All Rights reserved, including possible patents or trademarks. Documents shall not be provided to a third party or duplicated in any form without prior written permission.This document is not managed.1ASSEMBLY INSTRUCTIONODU AMC® & ODU AMC® Easy-Clean1. Cable assemblySize max. cable mm0 5.51 6.51.5 8.02 10.03 11.54.5 17.5Plug Crimp sleeveCrimp adapter Note! Cable with foil shield such as foiled twistedpair-cable (FTP) not suitable for shield terminationmentioned below.1. Slide crimp sleeve and crimp adapter over thecable. The crimp sleeve is not needed if a metalband is used for fastening the shield to the crimpadapter.2. Strip the cable and conductors (page 2). Foldback the shield and use fastening tape to fastenit temporarily to the cable jacket. Tin-plate thiswires if needed.3. Solder the wires, noting the placement of eachwire according to your wiring chart. Clean thesolder area with Isopropylalcohol and brush.4. Screw the crimp adapter on so that it is flush,observing torque values. Secure the screwthread with adhesive. The assembly toolsshould be used to counter the torque.(see page 3)5. Remove the fastening tape and lay the shieldbraid on to the crimp adapter.6. Fasten the shield braid to the crimp adapter bymeans of crimping or by using a metal band.More information. (see page 4) Pour pottingcompound into the connection area7. Bend relief: This can be implemented by meansof overmolding or by using shrink boot.More information. (see page 5)ODU assembly toolAdhesiveSealing surfaceovermoldGeneral information: Illustrations only exemplary. Product may vary in appearance.1) Additional information for cable preparation etc. please see page 2 and followingNote: Images are examplesand may differ from theproduct.