T&D RTR-574-S Manual
Also see for RTR-574: Introductory guideUser manualManual
Appearance Diagram and Part NamesTo prevent any loss or damage to our customers, other people and/or property, and to ensure theproper use of our products we ask that before using our product you carefully read, understand andfollow the safety rules and precautions for our products as outlined below.Explanation of Warning Symbols Explanation of Picture SymbolsDANGERThese entries are actions thatabsolutely under no circumstanceshould be taken. The taking ofsuch an action may cause seriouspersonal physical damage ordeath.Denotes an importantwarning or caution.Denotes a forbidden action.CAUTIONThese entries are actions that iftaken may lead to physical injuryor damage to persons or things.Denotes an action thatmust be taken.DANGERDo not take apart, repair or modify the Unit.Touching them may result in malfunction or unexpected accidents.If water or a foreign object enters into the Unit, immediately turn OFF the power, removebatteries, and stop using.Continued use may cause fire or electrocution.Do not use this Unit in wet or humid places, such as a bathroom.It may cause a fire or other trouble including malfunction.If water or a foreign object enters the case, immediately cease using it.Store the Unit and accessories out of the reach of children.Touching them may result in unexpected accidents.If any smoke or strange smells are emitted from the Unit, immediately turn OFF the power,remove batteries, and stop using.Continued use may cause fire or electrocution.Do not drop the Unit, or expose the Unit to a strong impact.If that happens to the Unit, immediately turn OFF the power, remove batteries, and stop using. Continued usemay cause fire or electrocution.When installing and using this product, make sure to follow all warnings and directions fromyour computer manufacturer.CAUTIONThis Unit is not waterproof.If the Unit gets dirty, wipe it with a clean cloth.Harmful gases or chemicals may cause corrosion and/or other danger to the Unit. Also, bycoming in contact with hazardous substances, harm may occur to the people handling theUnit. Therefore, do not use or store the Unit in any environment that is exposed tochemicals and harmful gases.Battery life varies depending upon the type of battery, the battery performance, themeasuring environment, and the frequency of communication.Battery terminals may provide insufficient contact due to age or vibration.This may lead to data loss.Use the Unit in an environment within the operational range.Condensation may occur when a Unit is moved from one environment to another wherethere is a great difference in temperature.To prevent damage to the Unit from static electricity, remove static electricity from yourbody by touching metal around you (door knob, window frame) before touching the Unit.Static electricity may cause not only damage to the Unit, but may cause breaks in or a loss of data.If the Unit is not to be used for a long period of time, for safety reasons please remove thebattery.If left in the Unit, it may leak and lead to malfunctioning.Please use a new battery when you use the Unitagain.Do not store or leave the Unit in any place exposed to high temperature and high humidity.If the Unit is not to be used for a long period of time, store it in a place with a normal temperature and withoutcondensation with other items included.Do not disconnect the communication cable during USB communication.This may harmfully effect the Unit or your PC.We shall not guarantee the operation of our device if you have connected it to yourcomputer using a USB hub or a USB extension cable.Please do not insert your fingers or any foreign objects into the sensor or USB connectionjacks.Do not use or store the Unit in any of the following places. Doing so may causeelectrocution, fire and/or other adverse effects to the device and/or your computer.-Areas exposed to direct sunlightThis will cause the inside of the Unit to become overheated and may cause fire, deformation, and/orother damage including malfunction.-Areas prone to strong magnetic fieldsThis may cause damage including malfunction.- Areas exposed to water leakageThis may cause electrocution or other damage including malfunction.- Areas exposed to excessive vibrationThis may cause injury, malfunction, damage or loss of proper electrical contact.- Areas near fire or exposed to excessive heatThis may cause damage including malfunction and deformation.-Areas prone to dust and dirtThis may cause damage including malfunction.Illuminance UV Recorder WL RTR-574 is a Data Logger, with built-in wireless communication capability, designed to measure and recordIlluminance, UV Intensity, Temperature and Humidity at a set interval.Recorded data can be downloaded from an RTR-574 Data Logger (Remote Unit) via wireless communication with a Base Unit; that data can then be viewed in a graph and/orsaved to PC for analysis or sharing over a network.As a Remote Unit, RTR-574 requires a Base Unit to carry out wireless communication. (Compatible Base Units: RTR-500, RTR-500NW, RTR-500AW,RTR-500DC, RTR-500MBS-A)The RTR-574 can be operated with "RTR-500 for Windows" version 1.10 or later.When you use "RTR-500 for Windows", please check the software version by selecting "Version Info" in the [Help] Menu. The latest version of thesoftware can be downloaded from our T&D Web Site.Before using an RTR-574, it is first necessary to install the USB Device Driver from the software that comes with the Base Unit.REC Mark The recording status is shown here.ON: Recording in progress.BLINKING: Waiting for programmed start.OFF: Recording has been stopped.DATA The number of recorded readings is shown in a scale here. After every2,000 readings the scale is marked from left to right. Storage capacity is8,000 readings.COM Mark The communication status is shown here.ON: The Unit is connected to a PC with the USB cable.BLINKING: The Unit is in Wireless/USB/Serial communication.Recording Mode ENDLESS:Upon reaching storage capacity of 8,000 readings, the oldest data isoverwritten and recording continues.ONETIME:Upon reaching storage capacity of 8,000 readings, recording willautomatically stop.Battery LifeWarning MarkWhen it is time for the battery to be replaced, this mark will appear.Not ON: Ample battery power.ON: Time to change the battery.Current Readings /Messages AreaNormally, the current readings are shown here. Depending on the Unit’sstatus, operational messages may also be displayed.Unit ofMeasurementHumidity: % , Temperature: ˚C / ˚F, Illuminance: lx, klxCumulative Illuminance: lxh, klxh, MlxhUV Intensity : mW/cm2 ,Cumulative Amount of UV Light: mW/cm2h, W/cm2 hAntennaSensor JackPOWER ButtonOperation Buttons(DISPLAY, INTERVAL,REC/STOP)USB CommunicationCable JackBattery CoverNotices about this ManualIn order to properly use this product, please carefully read this manual before using. T&D Corporation accepts no responsibility for any malfunction of and / or trouble with this product or with yourcomputer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty.- All rights of this Manual belong to T&D Corporation. It is prohibited to use, duplicate and / or arrange a part or whole of this Manual without the permission of T&D Corporation.- "TANDD", "T&D" and the logo of T&D Corporation are all registered property of T&D Corporation.- Specifications, design and other contents outlined in this manual are subject to change without notice.- We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our unit. Please be fully aware of this before using our product.- On screen messages in this manual may vary slightly from the actual messages.- Please notify the shop where you purchased this product or T&D Corporation of any mistakes, errors or unclear explanations in this manual.- T&D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product.- This product has been designed for private or industrial use only. It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment, whether directly or indirectly.- This Manual cannot be reissued, so please keep it in a safe place.- Please carefully read this Manual and Warranty.Safety Precautions and Instructions * Please carefully observe the following safety measures when using our product.18557860[Unit : mm]Cautions about using the Illuminance UV SensorsDo not connect the ISA-3151 sensor to any data logger other than those specified by T&DCorporation.Use the Unit in an environment within the operational range.When measuring UV light or other light which may cause damage or injury to your eyes orskin make sure to use protection such as safety glasses or some type of light-proof shield.Do not expose the sensor to a strong impact.Cracks or scratches in the Illuminance sensor and / or in the UV sensor will adversely affect the measurementaccuracy. Also, a broken sensor may result in injury.This sensor is not waterproof. By all means do not allow it to get wet.Do not expose to condensation, dampness, corrosive gases or organic solvents. Also, donot use in areas near fire or exposed to excessive heat.When the Illuminance UV sensor is not being used, please store at room temperature toprevent condensation.If the sensor surface gets dirty, wipe it with a soft cloth.If the sensor surface accumulates impurities (dirt), it will cause a decrease in the sensor’s accuracy andsensitivity.If you wish to extend the length of the sensor cable, please purchase and use our optionalsensor extension cable (TR-1C30 / TR-5C10).Do not cut or process the sensor cables.Using the "Adjustment Function" in the software supplied with the Base Unit, it is possible tomake desired adjustment settings to a sensor; these settings are saved directly into thesensor itself.Therefore, when a sensor is replaced, it is necessary to re-make any desiredadjustment settings to be saved into the newly connected sensor.Cautions about using the Temperature-Humidity SensorsDo not connect the THA-3001/3151 sensor to any data logger other than those specified byT&D Corporation.Use the Unit in an environment within the operational range.When using the THA-3001/3151 sensor in an environment where the humidity is less than30%RH, the measurements may sometimes fluctuate. This is not abnormal.If extremely severe temperature changes occur, the humidity measurements may appearabnormal.Once the sensor's temperature becomes stable, the measurements will return to normal.This sensor is not waterproof.Only use in an environment where there is no condensation or possibility of becoming wet. Do not use inwater or near areas where high-pressure water is flowing.Do not expose to condensation, dampness, corrosive gases, or organic solvents.When the sensor is not to be used for a long period of time, please store it at normaltemperature and humidity.During use, the surface of the temperature - humidity sensor will accumulate impurities (dirt) causing aecrease in the sensor’s accuracy and sensitivity. If the sensor is being used in an environment where smokeand dust are in abundance, periodic calibration may be required.Do not use this sensor on a human body.If you wish to extend the length of the sensor cable, please purchase and use our optionalsensor extension cable (TR-1C30 / TR-5C10).Do not cut or process the sensor cables.Using the "Adjustment Function" in the software supplied with the Base Unit, it is possibleto make desired adjustment settings to a sensor; these settings are saved directly into thesensor itself.Therefore, when a sensor is replaced, it is necessary to re-make any desiredadjustment settings to be saved into the newly connected sensor.Wireless RegulationsFCC StatementThis device complies with Part 15 of the Federal Communications Commission (FCC) rules. Operation is subject tothe following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept anyinterference received, including interference that may cause undesired operation.Caution:Changes or modifications not expressly approved by the party responsible for compliance could void the user'sauthority to operate the equipment.Note about Antenna Usage:This device has been designed to operate with the supplied antenna only. Use of any other antenna is strictly prohibited.IC Statement:This device complies with RSS-210 of the Industry Canada (IC). Operation is subject to the following two conditions: (1)This device may not cause harmful interference; and (2) This device must accept any interference received, includinginterference that may cause undesired operation.Ce dispositif est conforme à la norme RSS 210 d’Industrie Canada.L’utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et(2) l’utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage estsusceptible de compromettre le fonctionnement du dispositif.Important NoticeWireless products cannot be used in countries other than where those products have been approved for use, accordingto that country's wireless regulations.T&D Corporation shall in no manner whatsoever take responsibility for the usage of these products, nor be liable in anymanner for legal consequences stemming from the usage of these wireless products in unapproved areas.RTR-574 / RTR-574-SIntroductory ManualThank you for purchasing our product.Carefully read this instruction manual before using this Unit.RTR-574 Package ContentsIlluminance UVRecorder WLRTR-574Illuminance UVSensor(ISA-3151)Temperature- HumiditySensor(THA-3151)AA AlkalineBatteryUSBCommunicationCable (US-15C)IntroductoryManual(includingWarranty)RTR-574-S Package ContentsTemperature Humidity SensorIlluminance UVRecorder WLRTR-574Illuminance UVSensor(ISA-3151)Temperature- HumiditySensor(SHA-3151)AA AlkalineBatteryUSBCommunicationCable (US-15C)IntroductoryManual(includingWarranty)© Copyright T&D Corporation. All rights reserved. 2017.07 16504670035 (6th Edition)This is printed using recycled paper.Reading the LCD DisplayFrom hereafter in this manual, Illuminance UV Recorder WL RTR-574will be referred to as the "Unit". |
Related manuals for T&D RTR-574
manualsdatabase
Your AI-powered manual search engine