UEi EM152 Instruction Manual
EM152PHOLDZEROREC/MAXMIN/AVGSCALEpsiEM152PHOLDZEROREC/MAXMIN/AVGSCALEpsiINSTRUCTION MANUALENGLISHEM152Dual Differential Digital ManometerCopyright © 2016 UEi. All Rights Reserved.WARRANTYThe EM152 is warranted to be free from defects in materialsand workmanship for a period of one year from the dateof purchase. If within the warranty period your instrumentshould become inoperative from such defects, the unit willbe repaired or replaced at UEi’s option. This warranty coversnormal use and does not cover damage which occurs inshipment or failure which results from alteration, tampering,accident, misuse, abuse, neglect or improper maintenance.Batteries and consequential damage resulting from failedbatteries are not covered by warranty.Any implied warranties, including but not limited to impliedwarranties of merchantability and fitness for a particularpurpose, are limited to the express warranty. UEi shall notbe liable for loss of use of the instrument or other incidentalor consequential damages, expenses, or economic loss,or for any claim or claims for such damage, expenses oreconomic loss.A purchase receipt or other proof of original purchase datewill be required before warranty repairs will be rendered.Instruments out of warranty will be repaired (whenrepairable) for a service charge.17240 • 1015A. Pressure Sensor Inputs:• Left Connection: Negative pressure port.• Right Connection: Positive pressure port.B. Display: with Backlight.1. Hold: Values are captured/held.2. Dif: Pressure Differential.3. Record: The manometer will record the MaximumPressure, Minimum Pressure and Average Pressure.4. MAX/MIN/AVG:- MAX: Maximum value captured is displayed.- MIN: Minimum value captured is displayed.- AVG: Timed mean value calculation displayed.NOTE: REC/MAX/MIN/AVG function does not workwhen in ∆P/Pressure Differential test mode.5. Battery: When battery is too low for safe operation,the Low Battery indicator will display (BAT). SeeBattery Replacement section of this manual.6. Time (H/M/S): Hours/Minutes/Seconds.C. Power Button (Green): Press to turn on manometer.Press to turn off manometer.D. ∆P/Pressure Differential Button: Used to start and stoppressure differential test.E. REC/MAX/MIN/AVG Button: Press to record Max/Min/Avg values.F. HOLD/ZERO Button: Press to capture displayed value orzero meter.• Auto power off after 25 minutes of inactivity.• To disable Auto power off: with the meter off, press thePOWER button, then press and hold the HOLD/ZERObutton until a ‘n’ displays.G. Backlight Button: Press to turn on Backlight. Press againto turn off.• Provides easy reading of Display in dark work environments.• Backlight duration is 50 seconds.H. Scale Button: 11 Selectable Units of measurement.I. Magnetic Mount: For hands-free work.J. Battery Cover: Easy access for replacing batteries.OVERVIEWACEDFGH JIBSPECIFICATIONSFunction Ranges Resolution Accuracy (77˚F)Bar ± 0.200 0.001± 0.3% FullScale OuputOunces/Sq. Inch ± 46.60 0.01PSI ± 2.900 0.001inHg ± 5.904 0.001mBar ± 200.0 0.1mmHg ± 150.0 0.1kPa ± 20.00 0.01Kg/Sq. cm ± 0.204 0.001In H2O ± 80.27 0.01Ft H2O ± 6.689 0.001cm H2O ± 203.9 0.1FEATURES• Range of -60 to +60 inH2O• Differential Pressure• Dual input differential measurement to ±80.27 inches of .water column• Measures in 11 scales; inH2O, PSI, Bar, mBar, kPa, inHG, .mmHG, ozin, FtH2O, cmH2O and kgcm.• Magnetic Mount• Auto Ranging• Backlit Display• Data Hold• Max/Mn• Zero ButtonGENERAL SPECIFICATIONS• Operating Temperature: 32˚ to 104˚F (0˚ to 40˚C)• Storage Temperature: 14˚ to 140˚F (-1˚ to 60˚C)• Backlight: Display Backlight• Over-range: ERR1 or ERR2 is displayed• Dimensions: 5.27" X 3" X 1.5"• Item Weight: 6.2 oz.• Calibration: Calibration• Battery Type: 9V X 1IMPORTANT SAFETY WARNINGSWARNING• Read entire Safety Notes section regarding potential hazardsand proper instructions before using this manometer. In thismanual the word “WARNING” is used to indicate conditionsor actions that may pose physical hazards to the user. Theword “CAUTION” is used to indicate conditions or actionsthat may damage this instrument.• To avoid false readings, replace batteries if a low batteryindicator appears.WARNING• WARNING Do not exceed Maximum Over Pressure of 10 psi.• Do not use the manometer if it operates abnormally.• Always test the manometer before use to ensure it isoperating properly.• Always ensure that the connecting hoses you are using arefree from kinks, blockage or splits.• Always double-check all connections before testing.• While using the manometer, if you suspect gas is leaking, orif you can smell gas, close off gas supply and ventilate theoccupied space. Identify and repair the source of the leakbefore continuing with the test.• Never connect the manometer to an unknown pressuresource if the source is twice the working pressure of theinstrument; the sensor may be damaged and it maycause injury to the user.• Never open the manometer or attempt to modify it in anyway. Otherwise, accident and injury may occur. And thewarranty is voided.• These manometers do not measure water pressures; underthese conditions they will fail.WARNING• This manometer is designed for trained trade professionalswho are familiar with the hazards of their trade. Observe allrecommended safety procedures and use of personalprotective equipment.SYMBOLSHold/Capture ValueMaximum measured value displayedMinimum measured value displayedWarning or CautionNegative Pressurewww. .com information@itm.com1.800.561.8187 |
Related manuals for UEi EM152
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine