lancer 82-2684 Installation And Operation Manual
INSTRUCTION SHEETInstallation and Operation of BIB Air Vent AssemblyDATE: 12/22/98PN: 28-0011/021. MOUNTING INSTRUCTIONS1.1 WALL MOUNTThe "Bib Air Vent" assembly can be mounted directly to a wall with four (4) #8 self tapping wood screws, 3/4" long. Mountvalve assembly with vent hole up, level and square to walI.1.2 LANCER PUMP MOUNTThe "Bib Air Vent" assembly can be mounted directly to a Lancer Syrup Pump (PN 82-0109, with sold-out) by the followingmethod:A. Remove the screw indicated in Figure 1 from the left hand end cap of the Lancer pump body. Discard screw.B. Assemble connector (PN 54-0037) to "Bib Air Vent" inlet port. Secure with one (1) short screw (PN 04-0317).C. Insert connector into Lancer pump syrup outlet port. Snap fingers over sold-out device. Secure with one (1) short screw(PN 04-0317).D. Align wall mounting leg with screw hole on end cap of pump body. Secure with one (1) long screw (PN 04-0313).2. HOSE CONNECTIONSConnect pump "syrup outlet" hose into "Bib Air Vent" inlet port with 3/8" barb fitting. Connect outlet hose with 3/8" barb fitting fromoutlet port on "Bib Air Vent" to inlet port on dispenser.3. OPERATIONWhen properly connected to the discharge side of a syrup pump, the "Bib Vent" will safely remove air which has been introducedinto the system through vacuum leaks or connecting fresh Bib packages. The unwanted air accumulates in the upper chamber ofthe vent's primary reservoir and compresses due to inlet syrup pressure. As additional air is introduced, it displaces the syrup. Whenthe syrup level decreases, the primary float drops away from the seat, allowing an instant release of air to transfer through thesecondary reservoir and to the atmosphere.This cycle is repeated as additional air is introduced to the Bib system. The vent's secondary reservoir acts as a safety chamber,should the primary reservoir float fail. If syrup transfers to the secondary reservoir, instead of the air then the secondary float willrise in the transferred syrup and seal against the air's outlet seat, thereby and preventing syrup from escaping.4. CLEANING AND SANITIZINGCleaning and sanitized should be performed concurrent with sanitization of the Bib system.WARNINGALL INTERNAL PRESSURE MUST BE PURGED BEFORE REMOVING PLUGS OR DISASSEMBLY.If a more stringent cleaning is required, then the transfer tube and secondary reservoir can be sanitized by removing the clean outplugs.Figure 16655 LANCER BLVD. • SAN ANTONIO, TEXAS 78219 USA • (210) 310-7000FAX SALES• USA -CANADA – 210-310-7250 • LATIN AMERICA – 210-310-7245 • ASIA – 210-310-7242 •• EUROPE – 32-2-755-2399 • PACIFIC – 61-8-8268-1978 •FAX ENGINEERING: • 210-310-7096"Lancer" is the registered trademark of Lancer • Copyright — 1998 by Lancer, all rights reserved. |
Related manuals for lancer 82-2684
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine