aci A/FS-1 Installation And Operation Instructions Manual
Contents |
Installation and Operation InstructionsA/FS-1, A/FS-1A, A/FS-2, A/FS-2A,A/FS-3, A/FS-3A, A/FS-4, A/FS-4A,A/FS-5, A/FS-5A, A/FS-6, A/FS-6AAUTOMATION COMPONENTS, INC Version : 3.02305 Pleasant View Road I0000298Middleton, Wisconsin 53562 Page 1 of 3www.workaci.com (888) 967-5224Carefully Read These Instructions Before Installation!DescriptionElectro-mechanical, low-temperature limit/cut-out thermostat with a 20 ft, 10 ft or 6 ft capillary sensing element, auto- ormanual reset, and 1-SPDT or 2-SPDT switched output.ApplicationsThe thermostat and its capillary sensing element provide an antifreeze function. It detects temperature drops below a fixedsafety value (setpoint), i.e. heaters in A/C units, exchangers in cooling systems, etc.OperationAny 1-foot length of the sensing element subjected to temperatures below the low cut-out setpoint setting of the thermostat willactuate the thermostat switch mechanism regardless of the temperature being sensed by the remainder of the element.The low cut-out setpoint is factory set and can be adjusted by turning the slotted screw on top of the enclosure.NOTICE: The Freeze Thermostat is factory set at 40°F. This is the ideal setting that will provide the best protection whileavoiding nuisance trips.Auto-reset types will automatically switch back to the normal position if the temperature returns to normal conditions.Manual-reset types will switch back only if both the temperature returns to normal conditions and the reset button (at theenclosure’s front) is manually pushed.WiringAll wiring should comply with National and Local Electrical Codes.A M20 watertight fitting is installed in the ½” conduit knockout. If the ½” knockout is needed, remove the M20 fitting andinstall the appropriate conduit fitting in the 0.830” knockout in the bottom of the enclosure.Maximum wire size is 14 AWG (2.5mm) two copper wires. Use a screwdriver to loosen the terminal connections screws.Strip wire ends 3/8” and insert into box connectors on the switch block and securely retighten the screws.Now replace the cover and tighten the screw on the front cover.NOTICE: The Freeze Thermostat is factory set at 40°F. This is the ideal setting that will provide the best protection whileavoiding nuisance trips.InstallationLocate the sensing element where it can sense the average temperature of the space to be controlled.Locate the thermostat case where the ambient temperature is always warmer than the set point.Thermostat enclosure to be surface mounted; avoid locations subject to excessive vibration.Mount to flat surface using oval holes only. (See Wiring Diagrams) Mounting with round holes in middle of freeze statmay damage the instrument and cause improper operation.Install the capillary sensing element across the face of the coil, horizontally serpentine only. If too much of the element isvertical, it will not operate properly.Avoid sharp bends or kinks in the sensing element.Install the thermostat in an upright position so that the bellows point down and the capillary tube exits the bottom of the unit. |
manualsdatabase
Your AI-powered manual search engine