GENERALBelow are descriptions of option packages available on theSunline Plus (3 and 7.5 through 20 ton) and Sunline Ultra (3,4and 5 ton) units. There are 4 option packages, the: BASE OP-TION PACKAGE, PROTECTION PACKAGE, INSTALLATIONPACKAGE, and CABINET PACKAGE. The BASE OPTIONPACKAGE can be ordered alone, but is always included withany of the other option packages.FACTORY OPTIONSThe following factory options can be ordered in conjunctionwith any of the OPTION PACKAGES:A. No Economizer.B. Dry Bulb Economizer.C. Dry Bulb Economizer with Power Exhaust (15 & 20 ton units only).NOTE: Not all combinations of base units and option packagesare available. See the Price Pages for specific modeland option combinations.All option packages are available with the dry bulbeconomizer option only.Individual items within each package can not bebroken-out and ordered separately.BASE OPTION PACKAGEA. High-speed drive (15 & 20 ton units) includes a belt andblower pulley upgrade, an alternate hp motor (7 - 12 tons)or the belt drive option (3 - 5 tons).B. Self-priming condensate cover assists in priming a dry trap.C. A sloped drain pan to prevent standing water in the drainpan.NOTE: The internal drain connection is not offered with thesloped drain pan design on the 15 & 20 ton units.D. Smoke detector terminal block provisions provide field-wiring means for powering a 24VAC duct smoke detectorand a single set of normally closed contacts, which open toshut down the unit upon detection of smoke. Although theair conditioning unit is shut down when the smoke detectoralarms, the 24V power supply to the smoke detector is notinterrupted. Actual mounting means for the smoke detectorare not provided due to the wide variation in regulationsand codes.CAUTION: Normal maintenance activity will require discon-necting power to the unit. When the YORK sup-plied terminal strip is used to provide 24V power toa smoke detector; the smoke detector will not bepowered when the power supply is interrupted tothe unit. If the smoke detector is linked to separatemonitoring system that would detect this powershutdown and report it as an alarm condition, donot use the unit terminal strip to power the smokedetector.24VACPOWERSUPPLY5VA(Max.)NORMALYCLOSEDCONTACTS24VACUNITWIRINGUNITWIRINGTERMINALBLOCKS(locatedinEconomizersection)FieldSuppliedWiringWiredto24VACpowerterminalsofsmokedetectorJUMPERRemovejumperandwiretothenormallyclosedcontactsofthesmokedetectorSMOKE DETECTOR TERMINAL BLOCK DIAGRAM® OPTION PACKAGESINSTALLATION INSTRUCTION Supersedes: 530.24-N1Y (199) 035-16134-000 Rev. A (0501)FOR SUNLINE™MODELS DHE, DHG 036, 048 & 060, 180 & 240MODELS DEE, DEG 036