OBERON Aruba 1044-ARAP5 Series Installation Manual
Installation Guide / Guía de instalaciónfor Oberon Model 1044-ARAP5XX Series Arubapara Modelo Oberon 1044-ARAP5XX Serie Aruba Mounting Solutions for WiFi Access Points"Oberon" and all other marks where denoted are trademarks of Oberon Inc. ©1999-2020 Oberon Incorporated. All rights reserved."Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. ©1999-2020 Oberon Incorporated. Todos los derechos reserve.EPN 3781, 3995, 4008, & 4063 - Rev. 4/28/2020Cloud/canopy/suspended ceiling mounting kit for most vendors’APs and antennas. A cutout is made in the ceiling panel, thepanel bridge is placed above the ceiling panel, and the trim isthen drawn into the panel bridge with a torsion spring, as in cer-tain recessed lighting fixtures, with only the front face exposedfor optimal wireless coverage.Kit de montaje para cielorraso suspendido/dosel/nube para lamayoría de las antenas y AP de los proveedores. Se realiza unrecorte en el panel del cielorraso, se coloca el puente del panelpor encima del panel del cielorraso, se lleva al puente del panelcon un muelle de torsión, como en ciertos accesorios de ilumina-ción empotrados, con solo la cara frontal expuesta para teneruna cobertura inalámbrica óptima.Instructions are for typical install conditions. Instructions may not becorrect for all installations due to building design, construction ma-terials or methods used and/or building or site conditions. Consult acontractor or architect for recommendations. For product questionscall (+1) 877-867-2312.Las instrucciones son para condiciones típicas de instalación. Lasinstrucciones pueden no ser correctas para todas las instalacionessegún el diseño del edificio, materiales de construcción o métodosutilizados, o condiciones del edificio o del lugar. Consulte a un con-tratista o arquitecto para obtener recomendaciones. Si tienepreguntas con respecto al producto, llame al (+1) 877-867-2312.Thank you for choosing Oberon. / Gracias por elegir Oberon.WARNING / ADVERTENCIAFollow manufacturer's instructions for hand or power tools.Always use safety glasses. Failure to do so may result in injuryand/or product damage.Siga las instrucciones del fabricante para herramientas manu-ales o eléctricas. Utilice siempre gafas de seguridad. Si no lohace, podría producirse lesiones y / o daños al producto.WARNING / ADVERTENCIAUse caution when working at elevated heights. Follow manu-facturer's instructions for ladders and/or scaffolding. Failure todo so may result in injury or death.Tenga cuidado al trabajar a alturas elevadas y alrededor de lasaberturas de la unidad. Siga las instrucciones del fabricantepara laddors y / o andamios. Si no lo hace, podría causar le-siones o la muerte.Important Information for Model 1044 / Información importante para el modelo 1044Read guide from beginning to end before beginning installation.Read all warnings and cautions before beginning unit installa-tion. Check with your local building code official to identify andconfirm compliance with local building code requirements. Thisinstallation guide covers installing your Model 1044 in a typicalenvironment. The appropriate method for your installation mayvary based on building design, application, and industry practic-es.Lea la guía de principio a fin antes de comenzar la instalación.Lea todas las advertencias y precauciones antes de comenzar lainstalación de la unidad. Verifique con un oficial de códigoedilicio de su localidad para identificar y confirmar el cumpli-miento con los requisitos locales del código de edificación. Estaguía de instalación cubre la instalación del Modelo 1044 en unentorno adecuado. El método apropiado para la instalaciónpuede variar según el diseño del edificio, la aplicación y lasprácticas de la industria.1. Ceiling mounted products should be installed in accordance with National Electric Code paragraphs 300.10 (Electrical Continuity of Metal Raceways andEnclosures) and 300.11 (Securing and Supporting). Independent support wires or other means must be used for the installation of this product in the ceiling.Acoustical, suspended, false, drop and concealed spline ceiling grid work is not designed to support the weight of this product. Oberon’s ceiling mountedproducts have four support wire tabs on the back box. These tabs shall be used for supporting the product with independent support wires, wire rope, thread-ed rod, or other secure support means of adequate gauge and fire resistance. A UL listed anchor or fastener suitable for the building material and type ofconstruction shall be used to anchor the support mechanism.2. The Cabinet System Communication is configured in the field by qualified service personnel.3. When closing the enclosure access door, be sure that the cam lock is completely engaged to prevent the access door from accidentally swinging open.4. When opening the enclosure door, be sure to support the door to prevent the door from accidentally falling open.5. This enclosure has a maximum operating ambient of 55º C (131º F). The temperature within the enclosure may not exceed this temperature, depending onpower dissipation within enclosure.6. A minimum air clearance of 1“ between the housing of the access point and the enclosure side walls must be maintained for the safe operation of theequipment.7. This product is intended to be installed by trained personnel.8. Only Listed ITE products shall be installed within the enclosure.9. This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or replacement.10. Maximum weight to be installed in the unit is 25 lbs.11. All knockouts, openings, and holes shall be sealed with a plug constructed of metal, or a non-metal material that complies with UL 2043 or UL 1479.12. All unused mounting holes should be sealed with tape or other material that complies with UL 1479.13. AC Power is not to be used inside the enclosure.14. A readily accessible disconnect device shall be incorporated in the building installation wiring.15. See OSHPD approved installation drawing where applicable.1. Los productos a montar en el cielorraso deben instalarse de acuerdo con los párrafos 300.10 (Continuidad Eléctrica de Canalizaciones y Recintos de Met-al) y 300.11 (Aseguramiento y Soportes) del Código Eléctrico Nacional. Deben utilizarse cables independientes de soporte u otros medios para la instalaciónde este producto en el cielorraso. Las rejillas de cielorraso estriadas acústicas, suspendidas, falsas, en desnivel y ocultas no están diseñadas para soportarel peso de este producto. Los productos para montar en cielorraso de Oberon tienen cuatro pestañas para cable de soporte en la caja posterior. Estas pesta-ñas deben utilizarse para sujetar el producto con cables independientes, cables de acero, varillas roscadas u otro medio de soporte seguro, de caliber adec-uado y resistencia al fuego. Se debe usar un ancla o sujetador con certificación UL adecuado para el material de construcción y el tipo de construcción paraanclar el mecanismo de soporte.2. La comunicación del sistema del gabinete está configurada en el campo por personal de servicio calificado.3. Al cerrar la puerta de acceso al recinto, asegúrese de que el seguro de leva esté completamente trabado para evitar que la puerta de acceso se abra poraccidente.4. Al abrir la puerta de la cubierta, asegúrese de sostener la puerta para evitar que se abra por accidente.5. Esta cubierta tiene un entorno máximo de funcionamiento de 55 °C (131 °F). La temperatura dentro de la cubierta no puede exceeder este valor, de-pendiendo de la disipación de energía dentro de la misma.6. Debe mantenerse un espacio mínimo de 1" entre la carcasa del punto de acceso y las paredes laterales de la cubierta para el funcionamiento seguro delequipo.7. Este producto debe ser instalado por personal capacitado.8. Solo productos homologados por ITE pueden instalarse dentro de la cubierta.9. Este producto debe ser reparado por personal capacitado por el fabricante o devuelto al fabricante para su reparación o reemplazo.10. El peso máximo a instalar en la unidad es de 25 libras.11. Todos los perforados, las aberturas y los orificios deben sellarse con un tapón de metal o de un material no metálico que cumpla con las normas UL 2043o UL 1479.12. Todos los orificios de montaje sin usar deben sellarse con cinta u otro material que cumpla con la norma UL 1479.13. Dentro de la cubierta no debe utilizarse corriente alterna.14. Se deberá incorporar un dispositivo de desconexión fácilmente accesible en el cableado de la instalación del edificio.15. Consulte el plano de instalación aprobado por OSHPD donde corresponda.Important code and installation information. / Información im-portante sobre normas e instalación.(1) Backbox / Caja de conexiones(1) Trim / Recorte(1) Dual Cable Egress Firestop Grommet /Arandela cortafuegos doble salida de cable(1) 1” Trade Size Conduit Connector /Conector de conducto de tamaño comercial de 1"(4) #6-32 x 1 1/4" Screws / Tornillos #6-32 x 1 1/4"(4) Hanger Wires / Cables de suspensiónParts Included / Partes incluidas |
Related manuals for OBERON Aruba 1044-ARAP5 Series
OBERON Aruba 1042-ARAP5 Series Installation Manual
OBERON 1043-ARAP5 Series Installation Manual
OBERON Aruba Series Installation Manual
OBERON 1016-ANTPLATE Series Installation Manual
OBERON 1042-FL Installation Manual
OBERON Skybar 3001-00 Series Installation Manual
OBERON NetPoint 3032 Series Installation Manual
OBERON 1012-00 Installation Manual
OBERON 1013-00 Installation Manual
OBERON 1042-MIST43 Installation Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine