Zamel exta ZCM-22 Series Instruction Manual
*apply to the product ZCM-22P/UZCM-22, ZCM-22P/U TIME PROGRAMMERANNUAL, SINGLE-CHANEL INSTRUCTION MANUALZAMEL sp. z o.o.ul. Zielona 27, 43-200 Pszczyna, Polandtel. +48 (32) 210 46 65, fax +48 (32) 210 80 04www.zamel.com, e-mail: export@zamel.pl*apply to the product ZCM-22P/UCONNECTION*PRODUCT FAMILYZCM-22 Programmer belongs to ZCMfamily of products.MOUNTING, OPERATION1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch- disconnector combined to the propercircuit.2. Check if there is no voltage on connection cables by means of a special measure equipment.3. Install the ZCM-22 on the TH 35 DIN rail in the switchboard.4. Connect the cables with the terminals in accordance with the installing diagram.5. Switch on the power supply from the mains.The contact will be ON at 00:00:00. The contact will be OFF the previously set day during an hour changing from23:59:59 into 00:00:00 (the next day). If the contact is to be ON only one day, the same data should be set for ON andOFF date, e.g. ON - 02.02, OFF - 02.02. The lower program no. the higher program priority. The ON state has higherpriority than the OFF state within the given program.INNER DIAGRAMRELAY CAPACITYDIMENSIONSEXTERNAL MEMORY OPERATION*External memory allows for an easy record / reading of the adjusted programs intothe external memory, so they can be easily copied to other programmers. It is veryconvenient in case if we want to program more ZCM programmers or archive theadjusted programs.– sub menu to the external memory operation– programs recording– programs reading from the external memory and storage in the program-mer’s memory– the state of memory „busy” during a record / reading– correct record / reading– record /reading errorAPPEARANCE*FEATURESTECHNICAL DATADESCRIPTIONZCM-22, ZCM-22P/UPower supply clamps: A1, A2Rated voltage: ZCM-22: 230 V AC~(-15 ÷ +10 %)ZCM-22P/U: 24 ÷ 250 V AC, 30 ÷ 300 V DCRated frequency: 50 / 60 HzRated power consumption: ZCM-22: 1,6 W /17 VA ZCM-22 P/U: 1,5 W /3 VANumber of channels: 1Program quantity: 400 (200 On/Off pairs)Programme: weekly - annualMode of work: manual, automaticChange of season summer/ winter: automatic, manualColour of LCD panel lighting: amberInput: yesAccuracy of time measurement: max. ±1 s / 24 h at temp. 25 °CTime of clock maintenance: 3 yearsTime of programme maintenance: 10 yearsClamps of release system: IN, IN, IN, INClamps of receiver power supply: 11, 12, 14Parameters of transmitter contacts: 1NO/NC-16 A/250 V AC1 4000 VANumber of terminating clamps: 12Intersection of terminating conductors: 0,2 ÷ 2,50 mm2Temperature of work: -20 ÷ +60 o CPosition of work: anyFixing of casing: TH 35 rail (PN-EN 60715)Level of protection of casing: IP20 (PN-EN 60529)Protectivity class: IIOvervoltage category: IILevel of pollution: 2Measurements: two-module (35 mm) 90x35x66 mmWeight: 0,14 kgCompatibility with norms: PN-EN 60730-1; PN-EN 60730-2-7;PN-EN 61000-4-2,3,4,5,6,11● Control depending on current date,hour and minute,● double-module casing with a protec-tion flap,● additional control input IN,● many programmes enabling variousapplications,● LCD display illumination,● mounted on TH 35 rail,● a possibility to copy and read pro-grams from the external memory*.Digital control time switch ZCM-22 is usedto realise the time functions in automationand control systems. The programmer re-alises the output relay control operationsaccording to program adjustments (day,month, hour, minute). All systems areequipped with a control input function,which is used to change the operatingmode of a system by means of an exter-nal push-button. The design of the cas-ing allows the system to be mounted on aTH-35 rail and eventually to seal the de-vice. The design of the system providesa battery back-up system for all adjust-ments in case of no voltage supply.In order to protect the battery duringstorage, the ZCM series programmershave a default setting, the so-calledstorage mode in which the batterypower consumption is limited to a mini-mum.The device should be connectedto a singlephase system ac-cording to current standards.The device connections will bedescribed in this manual. Onlyqualified electricians are allowedto mount, connect and adjust thedevice. It is necessary to readthis manual and know the unit functions before thedevice mounting. Do not disassembly the devicecasing or you will lose any warranty rights and ex-pose yourself to the electric shock hazard. Beforemounting operation make sure of disconnectingthe connection wires from the electric network.Use a cross-head screwdriver of 3.5 mm diameterto mount the device. The relay should be carried,stored and used in an appropriate way. Do notmount the device in case of any device parts lack,damage or deformation. In case of malfunctionplease notify the manufacturer.CAUTIONplik: zcm-22_pu_bateria_inst_ext_gb | modyfikacja: 28.10.2019WARRANTY CARDThere is 24 months guarantee on the productSalesman stamp and signature, date of sale1. ZAMEL provides a two-year warranty for its products.2. The ZAMEL warranty does not cover:a) mechanical defects resulting from transport, loading / unloading or other circumstancesb) defects resulting from incorrect installation or operation of ZAMEL products;c) defects resulting from any changes made by CUSTOMERS or third parties, to products sold or equipment necessary for the correctoperation of products sold;d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable;e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear);3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.;4. ZAMEL will review complaints in accordance with existing regulations.;5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy be-tween the goods and the contract.Programmer type:11 - week (1 channel)12 - week (2 channel)31 - astronomicalDevice typePower supply:ZCM-xx - 230 V ACZCM-xx/U - 24 ÷ 250 VAC30 ÷ 300 V DC22 - weekly - year Winter timeSummer timeManual modeAutomatic modeWeek’s dayRelay stateInfo fieldCurrent time(gg:mm:ss)Power terminals(A1, A2)LCD displayExternal memory*Replaceable batteryControl buttonsRelay output terminals(12, 12, 11, 11, 14, 14)Trigger terminals(IN, IN, IN, IN)L(+)L(+) / N(-)N(-)Do not dispose of this device with otherwaste! In order to avoid harmful effectson the environment and human health,the used device should be stored indesignated areas. For this purpose, youcan dispose of household waste free ofcharge and in any quantity to a collectionpoint set up, as well as to the shop whenyou buy new equipment. |
Related manuals for Zamel exta ZCM-22 Series
Zamel exta RTM-20 Instruction Manual
Zamel exta SRM-11 Instruction Manual
Zamel exta SRP-01/M Manual Instruction
Zamel exta MOM-02 Instruction Manual
Zamel exta ZIM-12/25 Instruction Manual
Zamel exta free RZB-01 Manual Instruction
Zamel exta life ROB-21 Instructions Manual
Zamel SRP-03 Manual Instruction
Zamel Exta Free EFC-02 Mini Manual Instruction
Zamel exita ZIM-12/08 Instruction Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine