Taco TS-1P Installation & Operation Manual
www.taco-hvac.com | 800.962.3783QSTART-TS1PInstallation & Operation GuidePlease read this manual thoroughly to ensuresafe installation and proper operation.PrecautionsTo prevent injury and property damage, follow these instructions.Failure to adhere to installation/operation procedures and allapplicable codes may result in hazards as indicated by warningcodes outlined below:indicates an imminently hazardous situation which, if not avoided, willresult in death or serious injury. This signal word is to be limited to themost extreme situations.indicates a potentially hazardous situation which, if not avoided, couldresult in death or serious injury.indicates a potentially hazardous situation which, if not avoided, mayresult in minor or moderate injury. It may also be used to alert againstunsafe practices.This is the safety alert symbol. Read and follow instructions carefully toavoid a dangerous situation.This symbol alerts the user to the presence of “dangerous voltage”inside the product that might cause harm or electrical shock.DANGERWARNINGCAUTIONSafety InstructionsEquipment starts automatically. Lockout/tagout before servicing.As with all electrical products, read manual thoroughly. Only qualified,expert personnel should perform maintenance and installation. Contact thenearest authorized service facility for examination, repair, or adjustment.Do not disassemble or repair unit unless described in this manual; deathor injury to electrical shock or fire hazard may result. Specifications andmanual data subject to change. Consult factory for additional information.DANGERCAUTION1Ø AC Input 50/60 HzL1 L2T1 T2MVoltage InputAuto RunFaultOutputStatusOutputDry InputAuto RunNormally OpenInput12-120VAC/DCInputMain Power WiringWire main power input and output to the appropriate 12AWG wire leads utilizingproperly sized wire nuts. Use only copper conductors rated at least 60°C.Maintain proper clearances and verify that no possibility of an electrical shortexists between the power conductors or enclosure. Ensure that wires are notunder stress and all insulation is intact.Low Voltage WiringAutomation system control wiring should be run in a separate conduit. Thecontrol terminals accept 26~14AWG wire torqued to 3.5 in-lb.InstallationFAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN DEATH ORSERIOUS INJURYMountingMount the starter on a minimum 14 cu-in single gang junction box. To accessmounting holes, slide upper and lower covers to the open position.(See Figure 1)Using provided mounting screws (6-32 x 7/8”), attach starter housing to junctionbox (once appropriate wiring has been completed).• Do not locate starter in an environment subject to flammable gases, dusts ormaterials. Contact arcing can induce explosion or fire.• Install starter in UL Type 1 (NEMA 1) appropriate locations only. Safe mountingrequires a dry, protected environment.• The TS-1P is rated for maximum ambient temperature of 40°C• Do not allow any metal shavings or debris from installation to enter enclosure.DANGERWARNINGFigure 1HAZARDOUS VOLTAGE• Disconnect and lock out all power before installing or servicing equipment.• This equipment may require locking out multiple power sources prior to service• Install and wire in accordance with all applicable local & national electrical andconstruction codesT |
Related manuals for Taco T1P
Taco iWorX HPU2 Installation Manual
Taco iWorX HPU3 Installation Manual
Taco UCP-1 Application Manual
Taco iWorx UCP-1 Application Manual
Taco iWorx MPU2 Application Manual
Taco iWorx SMZ1 Application Manual
Taco PC702–1 Instruction Sheet
Taco 0034e Instruction Sheet
Taco PC705-2 Instruction Sheet
Taco 0034ePlus Instruction Sheet
manualsdatabase
Your AI-powered manual search engine