York YOCA-YOHA 12-60 Installation & Owner's Manual
INSTALLATION &OWNER’S MANUALMINISPLIT FLOOR/CEILINGAIR CONDITIONERMODELS : YOCA-YOHA 12-60REQUIRED TOOLS1. Screw Driver 9. Manifold Guage2. Hexagonal Wrench 10. Gas Leak Detector3. Torque Wrench 11. Vacuum Pump4. Spanner 12. Pipe Clamp5. Reamer 13. Pipe Cutter6. Hole Core Drill 14. Flare Tool Set7. Tape Measure 15. Electrical Circuit Tester8. ThermometerEXTENDED PARTS1. Refrigerant Pipe : See Technical Specification2. Pipe Insulation Material (Polyethylene foam 9 mm thick)3. Vinyl Tape4. Putty• Please read this installation manual carefully before starting installationof the unit.• This air conditioning system contains refrigerant under pressure, rotatingparts and electrical connection which may be dangerous and can causeinjury. Installation and maintenance of this air conditioning system shouldonly be carried out by trained and qualified personnel.• After unpacking, please check the unit carefully for possible damage.• Before undertaking any work on the unit, make sure that the power supplyhas been disconnected.CAUTIONS FOR INSTALLATION• Do not store or unpack the unitin a wet area or expose to rainor water.It may cause the unit to short circuit and mayresult electric shocks or fire.• Do not install in a place whereflammable gas may leak.It may cause fire.• Do not conduct installation in wetarea or in the rain.It is a high risk to cause the electrical shocks.• This system is designed fordomestic or residential use only.If used in certain environments, such as amanufacturing workplace, the equipment maynot function efficiently.PART LISTINDOOR UNITYOCA-YOHAINSTALLATION ACCESSORIESE N G L I S HEN Ceiling & Floor TypePREPARATION BEFORE INSTALLATION• Before doing any work, check the interior power supply cord and the mainbreaker capacity are sufficient and the installation area is sufficient andcomplies with the requirements.• Check that the power supply available agrees with nameplate voltage.• Electrical work, wiring and cables must be performed in compliance withnational and local wiring codes and standard.• Do not use the extension cables. In the case extended cables are needed,use the terminal block.SELECTION OF THE LOCATIONINDOOR UNITOUTDOOR UNITINSTALLATIONINSTALLATION SITETo install the air conditioner in the following types of environments,consult the shop.• Places with an oily ambient or where steam or soot occurs.• Salty or corrosive environments such as coastal areas.• Places where sulfide gas occurs such as hot springs.The drain from the outdoor unit must be discharged to a place of good drainage.CONSIDER NUISANCE TO YOUR NEIGHBOURSFROM NOISESFor installation choose a place as described below.• A place solid enough to bear the weight of the unit and which does notamplify the operation noise or vibration.• A place from where the air discharged fromthe outdoor unit or the operation noisewill not annoy your neighbours.ELECTRICAL WORK• For power supply, be sure to use a separate power circuit dedicated to the airconditioner.SYSTEM RELOCATION• Relocating the air conditioner requires specialized knowledge and skills.Please consult the shop where you bought the air conditioner if relocation isnecessary for moving or remodelling.SAFETY PRECAUTIONSSelect a place which provides the space around the units as shown inthe diagram below.To preventinterference,place at least1m away. Inverter-typefluorescentlamp. TVA place withgoodventilation.AirOutlet AirInletRadio035M00173-003Dimension(mm)YOCA-YOHA12 18 24 36 48 60A 2300 2300 2300 2300 2300 2300B 2300 2300 2300 2300 2300 2300C 5 5 5 5 5 5D 120 120 120 120 120 120Dimension(mm)YOCA-YOHA12 18 24 36 48 60A 300 300 300 300 300 300B 2000 2000 2000 2000 2000 2000C 600 600 600 600 600 600D 300 300 300 300 300 300Description Qty USEHook2For wall mounting installationHanging arm2For ceiling installationTapping Screw (ST2.9x10-C-H)2Remote Controller1FrameAlkalina dry batteries (AM4)1Install & Owner’s manual and User’sguideInstallation &Owner's ma nualUser' s Guid e2NAMES AND FUNCTIONSNOTICE!The chart based on one model of our product is for reference only, which may bedifferent from the unit you purchased.a indoor unit b outdoor unitc remote controller d air-ine air flow louver (at air outlet) f connecting pipeg drain hose h air inlet (with air filter in it)i installation part j DEF./ FAN indicator (For cooling andheating type, it’s DEF., for cooling onlytype, it’s FAN)k infrared signal receiver l operation lampm timer indicator n alarm indicatoro temporary button p air-outfcgnmolkJia edhpbdpOPERATIONTIMERDEF./FANALARMMANUALWALL MOUNTING INSTALLATIOND. Connecting pointof refrigerant pipe(D. gas side)Drain pointE. Connecting pointof refrigerant pipe(E. Liquid side)HookChart 51. Fix the hook with tapping screw onto the wall.(Refer to Chart 6)2. Hang the indoor unit on the hook.<6mmHookChart 6Tapping screwWasherDisplay PanelJ422_EN.indd 1 10/30/07 11:00:45 AM |
Related manuals for York YOCA 12
York YOCC-YOHC 12-60 Installation & Owner's Manual
York YKCA 18 Installation & Owner's Manual
York HMCA 18-27 Installation & Owner's Manual
York RLCA-RLHA Installation And Owner's Manual
York YUKC 07-18 Installation & Owner's Manual
York HVHC 07-12DS Installation & Owner's Manual
York RVHC 09-12DS Installation & Owner's Manual
York MLCA-MLHA-07-24 Installation & Owner's Manual
York MBC-MBH 25 Installation & Owner's Manual
York RMHC 18-30 Installation & Owner's Manual
manualsdatabase
Your AI-powered manual search engine