Panasonic SC-GU3-02 Instruction Manual
INSTRUCTION MANUALCommunication Unit for DeviceNet SC-GU3-02CMJE-SCGU302 No.0065-60VFor details of the communication commands etc. of the communication unit forDeviceNet SC-GU3-02, refer to “Product Specification” or “CommunicationCommand Specification.”1 CE MARKED PRODUCT● The models listed under “ 8 SPECIFICATIONS” come with CE Marking.As for all other models, please contact our office.2 OUTLINE● Communication unit SC-GU3-02 can output the output signal (in case of 2-out-put type, only the output 1) of a sensor amplifier (NPN output type) that is con-nectable to cascading connector unit SC-71 (optional), as the communicationdata of DeviceNet.● SC-GU3-02 enables to connect max. 16 units of sensor amplifier (FX-300 se-ries or LS-400 series, etc.). In case of FX-500 series or LS-500 series, max.12 units of sensor amplifier can be connected.● This product can output all the output signals of the connected sensor amplifi-ers to PLC (Programmable Logic Controller) etc. in one time.● By using end unit SC-GU3-EU, settings and control of the connected optically com-municationable sensor amplifier (FX-500 series or LS-500 series) can be done.Sensor amplifier (Optional)End unit SC-GU3-EU (Optional)End plate MS-DIN-E(Optional)Cascading connector unitSC-71 (Optional)End plate MS-DIN-E(Optional)Communication unit for DeviceNet SC-GU3-023 FUNCTIONAL DESCRIPTION● Communication unit for DeviceNet SC-GU3-028. Power indicator (Green) 9. ERR. indicator (Red)10. Memory functionindicator (Yellow)4. Operation mode setting switch12. wire-savingconnector11. Connectorfor DeviceNet15. paralleloutputconnector(with cover)5. Setting extension key1. Address setting switch (Tens digit) 2. Address setting switch (One digit)3. Baud rate setting switch6. MS indicator (Green/Red)7. NS indicator (Green/Red)● End unit SC-GU3-EU8. Power indicator (Green)Designation Function1Address setting switch(Tens digit) (Note 3)(Factory setting is 0) To set address of DeviceNet.Setting is possible in the range of 0to 63 (64 or more: Error)Setting direction ofswitch(Present setting is 0)As for number displays on switches,refer to each switch.2Address setting switch(One digit) (Note 3)(Factory setting is 1)3Baud rate setting switch(Note 3)(Factory setting is 500kbps)To set baud rate of DeviceNet(bps) from 125K, 250K or 500K4Operation mode settingswitch (with cover)Factory setting issimple modeData amount of I/O message can be changed by this setting.DIP switch Operation mode Occupied memoryIN OUTStandard mode 3 byte 0 byteSimple mode 10 byte 10 byteFull mode 10 byte 44 byteMinimum mode 2 byte 0 byte5 Setting extension key(Note 3)Used for memory function (Note 1), teaching and light intensity adjustment(Note 2). Also, used for canceling communication error.6 MS indicator (Green/Red)Displays whether this product is operating properly or not• Green LED lights up: Normal operation condition• Lights off: Power OFFFor the detail of the error, refer to “ 7 ERROR INDICATOR”.7 NS indicator (Green/Red)Displays whether this product is communicating properly with DeviceNet or not• Green LED lights up: Normal operation condition• Lights off: Power OFFFor the detail of the error, refer to “ 7 ERROR INDICATOR”.8 Power indicator (Green) Lights up when power is ON.9 ERR. indicator (Red) Blinks when an optical communication error occurs.10 Memory functionindicator (Yellow)Lights up when using memory function.Blinks when connecting a sensor amplifier whose set contents are differentfrom the ones that are storing in this product.Notes: 1) in case using the memory function, SC-GU3-EU is required. Refer to “Communication CommandSpecification” for detail of memory function.2) For the teaching and memory function, refer to “Communication Command Specification”.3) For changing the setting, use a flat-head screwdriver etc.Thank you very much for purchasing Panasonic products. Read this InstructionManual carefully and thoroughly for the correct and optimum use of this product.Kindly keep this manual in a convenient place for quick reference.WARNING● Never use this product in a device for personnel protection.● In case of using devices for personnel protection, use products which meetlaws and standards, such as OSHA, ANSI or IEC etc., for personnel protec-tion applicable in each region or country.Designation Function11 Connector forDeviceNetTerminal No. Description1 V- connecting terminal(2 systems for cascade wiring)2 CAN-L connecting terminal(2 systems for cascade wiring)3 Drain connecting terminal(2 systems for cascade wiring)4 CAN-H connecting terminal(2 systems for cascade wiring)5 V+ connecting terminal(2 systems for cascade wiring)12 Wire-savingconnector Connecting Wire-saving connector SC-71(optional) connected sensor amplifier.13Paralleloutputconnector(with cover)Description Description1 Signal 0 Output info for 1ch amplifier 11 Signal 10 Output info for 11ch amplifier2 Signal 1 Output info for 2ch amplifier 12 Signal 11 Output info for 12ch amplifier3 Signal 2 Output info for 3ch amplifier 13 Signal 12 Output info for 13ch amplifier4 Signal 3 Output info for 4ch amplifier 14 Signal 13 Output info for 14ch amplifier5 Signal 4 Output info for 5ch amplifier 15 Signal 14 Output info for 15ch amplifier6 Signal 5 Output info for 6ch amplifier 16 Signal 15 Output info for 16ch amplifier7 Signal 6 Output info for 7ch amplifier 17 Open Not used8 Signal 7 Output info for 8ch amplifier 18 Open Not used9 Signal 8 Output info for 9ch amplifier 19 V+ V+10 Signal 9 Output info for 10ch amplifier 20 V+ V+4 MOUNTING AND CONNECTIONHow to mount1. Fit the rear part of the mounting sec-tion of the unit on a DIN rail.2. Press down the rear part of the mount-ing section of the unit on the DIN railand fit the front part of the mountingsection to the DIN rail.How to remove1. Push the unit forward.2. Lift up the front part of the unit to re-move it.Note: Take care that if the front part is lifted without push-ing the unit forward, the hook on the rear portion ofthe mounting section is likely to break.How to connect● Be sure that the power supply is OFF while adding / removing units.● When the units are mounted in cascade, mount the end plates MS-DIN-E (optional)at the both ends of the units to hold them between the flat sides of the plates.● Up to maximum 16 sensor amplifiers can be connected in cascade. (In case ofFX-500 series or LS-500 series, up to maximum 12 sensor amplifiers can beconnected in cascade.)● In case two different models of sensor amplifier are mounted in cascade, besure to mount identical models together.● For the cautions of the sensor amplifiers, refer to the instruction manuals en-closed with the amplifiers.1. Mount communication unitSC-GU3-02 on DIN rail.When mounting, remove the endconnector cap which is attached tothe connector area.2. Mount cascading connector unit SC-71(optional) one by one on the DIN rail.And slide them to side of SC-GU3-02.3. Insert sensor amplifiers (optional) toSC-71.4. In case using end unit SC-GU3-EU(optional) , mount SC-GU3-EU onDIN rail. And slide it to side of thesensor amplifiers.Attach the end connector cap whichis removed in the step 1 to the con-nector area for cascading of the lastunit.21110987654312 20191711615141318CN-M20-C2(optional)For detail, refer to “product Specification”or |
Related manuals for Panasonic SC-GU3-02
Panasonic SC-GU1-485 Instruction Manual
Panasonic EtherCAT SC-GU3-03 Instruction Manual
Panasonic SC-HG1-ETC Instruction Manual
Panasonic SC-HG1-USB Instruction Manual
Panasonic SUNX SC-HG1-CEF Instruction Manual
Panasonic SL-VVMES2 Instruction Manual
Panasonic KX-NT700 Operating Instructions Manual
Panasonic WG-AV120 Operating Instructions Manual
Panasonic KXC-M7800 Operating Instructions Manual
Panasonic KXF-4T3C Operating Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine