Watt Stopper WRC-15 Series Instructions Manual
WRC-15-x, WRC-20-x with WRC-TXRadio Frequency (RF) Plug Load ControllerCommande de charge de prise à fréquence radio (RF)Controlador para cargas comunes con alimentación CAde radiofrecuencia (RF)Installation Instructions • Instructions d’Installation • Instrucciones de InstalaciónDESCRIPTIONThe Radio Frequency (RF) Plug Load Controller expands the energy savings obtained fromtraditional occupancy sensing to encompass AC receptacles as well as built-in lighting. Weaccomplish this by providing an RF transmitter (WRC-TX) that connects to your new or existingoccupancy sensor, and a switched AC receptacle (WRC-15-x, WRC-20-x) that contains a built-inRF receiver. When the RF Signal Pack (transmitter) receives an “vacancy” signal from thesensor, it transmits a message commanding the receptacle to turn off. Similarly when theoffice becomes occupied, the sensor sends a signal to the RF transmitter and the receptaclesturn on. This RF Signal Pack connects to any WattStopper occupancy system which uses aBZ series Power Pack. Each RF Signal Pack can control up to 16 RF receptacles. A switchedfeed through allows for control of downstream receptacles from a single RF receptacle.Recommended communication range between RF Signal Pack and RF Receptacle is 30 feet.Greater distances can be achieved in ideal environments.RECEPTACLE INSTALLATION INSTRUCTIONS1. After removing power as described above, use strip gage on back of outlet to stripall wires to desired length (if not already stripped).2. Attach wires according to the diagram below. Be sure the wires are fastenedsecurely either by the terminal screws or through the back-wire holes in the backof the outlet.Figure 1WARNING: LOOSELY FASTENED WIRES MAY RESULT IN OUTLET FAILURE AND/ORFIRE HAZARD.If using terminal screws: Terminal screws accept up to #12 AWG wire. Wrap eachstripped wire 3/4 turn clockwise under heads of screws without overlapping andtighten securely.If using back-wire method: Back-wire accepts up to a #12 AWG wire. Insert strippedwire between external pressure plate clamp and terminal. Tighten securely.3. Mount outlet in box using mounting screws supplied. Attach wall plate. Restorepower only when finished wiring the entire circuit.RF SIGNAL PACK INSTALLATION INSTRUCTIONSAcoustic Tile MountingInstall the Threaded Insert, flange side,into the hole on the back of the sensorand turn clockwise until it locks.Keyhole Mounting1. Use the template below to markthe location of mounting screws.2. Install the provided screws –leaving approximately 3mm (1/8”)space from the bottom of thescrew head to the ceiling (seeFigures 2A and 2B).3. Place the RF Signal Pack’smounting keyholes over screwheads and rotate sensorclockwise until secured.WIRING DIRECTIONSWARNINGTurn power off at the circuit breakerbefore working with or near high voltage.Wire the RF Signal Pack to the occupancy sensor and BZ series Power Pack according tothe diagram below (Figure 3).Sensor wiring:• BLUE wire from power pack to BLUE wire from sensor. Blue (CONTROL)• RED wire from power pack to RED wire from sensor. Red (24V)• BLACK wire from power pack to BLACK wire from sensor. Black (0V)Figure 3Procedure for Binding1. Press and hold BIND button on RF Signal Pack for 5 seconds until multi-colored LEDon RF Signal Pack flashes amber. All RF receptacles that are not already bound to anRF Signal Pack will now flash green noting ready to bind. Any RF receptacle alreadybound to this RF Signal Pack will flash amber. Any RF receptacle out of range or boundto another RF Signal Pack will not change state. If your RF receptacle is not flashing,reset to factory default state by holding the receptacle BIND button for approximately15 seconds until the LED is a solid amber.2. Press and hold BIND button on RF Receptacle for 2 seconds until LED onreceptacle flashes amber noting it is properly bound. If it was previously boundto this RF Signal Pack (was flashing amber prior to holding BIND button for 2seconds) it will unbind and flash green.3. Repeat for all RF receptacles in room network.4. Return to original RF Signal Pack and press and hold BIND button for 5 secondsuntil flashing LED on RF Signal Pack turns off. All RF receptacles on the sameroom network will stop flashing indicating Binding is complete.5. Test that binding has been successful by tapping the push button of the RF SignalPack and confirm that the green led on the receptacles turn on and off.Operating InstructionsThe green LED on the receptacle is on when the outlet has power, and off when the outletis switched off. The bind button on the receptacle or the RF Signal Pack can be pressed tooverride the occupancy sensor and turn on the receptacle temporarily.This equipment complies with part 15 of the FCC Rules which are designed to providereasonable protection against harmful interference in a residential installation. Thisequipment generates, uses, and can radiate radio frequency energy and, if not installedand used in accordance with the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference will not occur in aparticular installation. If this equipment does cause harmful interference to radio ortelevision reception, which can be determined by turning the equipment off and on, the useris encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which thereceiver is connected.• Consult the dealer or an experienced radio/TV technician for help.15A or/ou/o 20AControlled / Contrôlé /ControladoGreen or Bare Wire / Fil vert ou nu / Cable verde o peladoNeutral / Neutre / Neutro15A or/ou/o 20AHot / Sous tension / VivoWhite ScrewVis blancheTornillo blancoGreen ScrewVis verteTornillo verdeGreen ScrewVis verteTornillo verde125V125V250VWhite ScrewVis blancheTornillo blancoNot required if bothfaces are controlledN’est pas nécessaire si lesdeux faces sont contrôléesNo es necesario si secontrolan ambas carasBrass ScrewVis en laitonTornillo de latónor/ou/oCONTROLLEDCONTROLLEDBrass ScrewVis en laitonTornillo de latónBrass ScrewVis en laitonTornillo delatónCONTROLLEDCONTROLLEDNut/Écrou/TuercaWasher/Rondelle/ArandelaThreaded InsertInsert filetéAccesorio roscado7/8" (22mm) hole/Orifice de 22 mmOrificio de 22 mm (7/8")Ceiling TileDalle de plafondPlaca de techoRotate clockwise/Tournez dans le sens des aiguilles d’une montreGirar hacia la derechaCeilingPlafondCielo rasoSpace: 3mm (1/8")Espace : 3 mmEspacio: 3 mm (1/8")Screws: 70mm (2.75") apartVis : Écart de 70 mmTornillos: Separación de 70 mm (2,75")Figure 2BControl Output 24VDC (BLU)Sortie de régulation 24 VCC (BLEU)Salida de control de 24 V CC (AZUL)+24VDC (RED)+24 VCC (ROUGE)+24 V CC (ROJO)LightingLoadCharged’éclairageCarga deiluminaciónWhite (NEUTRAL) / Blanc (NEUTRE) / Blanco (NEUTRO)10 Sensors PerBZ Power Pack Max10 détecteurs maximum parbloc d’alimentation BZ10 sensores máximo porpaquete de alimentación BZRed (LOAD)Rouge (CHARGE)Rojo (CARGA)Red (LINE)Rouge (SECTEUR)Rojo (LÍNEA)WhiteBlancBlancoBlackNoirNegroHotSous tensionVivoN POWER PACKBLOCD’ALIMENTATIONPAQUETE DEALIMENTACIÓNOptional Switch to ControlLighting Load OnlyCommutateur optionnel pour contrôlerla charge d’éclairage uniquementInterruptor opcional para controlarla carga de iluminación únicamenteControl Input 24VDC (BLU)Entrée de régulation 24 VCC (BLEU)Entrada de control de 24 V CC (AZUL)Common (BLK)Commun (NOIR)Común (NEGRO)+24VDC (RED)+24 VCC (ROUGE)+24 V CC (ROJO)Common (BLK)Commun (NOIR)Común (NEGRO)16 ReceptaclesPer RF Signal Pack Max16 prises maximum parbloc de signal RF16 receptáculos máximopor paquete deseñales RFRFRFRF16 ReceptaclesPer RF SignalPack Max16 prises maximumpar bloc designal RF16 receptáculosmáximo porpaquete deseñales RFREAD & SAVE THESE INSTRUCTIONS! CAUTION:• To prevent severe shock or electrocution, always turnpower OFF at the service panel before working with wiring.• Use this device with copper or copper-clad wire. Do not usewith aluminum wire.• Class 2 devices to be connected to Class 2 power source only.• Must be installed in accordance with National and Localelectrical codes.WARNING: IMPROPER WIRING OF ANY ELECTRICAL DEVICECAN CAUSE SERIOUS INJURY OR DEATH. THESE WIRINGDEVICES SHOULD BE INSTALLED BY AN ELECTRICIAN OR OTHERQUALIFIED PERSON.LIRE ET CONSERVER CES INSTRUCTIONS. ATTENTION• Pour éviter tout choc électrique ou une électrocution, coupeztoujours l’électricité au niveau du panneau d’alimentationavant de commencer à câbler.• Utilisez ce dispositif avec des fils en cuivre ou cuivrés. Nel’utilisez pas avec des fils en aluminium.• Les composantes de classe 2 doivent être raccordés à unesource d’ alimentation de classe 2 seulement.• Doit être installé conformément aux codes locaux etnationaux de l’électricité.AVERTISSEMENT: LE CÂBLAGE INCORRECT DE TOUT DISPOSITIFÉLECTRIQUE PEUT CAUSER DES BLESSURES GRAVES, VOIRE LAMORT. CES DISPOSITIFS DE CÂBLAGE DOIVENT ÉTRE INSTALLÉSPAR UN ÉLECTRICIEN OU UNE PERSONNE QUALIFIÉE.LEA Y GUARDE ESTAS INSTRUCCIONES. PRECAUCIÓN:• Para evitar serios electrochoques o electrocución, siempreAPAGUE el suministro eléctrico en el panel de servicioantes de trabajar con los cables.• Utilice este dispositivo con alambres de cobreo revestidos de cobre. No usar con cables de aluminio.• Dispositivos Clase 2, sólo deben conectarse a fuentes dealimentacion Clase 2• Se debe instalar de acuerdo con los códigos eléctricosnacionales y locales.ADVERTENCIA: EL CABLEADO INCORRECTODE UN DISPOSITIVO ELÉCTRICO PUEDE CAUSAR LESIONESGRAVES O AÚN LA MUERTE. UN ELECTRICISTA U OTRA PERSONACOMPETENTE DEBE INSTALAR ESTOS DISPOSITIVOS DE CABLEADO.INSTRUCTIONS EN FRANÇAISDESCRIPTIONLa commande de charge de prise à fréquence radio (RF) accroît les économies d’énergieobtenues grâce aux méthodes de détection de présence traditionnelles en incorporantdans le système les prises CA ainsi que l’éclairage intégré. Ceci est effectué au moyen d’unémetteur RF (WRC-TX) qui se branche à votre détecteur de présence (existant ou nouveau),et une prise CA commutée (WRC-15-x, WRC-20-x), munie d’un récepteur RF intégré. Lorsquele bloc de signal RF (l’émetteur) reçoit du détecteur un signal « d’absence d’occupation », iltransmet un message de commande pour mettre la prise hors tension. De même, lorsque lebureau est à nouveau occupé, le détecteur envoie un signal à l’émetteur RF et les prises sontmises sous tension. Ce bloc de signal RF se branche à n’importe quel système de détectionde présence WattStopper qui utilise un bloc d’alimentation BZ. Chaque bloc de signal RFpeut contrôler jusqu’à 16 prises RF. Une alimentation commutée permet le contrôle par uneseule prise RF des prises situées en aval. La portée de communication recommandée entrele bloc de signal RF et la prise RF est de 9 m. Des portées plus importantes sont possiblesdans des conditions d’utilisation idéales.INSTRUCTIONS DE MONTAGE DE LA PRISE1. Après avoir coupé l’alimentation tel qu’indiqué ci-dessus, utilisez le gabarit dedénudement situé au dos de la prise pour dénuder tous les fils à la longueur souhaitée(si ce n’est pas déjà fait).2. Raccordez les fils comme indiqué dans la figure 1. Serrez correctement les fils au moyendes bornes-vis ou dans les orifices arrière de fixation des fils au dos de la prise.70 mm (2.75")PLACE TEMPLATE on ceilingPOSITIONNEZ LE GABARIT au plafondCOLOCAR PLANTILLA en techo1Pierce and Mark both CENTER POINTS for Mounting ScrewsMarquez et percez les deux POINTS CENTRAUX pour les vis de montagePerfore y marque ambos PUNTOS CENTRALES para tornillos de montaje2Figure 2A |
Related manuals for Watt Stopper WRC-15 Series
Watt Stopper MRDS10 Installation Instructions Manual
Watt Stopper LMRC-222 Installation Instructions Manual
Watt Stopper DRD6 v2 Installation Instructions Manual
Watt Stopper DRD8 v2 Installation Instructions Manual
Watt Stopper LightSaver LS-100XA Installation Instructions Manual
Watt Stopper LS-101 Quick Start Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine