Panasonic CZ-CAPE2 Installation And Service Instructions Manual
POWERCN309OP13P (Yellow)DC12VEP valveBalance valveIntake valveOutput valve5P (Black)Indoor control PCBSignal output cables(short)(Supplied part ③)CN813WAY Optional partsSolenoid valvekit or gas pipevalve kitCN002POWER3P (White)[AC Power Input]CN001OPTION/3WAY6P (White)CN0039P (Red)[Solenoid valve output]Protective ground screwProtective ground screwProtective ground screwSolenoid valve control PCBOptional board boxIndoor unitPower cables (2 core) (Supplied part ②)Models where installation is possible in indoor unit electrical boxPOWERCN309OP13P (Yellow)DC12VEP valveBalance valveIntake valveOutput valve5P (Black)Indoor control PCBSignal output cables(long)(Supplied part ③)CN813WAY Optional partsSolenoid valvekit or gas pipevalve kitCN002POWER3P (White)[AC Power Input]CN001OPTION/3WAY6P (White)CN0039P (Red)[Solenoid valve output]Protective ground screwProtective ground screwProtective ground screwSolenoid valve control PCBOptional board boxIndoor unitPower cables (3 core) (Supplied part ②)Normal installationSolenoid Valve Installation (Electric) and Service Instructions1. Safety Precautions 3. Wiring DiagramThe connected solenoid valve is a solenoid valve kit, or a gas pipe valve kit.Controller(CZ-CAPE2)Optional board boxscrews 4x10 (2 locations)OPTION/3WAY(CN001)6P WhitePOWER(CN002)3P White6P Whitescrew 4x45P BlackCN0039P RedSpacers (4 locations)Optional parts9P RedSolenoid valvekit or gas pipevalve kitProtective ground screwfor power cable (3 core)Protective ground screwfor solenoid valve kit or gas pipe valve kit4. Installation ProceduresNote: See the reverse side for procedures for installation on various indoor units.Models where installation is possible in indoor unit electrical box1. Install the spacers for the solenoid valve control PCB in the electrical box.2. Wire according to the following procedure.3. When you have finished wiring work, check to be sure that there are no nipped portions in the wiring.Connect the 3P white connector of power cable(2 core) (Supplied part ②) to POWER (CN002) onthe solenoid valve control PCB.Connect the 3P yellow connector to OP1 (CN309) on the indoor control PCB.Connect the 6P white connector of Signal output cable (the short cable) (Supplied part ③) to OPTION/3WAY (CN001) onthe solenoid valve control PCB.Connect the 5P black connector to 3WAY (CN81) on the indoor control PCB.Connect the connector from the solenoid valve kit or gas pipe valve kit (9P red) to the 9P red connector (CN003) on the solenoid valvecontrol PCB.Connect the ground wire of the solenoid valve kit or gas pipe valve kit to the indoor unitusing the screw and washer (supplied part ⑦).* For the connecting location, refer to the indoor unit installation instructions.Power cable (2 core) (Supplied part ②)3P YellowTo indoor control PCBOP1(CN309)3P WhiteSignal output cable (short cable) (Supplied part ③)5P BlackTo indoor control PCB3WAY (CN81)6P WhiteCN0039P RedOPTION/3WAY(CN001)6P WhitePOWER(CN002)3P WhiteOptional partsSolenoid valvekit or gas pipevalve kit9P Red① Solenoid Valve Control PCB⑧ Nylon clamp(F7,F14)3P Yellow 3P White③ Signal output cables(long/short)5P Black 6P White② Power cables (3 core/2 core)3P Yellow 3P White⑤ Fastening screwsScrew 4x4-2 (1 pc.)Screw 4x10-2 (2 pcs.)④ Optional board box⑦ Protective ground screwfor indoor unitScrew 4x8-3Washer⑥ Cable tie (4 pcs.)Connect to the indoor control PCB with power cable(2 core/3 core) (Supplied part ②) and Signal output cable (Supplied part ③)Signal output cable (long/short) (Supplied part ③)3P Yellow3P WhitePower cable (3 core/2 core) (Supplied part ②)The following is intended for the person responsible for installing or servicing the Solenoid ValveController. Before conducting installation or electrical work, be sure to carefully read these“Safety Precautions”. Follow instructions exactly in all installation or electrical work.The precautions given in this manual consist of specific “Warnings” and “Cautions”. They provideimportant safety related information and are important for your safety, the safety of others, andtroublefree operation of the system. Be sure to strictly observe all safety procedures. The labels andtheir meanings are as described below.This symbol refers to a hazard or unsafe procedure or practice which can result insevere personal injury or death.WarningCaution This symbol refers to a hazard or unsafe procedure or practice which can result inpersonal injury or product or property damage.WarningBe sure to arrange installation at the dealer where the system was purchased or use a professionalinstaller.Leaks, electric shock or fire may result if an inexperienced person performs any installation or wiringBe sure to turn off the power source circuit breaker of the unit before installation or wiring.High electrical voltages used in the unit may cause electric shock.procedures incorrectly.Only a qualified electrician should attempt to install this system, in accordance with the provisions ofthe Technical standards for Electrical Installations, local regulations for indoor wirings and these“Installation (Electric) and Service Instructions”. Be sure to use a dedicated electrical circuit.Insufficient electrical circuit capacity may cause electric shock or fire.Use the specified cables (type and wiring diameter) for the electrical connections, and securely connectthe cables. Run and fasten the cables securely so that external forces or pressure placed on the cableswill not be transmitted to the connection terminals. Overheating or fire may result if connections orattachments are not secure.Install in a location that is fully strong enough to support the weight of the unit. If it is not strong enough,the unit may fall, resulting in injury.Ventilate the work area if cooling gas leaks during installation. Poisonous gas can result if cooling gascomes into contact with fire.After installation, check to be sure that there are no gas leaks.Poisonous gas can result if cooling gas leaks into the room and comes into contact with a fan heater,stove, range, or other source of fire.CautionDo not install in a location subject to leakage of flammable gasses.Fire can result if gas builds up around the unit.2. Supplied Parts1. Install the solenoid valve control PCB in the optional board box with the following procedure.2. Wire according to the following procedure.3. When you have finished wiring work, secure the cover of the optional board box with the supplied screw (4x4)Install the board spacers in the holes in the base of the optional board box.Note: When you do so, be careful of the direction of the solenoid valve conrol PCB(see following figure).Attach the optional board box to the unit with the supplied screws(4x10).Models without space inside electrical boxConnect the 3P yellow connector of power cable (Supplied part ②) to OP1 (CN309) on the indoor control PCB.Connect the 5P black connector of signal output cable (Supplied part ③) to 3WAY (CN81) on the indoor control PCB.Connect the ground wire of the power cables (3 core) to the indoor unit using the screw and washer (supplied part ⑦).* For the connecting location, refer to the indoor unit installation instructions.* When you use the power cables (2 core) for installing inside electrical box, ground connection is unnecessary.Connect the ground wires of the power cables and solenoid valve kit or gas pipe valve kit to the optional board box.* When you use the power cables (2 core), only connect the ground wire of the solenoid valve kit or gas pipe valve kit.Connect the 3P white connector of power cable(Supplied part ②) to POWER(CN002) on thesolenoid valve control PCB.Connect the 6P white connector of signal output cable(Supplied part ③) to OPTION/3WAY(CN001) on thesolenoid valve control PCB.Connect the connector from the solenoid valve kit or gas pipe valve kit (9P red) to the 9P red connector (CN003) on thesolenoid valve control PCB.Fasten the wires to the optional board box with the cable ties (supplied part ⑥)Note: When you do so, check to be sure that there are no nipped portions in the wiring.Use the long cables and 3 core cableswhen the solenoid valve controller isinstalled outside the indoor unit.Printed in Japan 85464369377012To indoor control PCBOP1(CN309)To indoor control PCB3WAY (CN81) |
Related manuals for Panasonic CZ-CAPE2
Panasonic CZ-CAPEK2 Installation And Service Instructions Manual
Panasonic CZ-ANC3 Installation Instructions Manual
Panasonic CZ-ANC2 Installation Instructions Manual
Panasonic CZ-RWS3 Installation Instructions Manual
Panasonic CZ-64ESMC3 Installation Instructions Manual
Panasonic CZ-64ESMC3 Installation Instructions Manual
Panasonic CZ-256ESMC2U Installation Instructions Manual
Panasonic CZ-ANC2 Instruction Manual
Panasonic FV-SW20VEC1 Installation And Operating Instructions Manual
Panasonic CZ-RE2C2 Installation Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine