QEED QA-TEMP Instruction Manual
01 2015UNIVERSAL TEMPERATURE CONVERTERI4 way isolated - RS485 MODBUS- Datalogger QA-TEMPUNIVERSAL TEMPERATURE CONVERTER4 way isolated - RS485 MODBUS- Datalogger QA-TEMPPowerFailRxTxDoutUSBOTGQA-TEMPQEEDAdvanced UNIVERSAL TEMPERATURE CONVERTER, USBconfigurable, DIN rail mounting, 4-way galvanically isolated,universal power supply AC/DC, Programmable alarm contact,RS485 Modbus.DATALOGGING via USB with pen drive stick memory anddownload storage data on excel importable files. RTC Real TimeClock integrated. RTD,TC and POTENTIOMETER CONVERTER.TemperatureSensorINPUTTEMPERATURE:RTD: Pt100, Pt500, Pt1000, Ni100. 2, 3 or 4 wire measure, automatic detection ofcable interruption.TC Types: J, K, R, S, T, B, E, N; automatic detection of cable interruption.POTENTIOMETER: from 1000 Ohm to 10 KOhm.RESISTANCE: resistance measurement 400ohm or 4000 ohm to 2, 3, 4 wires.OUTPUTCURRENT: 0...20mA programmable, max load resistance 600 ohm.VOLTAGE: 0...10V programmable, min load resistance 2 kohm.CONTACT ALARM: 5A 230Vac SPDT relay fully programmable by FACILE QA-TEMP.RS485 MODBUS: Bus connection on the base of module by adapter (option) oron terminals. Dip-switch for setting address and baudrate.1 09 2015Analog outputContact AlarmRS485 ModbusDATALOGGERPOWER SUPPLYRETRASMISSION OUTPUTPROTECTION INDEX10..40 Vdc, 20-28 Vac, 50-60 HzOn isolated analog output,ABSORPTION Maximum 2 VAIP2016 bit50-60 Hz< 100 ppm/°C-15...+65°C-40°C... +85°C0,1% F.S.Voltage and Current (impressed) programmable; Activeor Passive supply output 13 Vdc 30mA maxACCURACYRESOLUTIONREJECTIONTHERMAL STABILITY AT 25°CWORKING TEMPERATURESTORAGE TEMPERATUREISOLATION Input, analog and digital output,serial output RS485 and USB port, Power supply, are4-way galvanically isolated at 1,5kVOnTheGo port by Pen Drive stick memory. The softwareFACILE QA-TEMP (free of charge) allow you to configureLog, all conversion parameters, set contact alarm, setModbus address. RTC Real Time Clock integratedBy free software FACILE QA-TEMP to configure all of theconversion parameters like span, zero, alarm contact andlog via USB port or via RS485. Dip-switch for settingmodbus address and baudrateCONFIGURATIONEN61000-6-4/2006 + A1 2011;EN64000-6-2/2005; EN61010-1/201017,5 x 100 x 112 mm (terminals excluded)Up to 2000 m s.l.m.HUMIDITY 10...90% non condensingALTITUDEMOUNTINGRemovable terminals 5,08mmCONNECTIONSCE STANDARDSDIMENSIONSNon-volating memory. Log on USBDATA LOGGERDIN rail mounting with removableterminals, RS485 bus and Supply connection ready onthe base of module (connector not included, onrequest).ENGLISH |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine