ReliOn HEM-741CREL Instruction Manual
Also see for HEM-741CREL: Instruction manualUser manual
SAFETY INFORMATIONINTENDED USEThis monitor is designed to measure blood pressure and pulse rate of adults within therange of the designated arm cuff, following the directions provided in this instructionmanual. The monitor is designed for home use. Read the Safety Information in thisinstruction manual before using this monitor.To assure the correct use of the product, basic safety measures should always befollowed including the warnings and cautions listed in this instruction manual.OPERATING THE DEVICEContact your physician for specific information about your blood pressure.Self-diagnosis and treatment using measured results may be dangerous. Follow theinstructions of your physician or licensed healthcare provider.DO NOT adjust medication based on measurement results from this blood pressuremonitor. Take medication as prescribed by your physician. Only a physician isqualified to diagnose and treat High Blood Pressure.The monitor is not intended to be a diagnostic device.If battery fluid should get in your eyes, immediately rinse with plenty of cleanwater. Contact a physician immediately.Read all of the information in the instruction manual and any other literature in thebox before operating the unit.Do not use this device on infants or persons who cannot express their intentions.Read the Special Conditions section of the instruction manual if your systolicpressure is known to be more than 220 mmHg. Inflating to a higher pressure thannecessary may result in bruising where the cuff is applied.Operate the device only as intended. Do not use the device for any other purpose.Dispose of the device, components and optional accessories according to applicablelocal regulations. Unlawful disposal may cause environmental pollution.Do not use a cellular phone near the device. It may result in an operational failure.Use only authorized parts and accessories. Parts and accessories not approved foruse with the device may damage the unit.Use only 1.5V Alkaline batteries with this device. Other types of batteries maydamage the unit.Do not use in a location with moisture, or a location where water may splash on theunit.CARE AND MAINTENANCEDo not subject the monitor to strong shocks, such as dropping the unit on the floor.Do not submerge the device or any of the components in water.Store the device and the components in a clean, safe location.Changes or modification not approved by the manufacturer will void the userwarranty. Do not disassemble or attempt to repair the unit or components.SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUALWARNING Indicates a potentially hazardous situation which, if not avoided,could result in death or serious injury.CAUTIONIndicates a potentially hazardous situation which, if not avoided,may result in minor or moderate injury to the user or patient ordamage to the equipment or other property.INSTRUCTION MANUALAutomaticBlood Pressure MonitorModel HEM-741CRELINTRODUCTIONThank you for purchasing the ReliOn® HEM-741CREL Automatic Blood PressureMonitor.Your new blood pressure monitor uses the oscillometric method of blood pressuremeasurement. This means the monitor detects your blood’s movement through yourbrachial artery and converts the movements into a digital reading. An oscillometricmonitor does not need a stethoscope so the monitor is simple to use.The HEM-741CREL comes with the following components:• Monitor • Wide Range Cuff • 4 “AA” Alkaline Batteries• Instruction Manual printed in English and Spanish • Quick Start GuidePlease read this instruction manual thoroughly before using the unit.Please keep for future reference.For specific information about your own blood pressure, CONSULT YOURDOCTOR.Fill in for future reference.DATE PURCHASED: __________________SERIAL NUMBER: ____________________• Staple your purchase receipt hereSAVE THESE INSTRUCTIONS5339081-6BLIMITED WARRANTYYour ReliOn® HEM-741CREL Automatic Blood Pressure Monitor, excluding the armcuff and batteries, is warranted to be free from defects in materials and workmanshipappearing within 5 years from the date of purchase, when used in accordance with theinstructions provided with the monitor. The arm cuff is warranted to be free fromdefects in materials and workmanship appearing within one year from the date ofpurchase when the monitor is used in accordance with the instructions provided withthe monitor. The above warranties extend only to the original retail purchaser.We will, at our option, repair or replace without charge any monitor or arm cuffcovered by the above warranties. Repair or replacement is our only responsibility andyour only remedy under the above warranties.To obtain warranty service contact Customer Service by calling 1-800-634-4350 for theaddress of Inspection center.Enclose the Proof of Purchase. Include a letter, with your name, address, phonenumber, and description of the specific problem. Pack the product carefully to preventdamage in transit. Because of possible loss in transit, we recommend insuring theproduct with return receipt requested.THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON INCONNECTION WITH THIS PRODUCT, AND OMRON HEREBY DISCLAIMSANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING IMPLIEDWARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULARPURPOSE. IMPLIED WARRANTIES AND OTHER TERMS THAT MAY BEIMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION TO THE PERIODOF THE ABOVE EXPRESS WARRANTY.OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHERSPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT COSTS,EXPENSES OR DAMAGES.This warranty provides you with specific legal rights, and you may have other rightsthat vary by jurisdiction. Because of special local requirements, some of the abovelimitations and exclusions may not apply to you.FOR CUSTOMER SERVICEVisit our web site at: www.omronhealthcare.comCall toll free: 1-800-634-4350Note:POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)This product has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to part 15 of the FCC rules.These limits are designed to provide reasonable protection against harmful interferencein a residential installation. The product generates, uses, and can radiate radiofrequency energy and, if not installed and used in accordance with the instructions,may cause harmful interference to radio communications. However, there is noguarantee that interference will not occur in a particular installation. If the product doescause harmful interference to radio or television reception, which can be determined byturning the product on and off, the user is encouraged to try to correct the interferenceby one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the product and the receiver.• Connect the product into an outlet on a circuit different from that to which thereceiver is connected.• Consult the dealer or an experienced radio/TV technician for help.POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only)This digital apparatus does not exceed the Class B limits for radio noise emissionsfrom digital apparatus as set out in the interference-causing equipment standard entitled“Digital Apparatus”, ICES-003 of the Canadian Department of Communications.Cet appareil numérique respecte les limites de bruits radioeléctriques applicables auxappareils numériques de Clase B prescrites dans la norme sur le materiel brouilleur:“Appareils Numériques”, ICES-003 édictée par le minister des communications.Changes or modifications not expressly approved by the party responsible forcompliance could void the user’s authority to operate the equipment.SPECIFICATIONSModel:Display:Measurement Range:Accuracy/Calibration:Inflation:Deflation:Rapid Air Release:Measurement Method:Power Source:Battery Life:Operating Temperature/Humidity:Storage Temperature/Humidity/Air Pressure:Main Unit Weight:Main Unit Dimensions:Cuff Size:Cuff Circumference:Memory:Contents:Optional Accessories:HEM-741CRELN3 (HEM-8720-WM)LCD Digital DisplayPressure: 0 to 299 mmHg, Pulse: 40 to 180/min.Pressure: ±3mmHg or 2% of readingPulse: ±5% of readingAutomatic by electric pumpAutomatic pressure release valveAutomatic exhaust valveOscillometric method1.5V 4 "AA" batteriesApprox. 300 uses with 4 new alkaline batteries50ºF to 104ºF (10ºC to 40ºC) /15 to 90% RH-4ºF to 140ºF (-20ºC to 60ºC) /10 to 95% RH700-1060 hPaApproximately 11 1/4 oz. (319g)not including batteriesApprox. 6"(l) × 4 7/8"(w) × 3 1/2" (h)(152 mm × 123 mm × 88 mm)Approx. 6"(w) × 22 1/8"(l) (151 mm × 563 mm)Cuff tube 35 3/8" (900 mm)Fits arm circumferences 9" to 17"(220 mm to 420 mm)Up to 30 readings per userMain Unit, Wide Range Cuff, 4 "AA" Alkaline Batteries,Instruction Manual, and Quick Start GuideWide Range Cuff 9'' - 17'' (220mm - 420mm)NOTE: These specifications are subject to change without notice.Manufactured for OMRON HEALTHCARE Co., Ltd.Made in ChinaDistributed by OMRON HEALTHCARE, INC.1925 West Field CourtLake Forest, IL 60045 U.S.A.www.omronhealthcare.com© 2012 OMRON HEALTHCARE, INC.ReliOn® is a registered trademark used under license by OMRON HEALTHCARE,INC..................................................................Distributed by:Wal-Mart® Stores, Inc.Bentonville, AR 72716FCC STATEMENTHEM-8720-WM_B_M02_120913.pdfSETTING THE DATE AND TIMEWARNINGIf battery fluid should get in your eyes, immediately rinse withplenty of clean water. Contact a physician immediately.CAUTIONRead all of the information in the instruction manual and any otherliterature in the box before operating the unit.CAUTIONThis device is intended for use in measuring blood pressure andpulse rate in the adult population. Do not use this device on infantsor persons who cannot express their intentions.APPLYING THE CUFF ON THE LEFT ARM1. Make sure the air plug is securely insertedin the main unit.2. Remove tight-fitting clothing from your upperarm.3. Apply the cuff to your left upper arm sothe arrow is centered on the inside of your armand aligned with your middle finger.The air tube runs down the inside of your arm.The bottom of the cuff should beapproximately 1/2 " above your elbow.4. Wrap the cuff firmly in place around yourarm using the cloth fastening.APPLYING THE CUFF ON THE RIGHT ARMWhen taking a measurement using the right arm, use this instruction for Step 3.Apply the cuff to your right upper arm sothe arrow and the air tube runs along the insideof your arm. The bottom of the cuff should beapproximately 1/2 " above your elbow.NOTE: Be careful not to rest your arm on the air tube. This will restrict the flow of airto the cuff.APPLYING THE ARM CUFF1/2 inch (1 - 2 cm)Air TubeArrowLeft ArmRight ArmArrowTAKING A MEASUREMENTThe monitor is designed to store the blood pressure and the pulse rate in the memoryfor two people (USER A or USER B) every time a measurement is completed.1. Sit on a chair with your feet flat on the floor.Place your arm on a table so the cuff is levelwith your heart.Keep still and do not talk during measurement.2. Select your USER ID (A or B).3. Press the ON/OFF button. All symbols appear on the display.The cuff starts to inflate automatically. As the cuff inflates, the monitor automaticallydetermines your ideal inflation level.Remain still and do not move your arm until the entire measurement process is completed.NOTE: To stop the inflation or measurement, push the ON/OFF button. Themonitor will stop inflating, start deflating, and will turn off.4. Inflation stops automatically and the measurement is started.As the cuff deflates, decreasing numbers appear on the display and the HeartbeatSymbol ( ) flashes.5. When the measurement is complete, the arm cuff completelydeflates. Your blood pressure and pulse rate are displayed.The 1999 WHO/ISH guidelines for the management of hypertension are as follows:This is a general guideline because blood pressure depends on age and morbidity.A lower home blood pressure goal may be recommended for certain patients,including diabetic patients, pregnant women, and patients with renal failure.6. Press the ON/OFF button to turn the monitor off.NOTE: The monitor will automatically turnoff after 2 minutes.CARE AND MAINTENANCETo keep your blood pressure monitor in the best condition and protect the unit fromdamage, follow the directions listed below:Do not forcefully bend the arm cuff or air tube. Do not fold tightly.Clean the monitor with a soft dry cloth.Do not use any abrasive or volatile cleaners.Do not attempt to clean the cuff.CAUTIONDo not submerge the device or any of the components in water. Donot subject the monitor to extreme hot or cold temperatures,humidity or direct sunlight.CAUTIONStore the device and the components in a clean, safe location.CAUTIONDo not subject the monitor to strong shocks, such as dropping the unit on the floor.Remove the batteries if the unit will not be used for three months or longer. Alwaysreplace all the batteries with new ones at the same time.Use the unit in a manner consistent with the instructions provided in this manual.CAUTIONUse only authorized parts and accessories. Parts and accessories notapproved for use with the device may damage the unit.CAUTIONChanges or modification not approved by the manufacturer will void the userwarranty. Do not disassemble or attempt to repair the unit or components.TROUBLESHOOTING TIPSPROBLEMNo power.No display appears on the unit.Measurement values appear toohigh or too low.CAUSES AND SOLUTIONSReplace all four batteries with new ones.Check the battery installation for proper placementof the battery polarities.Blood pressure varies constantly. Many factorsincluding stress, time of day, how you wrap thecuff, may affect your blood pressure.Review the sections “Before Taking aMeasurement” and “Taking a Measurement”.ERROR INDICATORS1. Press the hook on the top of the battery cover and lift thecover off in the direction of the arrow.2. Install 4 “AA” size batteries so the + (positive) and- (negative) polarities match the polarities ofthe battery compartment as indicated.3. Replace the battery cover.BATTERY REPLACEMENTLow Battery IndicatorWhen the Low Battery Indicator appears on the display, turn the monitor off andremove all the batteries. Replace with four new batteries at the same time. Long-lifealkaline batteries are recommended.NOTES: • Turn the unit off before replacing the batteries. If the batteries are removedwhile the unit is still on, the date and time will be reset to that of theprevious use. However, the measurement results are not deleted.• When the batteries are replaced, you may need to reset the date and time. If“-:--” appears on the display, refer to “Setting the Date and Time”.CAUTIONDispose of the device, components and optional accessories according toapplicable local regulations. Unlawful disposal may cause environmentalpollution.BATTERY INSTALLATIONUNIT DISPLAYKNOW YOUR UNITMain Unit:Components:SET buttonWide Range CuffAir tubeAir plug Quick StartGuideInstructionManual4 "AA" AlkalineBatteriesDISPLAY SYMBOLSIRREGULAR HEARTBEAT SYMBOL ( )When the monitor detects an irregular rhythm two or more times during themeasurement, the Irregular Heartbeat Symbol ( ) will appear on the display with themeasurement values.An irregular heartbeat rhythm is defined asa rhythm that varies by less than 25% fromthe average rhythm or 25% more than theaverage rhythm detected while the monitoris measuring the systolic and diastolicblood pressure.If the irregular heartbeat symbol ( )displays with your measurement results,we recommend you consult yourphysician. Follow the directions of yourdoctor.MOVEMENT ERROR SYMBOL ( )The Movement Error Symbol ( ) is displayed if you move your body during themeasurement. Please remove the arm cuff, and wait 2-3 minutes. Reapply the arm cuffand take another measurement.AVERAGE VALUE SYMBOL ( )The Average Value Symbol ( ) is displayed when you press the memory button.The most recent average reading appears on the display screen.HEARTBEAT SYMBOL ( )The Heartbeat symbol flashes on the display at every heartbeat during themeasurement.Normal HeartbeatIrregular HeartbeatShort LongBloodpressurePulsePulseBloodpressureUSING THE MEMORY FUNCTIONThe monitor automatically stores up to 30 sets of measurement values (blood pressureand pulse rate) for each user (A or B). When 30 sets of measurement values are stored,the oldest record is deleted to save the most recent values.AVERAGING FUNCTIONThe monitor calculates the average reading based on the three most recent sets ofmeasurement values taken within 10 minutes of the most recent reading.NOTES: • If two sets of measurement values are stored in the memory for the 10minutes period, the average is based on the two sets of measurementvalues. If one set of measurement values is stored, this is displayed as theaverage.• When viewing the reading taken without setting the date and time, "-:--" isdisplayed instead of the date and time.• The average reading will not be calculated without setting the date andtime.TO DISPLAY THE MEASUREMENT VALUES1. Select your USER ID (A or B).2. Press the Memory button ( ).The Average Symbol ( ) appears on the display when the averagereading is shown.3. Press the Down button ( ) to display the most recent set ofmeasurement values on the screen. The values are displayed from the mostrecent to the oldest.NOTES: • The Memory number appears fora second before the pulse rate isdisplayed. The newest set isnumber “1”.• The date and time are alternatelydisplayed with the measurementvalues.Press the Up ( ) or Down ( ) buttonto display the next set of values.NOTE: Press and hold the Up or Down button to display the values faster.TO DELETE ALL VALUES STORED IN THE MEMORYThe values stored in the memory are deleted by USER ID.You cannot partially delete values stored in the memory. All values forthe user you select will be deleted.1. Select your USER ID (A or B).2. While holding the Memory button ( ), press the ON/OFF button downfor more than 2 seconds until the display appears as it does in thefollowing illustration.3. Press the ON/OFF button to turn the monitor off.NOTE: The monitor will automatically turn off after 2 minutes.Set the monitor to the current date and time before taking a measurement for the firsttime.1. TO START THE SETTINGPress the SET button to adjustthe date and time.The year flashes on the display.2. SETTING THE YEARThe year can be set between 2013 and 2040. When thedisplay reaches 2040, it will return to 2013.Press the Up button ( ) to advance by one year.Press the SET button to set the current year.The month flashes on the display.NOTES: • Press the Down button ( ) to decrease thedate and time values.• Press and hold the button to increase ordecrease the date and time values faster.3. SETTING THE MONTHPress the Up button ( ) to advance by one month.Press the SET button to set the current month.The day flashes on the display.4. SETTING THE DAYPress the Up button ( ) to advance by one day.Press the SET button to set the current day.The hour flashes on the display.5. SETTING THE HOURThe time is set using AM or PM.Press the Up button ( ) to advance by one hour.Press the SET button to set the current hour.The minute flashes on the display.6. SETTING THE MINUTEPress the Up button ( ) to advance by one minute.Press the SET button to set the minute setting.7. TO TURN THE MONITOR OFFPress the ON/OFF button.NOTE: The monitor will automatically turn off 2 minutesafter the minute has been set.WARNINGContact your physician for specific information about your blood pressure.Self-diagnosis and treatment using measured results may be dangerous.Follow the instructions of your physician or licensed healthcare provider.WARNINGDO NOT adjust medication based on measurement results from this bloodpressure monitor. Take medication as prescribed by your physician. Only aphysician is qualified to diagnose and treat High Blood Pressure.WARNINGThe monitor is not intended to be a diagnostic device.SPECIAL CONDITIONSCAUTIONInflating to a higher pressure than necessary may result in bruising wherethe cuff is applied.If your systolic pressure is known to be more than 220 mmHg, press andhold the ON/OFF button until the monitor inflates 30 to 40 mmHg higherthan your expected systolic pressure, after the cuff starts to inflate.NOTES: • Do not apply more pressure than necessary.• The monitor will not inflate above 299 mmHg.When the measurement is complete, the arm cuff completely deflates.Your blood pressure and pulse rate are displayed. Air plug disconnected.Arm cuff not appliedcorrectly.Air is leaking from thearm cuff.Cuff over or underinflated.Device error.Batteries are worn.Movement duringmeasurement.Clothing is interferingwith the arm cuff.Insert the plug securely. Refer to“Applying the Arm Cuff”.Apply the arm cuff correctly. Refer to“Applying the Arm Cuff”.Do not inflate the cuff above 299 mmHg.Refer to “Taking a Measurement”.Remove any clothing interfering with thearm cuff. Refer to “Applying the ArmCuff”.Replace the four batteries.Refer to “Battery Installation”.Repeat measurement. Remain still and donot talk during measurement. Refer to“Taking a Measurement”.Repeat measurement. Remain still and donot talk during measurement. Refer to“Taking a Measurement”.If “E2” appears repeatedly, inflate the cuffmanually until it is 30 to 40 mmHg aboveyour previous measurement result. Referto “Taking a Measurement”.Replace the cuff with a new one.Contact Customer Service.The arm cuff was inflatedabove 299 mmHg wheninflating the cuff manually.SYMBOL CAUSE CORRECTIONON/OFF buttonMemory buttonUSER IDSelection SwitchUp/Down ( ) buttonsAir JackDisplay Battery compartment: to display the older readings: to display the recent readingsSystolic blood pressureDiastolic blood pressureMemory symbolAverage value symbolHeartbeat symbolIrregular heartbeat symbolUSER ID symbol (A/B)Blood pressure level indicatorPulse display and Memory numberDeflation symbolBattery low indicatorDate/Time DisplayMovement error symbolSystolic blood pressureHIGH above 139 mmHgPRE 130 - 139 mmHgNORM 129 mmHg or lessDiastolic blood pressureHIGH above 89 mmHgPRE 85 - 89 mmHgNORM 84 mmHg or lessAlternating displayBattery CoverBEFORE TAKING A MEASUREMENTTo ensure a reliable reading follow these recommendations:1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutesbefore taking a measurement. Rest for at least 15 minutes before taking themeasurement.2. Stress raises blood pressure. Avoid taking measurements during stressful times.3. Measurements should be taken in a quiet place.4. Remove tight-fitting clothing from your left arm.5. Sit on a chair with your feet flat on the floor. Rest your left arm on table so that thecuff is at the same level as your heart.6. Remain still and do not talk during the measurement.7. Wait 2-3 minutes between measurements. The wait time allows the arteries to returnto the condition prior to taking the blood pressure measurement. You may need toincrease the wait time depending on your individual physiological characteristics.8. Keep a record of your blood pressure and pulse readings for your physician. Asingle measurement does not provide an accurate indication of your true bloodpressure. You need to take and record several readings over a period of time. Try tomeasure your blood pressure at the same time each day for consistency.Category / Blood pressureHypertensionHigh-NormalNormalSystolic blood pressureabove 139 mmHg130 - 139 mmHg129 mmHg or lessDiastolic blood pressureabove 89 mmHg85 - 89 mmHg84 mmHg or lessINSTRUCTION MANUALAutomaticBlood Pressure MonitorModel HEM-741CRELINTRODUCTIONFill in for future reference.DATE PURCHASED: __________________SERIAL NUMBER: ____________________5339081-6BThank you for purchasing the ReliOn® HEM-741CREL Automatic Blood PressureMonitor.HEM-741CRELAutomaticBlood PressureMonitorBlood Pressure MonitorQuick Start Guide |
Related manuals for ReliOn HEM-741CREL
ReliOn HEM-741CREL Instruction Manual
ReliOn HEM-780REL Instruction Manual
ReliOn HEM-780REL Instruction Manual
ReliOn HEM-780REL Instruction Manual
ReliOn HEM-412CREL Instruction Manual
ReliOn HEM-412CREL Instruction Manual
ReliOn HEM-18SREL Instruction Manual
ReliOn 7400REL Instruction Manual
ReliOn 7100REL Instruction Manual
ReliOn HEM-741CREL User Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine