Queensgate NANOSCAN OP400 Quick Start Instructions
PLEASE READ THE INSTRUCTIONS BEFOREATTEMPTING TO USE THE NANOSCAN OP400 SYSTEMIDENTIFYING YOUR SYSTEM COMPONENTSINSTALLING YOUR SYSTEM• Save this manual as it contains important safety information and operating instructions.• Before using the system, please follow and adhere to all warnings, safety and operating instructions located on the productand in this user manual.• Do not expose the product to open flames, extreme hot or cold temperatures, water or moisture.• Do not allow objects to fall on or liquids to spill on the product.• Connect the AC power cord only to designated power sources as marked on the product.• Make sure the electrical cord is located so that it will not be subject to damage.• To reduce the risk of damage, unplug the product from the power source before connecting the components together.• DANGER - never alter the AC cord or plug. If the plug will not fit into the outlet, have a proper outlet installed by a qualifiedelectrician.• Use only the proper type of power supply cord set (provided with the system) for this unit.• Do not attempt to disassemble the product. Doing so will void the warranty. This product does not containconsumer serviceable components. Service should be performed by authorized service centers.NANOSCAN OP400 QUICK START INSTRUCTIONSThe standard NanoScan OP400 system consists of:(1) - NanoScan OP400 Piezo Objective Scanner(1) - NPC-D-6110 Controller and power supply(1) - Microscope Thread Adapte(1) - 1.3mm (0.05 inch) Hex Key + (1) tightening key(1) - Objective Lens Thread Adapter (optional)(1) - Objective Lens Spacers (optional)(1) - 9 pin gender changer for RS232C QG-0494-SK-200001(1) - USB Cable QGPA0096-SK-102 + (1) 1.2 metre BNC to BNCcable QGBNCCAB + (1) RS232C QG-0494-SK-200002(1) - USB stick containing manuals and test reportsNanoScan OP400 PiezoObjective ScannerGenderchanger forRS232Cwww.prior.comSTEP 1: Select the position for theOP400 on the nosepiece.STEP 2: Insert the microscope thread adapterusing the key provided. Insert parfocal spacerif other objectives are to be used.STEP 3: Connect the OP400 to thenosepiece. Tighten both grub screwswith the hex key.STEP 4: Insert the objective lens using theappropriate objective lens adapter. Note noadapter is necessary for M32. Otherobjectives can be inserted into the nose pieceusing option parfocal spacers.STEP 5: The OP400 unitis now properly installed.Please take care with the cabling. Under no circumstances use the cabling to hold the stage.ParfocalObjective SpacerTightening Key Objective LensThread AdapterMicroscopeThread Adapter |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine