T&D RTR-505 User Manual
Also see for RTR-505: User manualUser manualUser manual
Continued on Back Page. >>Part Names2. Connecting an Input ModuleInsert the module into the module jack. Once the Unit recognizes the module, the LCD display will change as shownbelow and recording will start. (If you have purchased an RTR-505-P, the Unit has been ready for the pulse measure-ment by default, therefore recording will start upon installation of the battery.The factory default settings are as follows: Recording Interval at 10 minutes, Recording Start at Immediate Start, Recording Mode at Endless.Make sure that the module is completelyinserted until you hear a “click” sound.Set Model Number Measurement Items Input Module LCD Displayed Items (see the following section #3) Compatible SensorsRTR-505-TC Temperature Thermocouple Module (TCM-3010) Measurement, Unit of Measurement, Sensor Type,Operational StatusThermocouple: TypeK, J, T, SRTR-505-Pt Temperature PT Module (PTM-3010) Measurement, Unit of Measurement, Sensor Type,Operational Status Pt100, Pt1000RTR-505-V Voltage Voltage Module (VIM-3010) Measurement, Unit of Measurement, Operational Status Voltage Input SignalRTR-505-mA 4-20mA 4-20mA Module (AIM-3010) Measurement, Unit of Measurement, Operational Status 4-20mA Input SignalRTR-505-P Pulse Pulse Input Cable (PIC-3150) Measurement, Unit of Measurement, Operational Status - - - -1. Installing the BatteryCoverRubberPackingLithium Battery(inserted into tube)Screws1 Remove the screws and open the cover.Make sure to use the proper size and type of screwdriver. (Phillips head #1 screwdriver is recommended.)2 Insert the included battery.Do not remove the battery from its tube casing.- If using a CR2 lithium battery, the tube is not necessary.3 Check the rubber packing for any cuts or scratches and close the cover as it was whenopened.- Dust or defects on the packing can adversely affect the waterproof capacity; in this case, remove the dust or replace the pack-ing if it is damaged.- Be sure to completely close the cover.- Make sure not to over tighten the screws.(Appropriate Tightening Torque: 20N cm to 30N cm{2Kgf cm to 3Kgf cm})Notes about Battery Installation- After inserting the battery for the first time, nothing may appear or occur for about 10 seconds; this is not a malfunction.- If a new battery has been installed and nothing appears in the display, please remove and reinsert the battery.- When inserting a battery, make sure no water or foreign objects get inside the case.- Make sure that + and - are in the correct direction.About Lithium Batteries- Lithium batteries CR2 sold in stores may also be used, but if you are using in an environment below -20°C, above 60°C, or in asituation such as transportation where continued vibration is likely to occur, we strongly suggest the purchase and use of the ourlithium battery LS14250. (Please purchase the optional battery set TR-11P2 in which LS14250 is included.)- When using a LS14250 type lithium battery, even though a new battery has been inserted the battery warning mark may remainon for a short time. This is due to a special characteristic of the battery. Note that the longer the battery has been in storage thelonger the amount of time, from 10 minutes to about 1 hour, the battery warning mark will remain on. If during that time the BaseUnit is used to get the current status of the Remote Unit, the remaining battery level will show that the battery level is low.- Please store the lithium battery LS14250 in a place that is 20 °C or less.- When changing a CR2 battery, we strongly suggest changing the rubber packing and the drying agent. Please purchase themaintenance set TR-00P1 sold separately.RTR-505 is a Remote Unit. In order to use wirelesscommunication,it is necessary to purchase a Base Unitseparately. (Compatible Base Units: RTR-500, RTR-500NW,RTR-500AW)Wireless Data Recorder RTR-505 is referred to as the “Unit”in this manual.SpecificationsDevice Name RTR-505Measurement Items (*1) Temperature / Voltage / 4-20mA / PulseRecording Intervals Select from 15 choices: 1, 2, 5, 10, 15, 20, and 30 sec. / 1, 2, 5, 10,15, 20, 30, and 60 min.Logging Capacity 16,000 ReadingsRecording Start Method Immediate Start / Programmed StartRecording Mode Endless / One Time (Factory Default Setting: Endless)LCD Displayed ItemsMeasurement, Recording Status, Recording Mode, Battery LifeWarning, Unit of Measurement, Full (Logging Capacity FULL),Sensor Unconnected, Input Module Unconnected, MeasurementRange Exceeded, Display Range Exceeded)CommunicationInterfaces Wireless Communication / Optical CommunicationWireless CommunicationSpecificationsRF Power 7mWRadio StandardSpecificationsFCC Part15 Section247 / IC RSS-210Frequency Range : 902 to 928MHzTransmission Range About 150m (500ft) (if direct and unobstructed)CommunicationSpeed About 2 min. (when downloading 1 unit at full logging capacity)Optical CommunicationSpeedAbout 160 sec. (when downloading 1 unit at full logging capacity at2400bps)Power Lithium Battery (LS14250) / Lithium Battery (CR2) (*2)Battery Life (*3) About 10 months (for temperature measurement)Waterproof Capacity Splash proof (rated for use in daily life) (*4)Dimensions H62 W47 D19mm (excluding protrusions and sensor part)Weight About 55g (including battery / excluding input module)Operating TemperatureRangeUnit Temp Resistance: - 40 to 80 C(Unit temp resistance and measurement range is -40 to 80 C butwireless communication cannot occur in an environment of lessthan -30 C.)Other A Base Unit is required (sold separately).(Compatible Base Units: RTR-500, RTR-500NW, RTR-500AW)(*1) Measurement items other than Pulse will have different measurement range depending on the inputmodule and sensor to be connected. For details, see the User s Guide included with the inputmodule.(*2) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery setfor low-temperature use (TR-11P2) for replacement.