Zksoftware C3-100 Installation Instructions And Connection Manual
Key holeThread holeThread hole3.Get through the thread holeGet through the thread hole Fixed case1 24.LED indicators, Wires, Auxiliary Input and OutputAppearance of caseNotes:C3-100 Installation Instructions and Connection Guide1.CautionsPlease note the following cautions.Mis-operation may lead to personal injury or equipment failure:1) Do not energize the system before installation is complete; never carry out installation activities whenVision:1.0.1 Date:Oct. 20102) All peripheral devices must be grounded.3) It is preferred that all wires run through PVC or galvanized pipes.5) It is recommended that card readers and buttons should be installed at height of 1.4m-1.5m above ground.6) It is recommended to use the power supply in case for control panel, and external power supply for each4) It is strongly recommended that the length of exposed part of any connection cable should not be longerProfessional clamping tools may be used to avoid unintentional contact of exposed wires tothan 4 mm.the system is energized.short-circuit or communication failure.avoidDescription of normal working state:Connect the system to the power supply.If the system works properly,the POWER indicator(red) is litconstantly and the RUN indicator(green) flashes.Heatdissipationhole2.ComponentsPower supplyBackup battery Control panel1)Meaning of LED indicators:LINK indicator(green): always(green) indicates TCP/IPACT indicator(yellow):its flashing indicates data is in transmittingTX indicator(yellow):its flashing indicates it is sending data throughRX indicator(green):its flashing indicates it is receiving data throughAuxiliary output indicator(green):always(green) indicates it is in use.Lock indicator(green):always(green) indicates lock is open.POWER indicator(red): always(red) indicates control panel is powerRUN indicator(green):its flashing indicates the system works normally.CARD indicator(yellow):its flashing indicates card is punched on reader.A Use 2-conducotor power cord2)Recommended use of wires:3)The auxiliary input may be connnected to infrared body detectors,4)The auxiliary output may be connected to door bells,alarms,etc.B Use 6-conductor wire between wiegand reader and control panalC Use 4-conducotor lock power cord (RVV 4*0.75mm)D Use 2-conducotor switch power cord(RVV 2*0.5mm)communication is proper;on.alam switches,etc.Ethernet interfaceDip switchRS485 interfaceAuxiliary output1Door1Power of lockPower of control panelAACD DBB{{{{{BUTTON1 READER1 READER2+12V+12VGNDGNDWD1WD1WD0WD0GLEDGLEDBEEPBEEPINGNDACTLINK1TXRXV+POWERPCNCCOMNOCOMNONCLOCK1GNDSENV-GND485-485+AUXOUT1 LOCKGND+12V1 2 3 4ON5 6 7 81POWERCARDRUNLANSD cardAdvanced Access Controllock.through TCP/IP communication.RS485 communication.RS485 communication.(RVVP 6*0.5mm) (To choose the proper cord according to theinterface you connect, such as 6,8,10 cord.)1# Door Button1# Doorwiegand reader1# Doorwiegand reader |
Related manuals for Zksoftware C3-100
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine