1 TD-000358-00-BTD-000358-00-B*TD-000358-00*™Page Station Expander Quick Start GuideInstalling the PS-X Page Station ExpanderThe Q-Sys PS-X is mounted using a new construction, UL approved, 2-gangelectrical box. The mounting procedure for an old-construction 2-gang box isthe same, however not all old-construction boxes will work with the PS-X. Besure you verify the fit before installing the old-construction box in the wall.General Requirements• The PS-X must have access to a Cat 5e connection (RJ45 Class 2) to theassociated Q-Sys Page Station.• The PS-X must be mounted in a UL approved, 2-gang electrical box, in awall no less than 2.38” (60.5 mm) deep.• The PS-X should be mounted in a location where it will not be anobstruction to normal traffic.• The Cat 5e cable must be less than or equal to 100 meters.Mount the Mounting Bracket to a 2-Gang Electrical BoxThe electrical box should be installed in the wall, during construction, with theCat 5e cable pre-wired.Refer to Figure 1.1. Use four Mounting Bracket Screws (3) to secure the Mounting Bracket tothe 2-gang box.Mount the PS-X to the Mounting BracketRefer to Figure 1.1. Connect the Cat 5e cable (1) (with an RJ45 Class 2 connector) to the RJ45socket (3) on the back of the PS-X.2. Angle the top of the PS-X towards the wall and slide the two mounting tabs(4) into the mounting tab receptacles (5).3. Make sure the cable is not binding anywhere.4. Straighten the PS-X, pull slightly down, and push in on the bottom.5. Secure the PS-X to the Mounting Bracket with one counter sunk Phillipsscrew (5) inserted in the hole (6) in the PS-X microphone docking plate.— Figure 1 —12 3— Figure 2 —123 456 58