(*3) Battery life varies depending upon the connected input module, measuring environment, frequencyof communication, Unit settings, and battery performance. For details, see "Estimated Battery Life"in this manual.(*4) Waterproof capacity of the Unit with an input module connected. Note that sensor connection of theinput module is not water resistant.Wireless Data RecorderRTR-505User’s ManualThank you for purchasing our product.Carefully read this instruction manual before using this Unit.T&D Corporationhttp://www.tandd.com/817-1 Shimadachi Matsumoto, Nagano 390-0852 JAPANFax:+81-263-40-3152© Copyright T&D Corporation. All rights reserved.This is printed using recycled paper. 2011.05 16504760001 (1st Edition)Outline of RTR-505External Input Module TypeSplash proof (rated for use in daily life)RTR-505 is a data logger designed to measure andrecord different items depending on the input module tobe connected: temperature (thermocouple/Pt), voltage,4-20mA, and pulse. The body is splash proof (rated foruse in daily life), which can be placed in an environmentbetween -40 and 80 C. Recorded data can beautomatically collected from the RTR-505 via wirelesscommunication with the Base Unit (sold separately), andalso viewed in graph and table form as well as printedout by using the supplied software.Package Contents:Data Logger (RTR-505), Tubed Lithium Battery (LS14250),Input Module(*), Strap, User's Manual (this manualincluding warranty)* An input module included in the package differsdepends upon which "set model" has been purchased.3. How to Read the LCD DisplayWhen being used in very hot or cold environments the display may become difficult to read. This is not a malfunction.Basic LCD Display[REC] Mark The recording status will appear.ON: Recording in progressBLINKING: Waiting for programmed start[ONETIME] Mark When the recording mode is set to "One Time", thismark will appear. The factory default setting is "End-less" and this mark will not appear.Battery WarningMarkWhen it is time for the battery to be replaced, thismark will appear.Measurements andMessages AreaMeasurements or operational messages will appearhere.Sensor Type Types of sensor connected or set to the Unit willappear.Thermocouple Sensor: K, J, T, SPlatinum Thermal Resistance Sensor: Pt (Pt100),PtK (Pt1000)Unit of Measurement The unit of measurement for the display will appear.Battery Replacement Sign1. When it is time for the battery to be replaced, a batterywarning mark will appear.Please replace the battery as soon as possible if thismark appears.2. If you do not change the battery and continue using theUnit, the measurement display will intermittentlydisplay [bAtt].- After this point the downloading of data can nolonger be done via wireless communication.- Without changing the battery and attempting to useoptical communication to download recorded data,the communication may be broken and if so allrecorded data may be lost.- Recording will be continued.3. If the battery is further left unchanged, the display willautomatically shut off.If, at this time, a new battery is placed in the Unit,[CHEC] will appear on the display after which record-ing will begin again using the previously set recordingconditions. Note however that all previously recordeddata will have been lost.Estimated Battery LifeWhen a battery warning mark appears, try to replace the battery with a newone as soon as possible.In a normal temperature environment, where recorded data is downloadedonce a day or if monitoring is carried out once every ten minutes:Set Model Number Recording Interval: 1secondRecording Interval: 10seconds or longerRTR-505-TC About 10 months About 10 monthsRTR-505-Pt About 10 months About 10 monthsRTR-505-V, RTR-505-mA About 10 months About 10 monthsRTR-505-P (Input: Open) About 20 months About 10 monthsRTR-505-P (Input: Short) About 20 months About 10 months- When the average reading recording function is enabled for the RTR-505-V or RTR-505-mA, the battery life will be the same as when the recording interval is onesecond regardless of the actual recording interval.- The battery warning mark may appear sooner than noted above.- Battery life will be shortened if used under the following conditions: downloadingdata very often, setting the recording interval at less than ten seconds, or measuringin an environment below -20 °C (-4 °F) or above 60 °C (140 °F).Notes about Changing the Battery- Before replacing a battery, please make sure to download any necessary data andproceed with changing the battery.- If + (plus) and – (minus) are mistaken, or if the battery terminals + and – are shorted,the recorded data that is stored in the Unit will be lost.- Downloading of data cannot occur while the battery is removed.Display Example for Each ModelDisplay varies on different models as shown below.RTR-505-TC (Thermocouple)Temperature measurement will be displayed. (Unit:°F / °C) Sensor type will be displayed under themeasurement; the factory default setting is Type K.By using the software included with the Base Unit,you can change the sensor type.RTR-505-Pt (Pt100 / Pt1000)Temperature measurement will be displayed. (Unit:°F / °C) Sensor type will be displayed under themeasurement; the factory default setting is Pt100.By using the software included with the Base Unit,you can change the sensor type.RTR-505-V (Voltage)Voltage measurement will be displayed. (Unit: V /mV) Due to the wide measurement range, the Unithas been set by default to adjust the decimal pointautomatically to display the measurement in V. Byusing the software included with the Base Unit, youcan change the unit of display.RTR-505-mA (4-20mA)4-20mA measurement will be displayed. (Unit: mA)OpticalCommunicationAreaModuleSensor JackAntennaLCD Display |
Related manuals for T&D RTR-505
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine