Vapotherm Precision Flow Quick Reference Manual
Also see for precision flow: Operating instructions manualInstructions for useInstructions for use
• Attach High or Low Flow Vapor Transfer Cartridge to Disposable Water Path• Attach patient delivery tube to Disposable Water Path• Open door and install Disposable Water Path into docking station• Hang sterile water bag• Wipe water spike with alcohol pad and insert into sterile water bag• Allow a minimum of 200ml of water to fill into the Disposable Patient Circuit• Precision Flow is ready for start up• Press the Run/Standby button. Unit will enter Standby mode.• Clamp the water inlet tube and disconnect it by pulling out the spike.• Open the door, remove the Disposable Patient Circuit (includes deliverytube & cartridge) by sliding it upwards out of the docking station• Discard all disposables according to hospital guidelines.• Disconnect unit from AC power.Q U I C K R E F E R E N C E G U I D EVAPOTHERM, INC.22 Industrial DriveExeter, NH 03833T: 603-658-0011USA3006001 Rev. DThis guide provides you with basic instructions on how to set up and operate thePrecision Flow.™ Before operating the Vapotherm Precision Flow,™ please review theOperators Instruction Manual which can be found at our website www.vtherm.comBlocked tubeGeneral faultWater outAlarm muteLEDAlarm mutebuttonSetting ControlKnobBattery low orcharging (notindicative of charge)level)DisposableWater Pathfaulty or absentLow Flow VaporTransfer CartridgeHigh FlowVapor TransferCartridgeVapor TransferCartridge fault (Lowflow & High flow)Gas supply faultRun/StopStatus LEDRun/StandbybuttonQ U I C K R E F E R E N C E G U I D ETechnical SupportT: +1 (603) 658-5121 International855 557 8276 Domesticts@vtherm.com• Install oxygen sensor• Install gas inlet filters on back with filter bowls vertical (glass side down).• Attach air & O₂ hoses. Plug in power cord.• Rotate the blue Setting Control Knob to illuminate display• Press in Setting Control Knob to select the parameter and rotate to adjustthe value• Press and release (do not hold) the Run/Standby button once to start.A GREEN light indicates RUN mode (AMBER light indicates STANDBY mode,No Flow)• Green light will stop flashing once temperature is reached• The flashing green LED becomes steady when the set variables are reached.• Place the cannula on the delivery tube• After cannula is attached, it is ready to be placed on patient• To activate the internal backup battery mode, the Run/Standby LED mustbe green before disconnecting the power cord.• The unit will enter into battery mode and will maintain flow and oxygenpercentage for at least 15 minutes.• The battery icon will flash.DISPOSABLE PATIENT CIRCUITSTART UP AND ADJUSTING PARAMETERSCONNECT TO PATIENTBATTERY BACK-UP MODESHUT DOWN MODEMay be patented. www.vtherm.com/patents |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine