slide the unit back until it clicks in place onthe slots.12. Plug the other endof the power adapterinto a grounded, 3-pinsocket, AC powersource.11. Insert the power adapterinto the DC power socket in thefront of the switch.14. To access the BES50, first install the Business ElementManager 1.0. Refer to Element Manager documentation atwww.nortel.com for instructions.15. Start the Element Manager.16. From the Element Managermenu, choose Network > FindNetwork Elements > BusinessEthernet Switch.17. Enter the range192.168.1.1 to192.168.1.255 and thenclick OK.Note: By default theRead Community is“PlsChgMe!RO” and theWrite Community is“PlsChgMe!RW”.18. Select the BES device from the list ofnetwork elements on the Element Managertree.19. Click the Web Page button on theElement Manager menu.20. Enter the default username(nnadmin) and password(PlsChgMe!) to log on to theBES50.21. From the main menu, choose Administration > Quick Start. TheQuick Start screen appears showing the IP address and other items thatyou can optionally configure. If you want to manually assign IP addresses,refer to Using the Nortel Business Ethernet Switch 50 at www.nortel.com.13. Check the front-panel LEDs as the devicepowers on to confirm that the PWR LED is green.If not, check that the power cable is correctlyplugged in.Refer to Using the Nortel Business Ethernet Switch 50at www.nortel.com for detailed installationinstructions.When you connect a PC directly to theBES50, use the default IP address 192.168.1.128You are now ready to use the BES50 series switch inyour network installation.N0128198BES50-FE/GE-24T PWR switchBES50-FE/GE-12T PWR switchRJ-45 Ports with PoEThe BES50 series switch performs a short self-testas soon as you connect the switch to the powersupply. The status LED will flash green during theself-test, then solid green when finished. If theStatus LED turns off, the device is not workingcorrectly. When the self-test finishes, the BES50starts switching data.7. If you mount the switch on adesktop or flat surface, attach thefour adhesive feet to the device asindicated.RJ-45 Ports with PoESystem Indicators Port/PoE Status IndicatorsSystem Indicators Port/PoE Status IndicatorsRJ-45 PortsSlots FeetCMYCMMYCYCMYKBES50_QuickInstallGuide4.pdf 9/13/2006 3:12:23 PM |
Related manuals for Nortel 50 Series
Nortel 2526T Quick Install Manual
Nortel 5500 Series Installation Manual
Nortel 4500 Series Installation Manual
Nortel 2350 Quick Start Manual
Nortel BayStack 350 Series Manual
Nortel 70 Series Installation And Reference Manual
Nortel 5510 Installation Manual
Nortel 325 series Cli Manual
Nortel 10 Installation Manual
Nortel 8000 Series Installing
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine