Panasonic VL-SWD273 Quick Start Manual
Key Features• Highly Expandable:Up to 6 additional monitors can be connected to the main monitor using a combination of 7-inch wired monitors and 2.2-inch wireless monitors (However, themaximum possible number of 7-inch wired monitors is 3). In addition, PBX connectivity is also supported.• Wireless Monitor: Using the wireless monitor, check visitors and respond promptly from the living room, kitchen and elsewhere in the home even while youare doing something else. Up to 6 wireless monitors connectable. Max wireless range is 100 m with no obstacles. You can add on repeaters to expand the range.Up to 2 DECT repeaters connectable.• 7-inch Screen: The main monitor and extension monitor have a 7-inch wide screen that offers easy viewing of wide vertical and horizontal views.• Voice Change Function: This function makes woman’s voice (higher keys) sounds like a man’s (lower keys).• Electric Lock Release Support for Gate:The gate or door lock can be easily and quickly released using monitors (wired or wireless) from anywhere in the house.• Wide-Angle Camera: Wide-angle lens covers approximately 170 degrees horizontally and 115 degrees vertically.• Picture Recording Function: The main monitor and extension monitor can record doorphone images from up to 50 doorphone calls or monitoringsessions. (up to 8 still images per visitor/session)• Night Vision with LED lights (illumination lamp):Door station is equipped with LED lights (illumination lamp). It enables the colour display of visitors at a distance of about 50 cm at night.Wiring Schematic DiagramOptional AccessoriesWire type and lengthVL-SVD273:Wireless monitors sold separatelyWiring run Wire type*6Diameter Length (Max.)Doorphone –Main monitor –Extension monitor*7φ 0.65 mm 22 AWG 100 mφ 1.0 mm 18 AWG 130 mφ 0.5 mm CAT 5 50 mMain monitor –Power supply unitφ 0.65 mm 22 AWG 10 mφ 1.0 mm 18 AWG 20 mPower supply unit –AC power sourceφ 1.2 mm - φ 2.0 mm(17 AWG - 12 AWG) No requirementMain monitor – Electric lock *8 φ 0.5 mm - φ 1.2 mm(24 AWG - 17 AWG)According to the specificationof connected device.Doorphone – Electric lock*8 φ 0.5 mm - φ 1.2 mm(24 AWG - 17 AWG)According to the specificationof connected device.Main monitor – Connection devicefor option input (A contact)*8φ 0.5 mm - φ 1.2 mm(24 AWG - 17 AWG)According to the specificationof connected device.Main monitor – PBX φ 0.65 mm CAT 3 or 22 AWG 100 m*1 When you use an additional doorphone, the maximum number of the electric locks that can be connected to thedoorphone depends on the type of doorphone. Consult your dealer for further information.For VL-V554 users:- Make sure to only connect electric door locks to the S1/S2 terminals of the doorphones.*2 You can also connect an optional lobby station or Video Intercom System for Apartment Complexes.*3 Connection devices for option input (A contact) can be used when a VL-V900 and VL-V700 series Video Intercom Systemfor Apartment Complexes is used.- Make sure to connect emergency terminals to the IN1/IN2 terminals.- Make sure to connect doorbells to the IN3/IN4 terminals. A doorbell and doorphone 2 cannot be used together.*4 VL-MWD273BX/VL-MWD273ML models only*5 VL-SWD273AZ/VL-SVD273AZ/VL-MWD273AZ: Use only the supplied AC cable.*6 Type: Single-pair cable with outer sheath (jacket)Conductor: Copper solid• A certified power supply wiring has to be used with this equipment. The relevant national installation and/orequipment regulations shall be considered. A certified power supply wiring not lighter than ordinary polyvinylchloride flexible wiring according to IEC 60227 shall be used.*7 When an extension monitor is used, make sure that the total wiring length from the doorphone to the mainmonitor and then to the extension monitor, is within about 100 m.*8 When using an electric lock or a connection device for option input (A contact), select a device that meets thefollowing guidelines:• Electric lock connection terminal (S1/S2, S3/S4):- N/O dry closure contact- 30 V AC (1 A)/24 V DC (1 A) or lower• Connection device for option input (A contact) terminal (IN1/IN2/IN3/IN4):- Input method: No-voltage contact- Open-circuit voltage between terminals: DC 7 V or less- Detection definite time: 0.1 seconds or more- Short-circuit between terminals: 5 mA or less- Resistance value: make: 500 Ω or less, break: 15 KΩ or moreDoor Station(Doorphone)VL-V522L(Surface mount)D1 D2 S1 S2D1D2D3D4Ml-1Ml-2MO-1MO-2MO-3MO-4MO-5MO-6IN1IN2IN3IN4P1P212341920212256789101112131415161718S1S2S3S4Ml-1Ml-256Ml-1Ml-256Ml-1Ml-256NPNPNPNPNPNPNPNPNPNPD1 D2 S1 S224 V DCNP220-240 V AC*5*2*4MAIN MONITOREXTENSIONMONITOR 1EXTENSIONMONITOR 2EXTENSIONMONITOR 3Connection device foroption input (A contact)*3DOORPHONE 1 *1DOORPHONE 2 *1Terminal box(4-conductor wiring)PBXNP: Non-polarisedElectric lockElectric lockElectric lockPowersupplyPower supplyPower supplyPowersupplyElectric lockVL-SWD273VL-SVD273Wireless Video Intercom SystemDoor Station (Doorphone)CMOS 0.3 M pixelsVL-V555 (Surface mount)CMOS 1.0 M pixelsVL-V554 (Surface mount)VL-V554U (Flash mount)DECT RepeaterVL-FKD2Lobby StationUp to 20 mainmonitors canbe connected.WirelessMonitor Station(Sub monitor)VL-WD613Extension MonitorPOWER SUPPLY UNIT(Power source)VL-MWD273: 24 V DC Power supply unit (supplied)VL-MWD272: 220-240 V AC, 50/60 HzVL-MWD273VL-MWD272 |
Related manuals for Panasonic VL-MWD273AZ
Panasonic VL-SWD272 Quick Start Manual
Panasonic VL-SWD272 Quick Start Manual
Panasonic VL-SWD501BX Quick Start Manual
Panasonic VL-SWD501AZ Quick Start Manual
Panasonic VL-MV71 Quick Start Manual
Panasonic VL-SV74 Quick Start Manual
Panasonic VL-SV30 Quick Start Manual
Panasonic VL-SV71 Quick Start Manual
Panasonic VL-SV71 Quick Start Manual
Panasonic VL-SWD501UBX Quick Start Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine