Notifier NBG-12LX Quick Start Manual
Also see for NBG-12LX: Operation manual
NORMALACTIVATED4 3 2 10 01011121314 15 1 12 23 34 4TENS ONES6 67 78 89 95 5UL Approved Label Here12345678901231234567890123123456789012312345678901231234567890123ADDRESSLOOP0 1234567890 1234567891011121314 15LED OPERATIONAlarm:Steady REDNormal CLIP Systems:Flash REDNormal FlashScan TM :Flash GREENNote: LED is visiblethrough translucenthandle.Setting the NBG-12LX AddressThe NBG-12LX Addressable pull station is factory preset withaddress 00. Set the address for the pull station by turning therotary address switches on the addressable module mounted insidethe pull station. Only one device per address is allowed. Multiplemodules may not be set to the same address on the Signaling LineCircuit. Once the address is set, record it in the space provided onthe product ID label located inside the pull station.NBG-12LX Addressable Pull StationDescriptionThe NBG-12LX Addressable pull station is a non-coded, dual-action manual pull station with a key-lock reset feature. Itprovides NOTIFIER intelligent control panels with one addres-sable alarm initiating input. The addressable module is housedinside the pull station. The NBG-12LX is compatible with allNotifier intelligent panels and will automatically operate in eitherFlashScan or CLIP (Classic Loop Interface Protocol) mode.FlashScan is a patented (U.S. Pat. No. 5,539,389) High SpeedCommunications Protocol. Refer to the FACP InstallationManual to determine if FlashScan protocol is supported.FlashScan or CLIP operating mode must be selected in theFACP. (This selection is not available or required in FACPs thatdo not support FlashScan, therefore CLIP mode is enabledby default.) No selection is required in the Pull Station. TheNBG-12LX meets the ADA requirement for a 5-lb. maximumpull force to activate the pull station. Operating instructions aremolded into the pull station handle along with Braille text.Molded Terminal numbers are also present.RatingsNormal Operating Voltage: 24 VDC.Average Operating Current (LED Flash): 300 μA.Temperature Range: 32o F - 120o F (0o C - 49o C).Relative Humidity Range: 10% - 93% non-condensing.Document 51093 Revision A2 ECN: 01-293 09/14/01InstallationThe NBG-12LX Addressable pull station can be surface mountedto a NOTIFIER SB-10 surface backbox or semi-flush mountedon a standard single-gang, double-gang or 4 (10.16 cm) squareelectrical box. The optional BG-TR trim ring can be used if theNBG-12LX is to be semi-flush mounted.Software Note for AM2020/AFP1010 ProgrammingThe NBG-12LX is an Alarm Initiating Module of software typempul. If you have an older system that does not support the mpulsoftware type, the software type mon may be used.If, during mounting of the pull station, the door becomes de-tached, complete the following steps to reattach the door to thebackplate. The door cannot be connected to the pull station if theunit is mounted to the backbox.1) Position the door and backplate side by side in the full openposition. (i.e. 180-degrees with respect to each other.)2) With the backplate position fixed, move the door behind thebackplate, as shown in the illustration, part A.3) Align the hinge posts and holes by bringing the door up tomeet the backplate, paying particular attention to the keyingthat occurs when the doors post hole is aligned to thebackplates hinge post. Refer to the illustration, part B.4) With the two pieces aligned and keyed together, slide the holesdown onto the posts. Refer to the illustration, part C.5) Holding the backplate, close the door slightly to lock the doorand backplate together.To use the NBG-12LXwith panels capable ofsupporting up to 159addresses, pry off thebreak-away addressblock using a flat-bladed screwdriver.The break-away pieceis illustrated below.ROTARY ADDRESS SWITCHESLEDLO OPN O T I F I E RNBG - 12 SeriesNO N-C O DEDFIRE A LARM B OXLISTED23424REFER TO D OC UMEN TMade inU. S. A.M AD DRESSLUPRODUCT IDENTIFICATION LABELrot switch 9-13.cdr, label_1.cdr, rotary box.cdrNBG12-Face2.cdrwww.PDF-Zoo.comfirealarmresources.com |
Related manuals for Notifier NBG-12LX
Notifier NBG-12LO Quick Start Manual
Notifier NBG-12LA Quick Start Manual
Notifier NBG-12LOB Quick Start Manual
Notifier NAM-232 Quick Start Manual
Notifier NBG-12LX Operation Manual
Notifier NBG-12S Installation Manual
Notifier AM2020 Manual
Notifier UZC-256 Manual
Notifier LCD-80F Manual
Notifier ONYX Series Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine