Panasonic DP-M Series Instruction Manual
Also see for DP-M Series: Instruction manual
Thank you very much for purchasing Panasonic products. Pleaseread this Instruction Manual carefully and thoroughly for thecorrect and optimum use of this product. Kindly keep this manualin a convenient place for quick reference.SPECIFICATIONS1Indicators12 to 24V DC % Ripple P-P 10% or less+10-15ItemType of pressureModel No. DP-M2 DP-M2AType Standard With analog current output50mA or less 75mA or lessDifferential pressureRated pressure range 0 to 2.00 kPa.D {0 to 204 mmH 2 O.D}Hysteresis 0.01 kPa.D {1mm H 2 O.D}Repeatability Within s1% F.S.Displayablepressure range -0.05 to 2.10 kPa.D {-5 to 210 mmH2 O.D}Operation Orange LED (lights up when the comparative output is ON)Pressure unit Red LED (The indicator corresponding to the selected unitlights up during the sensing mode.)M1 setting Red LED (blinks in the M1 setting mode)M2 setting Red LED (blinks in the M2 setting mode)Response time 10ms or lessShort-circuit protection IncorporatedSet pressure range 0 to 2.00 kPa.D {0 to 204 mmH 2 O.D}Setting resolution 0.01 kPa.D {1 mmH 2 O.D}Pressure withstandability 6 kPa.D {612 mmH 2 O.D}Applicable fluid Non-corrosive gasDisplay 3 digit red LED display (Sampling rate: 4 times/sec. approx.)Comparative outputNPN open-collector transistor࣭Maximum sink current: 100mA࣭Applied voltage: 30V DC or less(between comparative output and 0V)࣭Residual voltage: 1V or less (at 100mA sink current)0.4V or less (at 16mA sink current)Output operationSupply voltageAmbient temperature 0 to +50Υ (No dew condensation), Storage: -10 to +60ΥAmbient humidity 35 to 85% RH, Storage: 35 to 85% RHPressure port ȭ4.6mm resin pipeWeight 75g approx.Temperature characteristics Over ambient temperature range 0 to +50Υ:within s3% F.S. of detected pressure at 25ΥMaterial Front case: ABS, Rear case: ABSLED display: Acrylic, Pressure port: PACable 0.18mm 2 3-core oil resistantcabtyre cable, 2m long0.18mm 2 4-core oil resistantcabtyre cable, 2m longCurrent consumption㸫Analog current outputSelectable either Normally open (NO) or Normally closed(NC) by the keys.Refer to 'ࠉࠉSETTING' [Output mode and outputoperation] for more details.8Output current: 4 to 20mA0 to 1.96 kPa.D{0 to 200 mmH2O.D}Zero-point: Within 4mA s1% F.S.Span: Within 16mA s3% F.S.Linearity: Within s1% F.S.Load resistance: 0 to 250ȐMJE-DPM No.0050-31VPIPING3Recommended tubeNotes: 1)2)3)TYGON is registered trademarks of SAINT-GOBAIN.Ensure that excessive pressure is not applied to the pressure ports. Since thissensor is designed for detecting small pressures, if excessive pressure or shockis applied to the pressure ports, the diaphragm (pressure sensing device) in thesensor may get damaged.Please do not compress the tube. If the tube is compressed, pressure exceedingthe rated value may be generated, damaging the diaphragm (pressure sensingdevice).Pressure Hi-portFix tubes on ports securelyPressure Lo-port Flexible tubes(silicone tube etc.)࣭TYGON tube, size: internal dia 4mm, external dia 6mm, madeby SAINT-GOBAIN.Not goodەەApply higher pressure to the Hi-port and lower pressure to theLo-port.Use flexible tubes (silicone tube etc.) that can fit the pressureports, ȭ4.6mm in diameter. The tubes should cover more thanhalf the length of the pressure ports.ەەەNever use this product as a sensing device forpersonnel protection.In case of using sensing devices for personnel protec-tion, use products which meet laws and standards,such as OSHA, ANSI or IEC etc., for personnelprotection applicable in each region or country.In case this sensor is used within Japan, SI unitmust be used since use of pressure units in Japanis restricted to SI units.WARNINGCAUTIONS2ەەەەەەەەەەەەەەەThis product has been developed / produced for industrial useonly.Use within the rated pressure range.Make sure that the power supply is off while wiring.Take care that wrong wiring will damage the sensor.Verify that the supply voltage variation is within the rating.If power is supplied from a commercial switching regulator,ensure that the frame ground (F.G.) terminal of the power supplyis connected to an actual ground.In case noise generating equipment (switching regulator, invertermotor, etc.) is used in the vicinity of this sensor, connect theframe ground (F.G.) terminal of the equipment to an actualground.Do not use during the initial transient time (0.5 sec.) after thepower supply is switched on.Do not run the wires together with high-voltage lines or powerlines or put them in the same raceway. This can cause malfunc-tion due to induction.Avoid dust, dirt, and steam.Take care that the sensor does not come in contact with water,oil, grease, organic solvents, such as, thinner etc., or strongacid, and alkaline.Do not insert wires, etc, into the pressure port. The diaphragm(pressure sensing device) will get damaged and correct opera-tion shall not be maintained.Do not operate the keys with pointed or sharp objects.Make sure that stress by forcible bend or pulling is not applieddirectly to the sensor cable joint.Extension up to total 100m is possible with 0.3mm 2 , or more,cable. However, in case of using this product as a CE conformityproduct, the power wire connected to this product must be within10m.DP-M series is designed for use with non-corrosive gas. It cannotbe used for liquid or corrosive gas.LED Display࣭ Digital Differential Pressure SensorDP-M Series For use outside JapanINSTRUCTION MANUAL |
Related manuals for Panasonic DP-M Series
Panasonic PLCD8C Instruction Manual
Panasonic SF2H Series Operating Instructions Manual
Panasonic PLCD20P Instruction Manual
Panasonic PLCD15V Instruction Manual
Panasonic PLCD24HD Instruction Manual
Panasonic PLCD42HD Instruction Manual
Panasonic Pro AV Series Operating Instructions Manual
Panasonic CF-VDW Series Supplementary Instructions Manual
Panasonic TX-1703MA Series Operating Instructions Manual
Panasonic TX-1703MA Series Operating Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine