nedis HCBL400WT Quick Start Manual
a Quick start guideBlood Pressure Monitor HCBL400WTFor more information see the extended manual online: ned.is/hcbl400wtIntended useThis product is intended to measure the diastolic and systolic blood pressure and pulse rateof an adult.The product is not intended for use on neonates, children or pregnant women.This product is not intended for medical use.The product is intended for indoor use only.Any modification of the product may have consequences for safety, warranty and properfunctioning.SpecificationsProduct Blood Pressure MonitorArticle number HCBL400WTDimensions (l x w x h) 136 x 120 x 61 mmWeight (excl. batteries and cuff) 225gCuff circumference 22 - 32 cmMeasuring method Oscillometric method, automatic inflation and measurementMeasurement rangeCuff pressure 0 - 300 mmHgSystolic 60 - 260 mmHgDiastolic 40 - 199 mmHgPulse rate 40 - 180 beats/minuteAccuracyPressure ± 3 mmHgPulse rate Less than 60: ±3bpmMore than 60 (incl.) : ±5%Precision 1 mmHgMemory 2 x 60 measurementsBattery type 4 x 1.5 V AA batteries (not included)Battery life Approximately 270 timesInput power 1.5 VDCOperating temperature 10 - 40 °CStorage temperature -20 - 50 °CRelative humidity ≤85 %Environmental pressure 80 - 105 kPaMain parts (image A)1 Storage bag2 Cuff3 Rubber air tube4 Air tube connector5 Battery compartment6 Memory button7 Start button8 Irregular heartbeat indicator9 Low battery indicatorq Pressure in the cuff is instable or there is a lot ofremnant air in the cuffw Blood pressure level classification indicatore Time and date displayr Systolic blood pressuret Diastolic blood pressurey Pulse rateSafety instructions- WARNING• Ensure you have fully read and understood the instructions in this document before youinstall or use the product. Keep the packaging and this document for future reference.• Only use the product as described in this document.• Do not use the product if a part is damaged or defective. Replace a damaged or defectiveproduct immediately.• Do not drop the product and avoid bumping.• Do not expose the product to water or moisture.• Only use the provided power cable.• Disconnect the product from the power source and other equipment if problems occur.• Do not unplug the product by pulling on the cable. Always grasp the plug and pull.• This product may only be serviced by a qualified technician for maintenance to reduce therisk of electric shock.• Consult with a doctor before use if you have any medical concerns.• Do not use this product in a moving vehicle. This may result in inaccurate measurements.Inserting the batteries (image B)1. Open the battery compartment A5.2. Place the batteries.3. Close A5.Setting the time and date1. Press and hold the start button A7 and the memory button A6 simultaneously for twoseconds.The time format starts to blink. The product is now in time format adjustment mode.4 If no button is pressed for 60 seconds, the product exits time and date adjustment mode.2. Press A6 to change the time format.3. Press A7 to confirm.The product is now in year adjustment mode.4. Press A6 to adjust the number.5. Press A7 to confirm.The product is now in month adjustment mode.6. Repeat steps 4 – 5 to set the month, date, hour and minutes.Connecting the cuff1. Insert the rubber air tube A3 into the air tube connector A4.4 The connector must be completely inserted to prevent air leakage during blood pressuremeasurements.Applying the cuff1. Place the cuff A2 around a bare upper arm.4 A2 must be placed 1-2 cm above the elbow joint.2. Choose an arm to measure on. Always measure on the same arm.4 If A2 is applied on the left arm, A3 must be on the inside of the arm, aligned with themiddle finger.4 If A2 is applied on the right arm, A3 must be at the side of the elbow.4 A2 should be tight but comfortable. It should be possible to insert a finger between thearm and A2.Body posture during measurementSitting down1. Sit down.2. Put your feet flat on the floor.3. Place your hand on a flat surface with the palm up.4 Do not rest your arm on A3. This may restrict the airflow to A2.4. Position your arm so A2 is at the same height as your heart.5. Sit calmly for 5 minutes before starting the blood pressure measurement.Lying down1. Lie on your back.2. Place your arm straight along your side with the palm up.3. Position your arm so A2 is at the same height as your heart.4. Lie calmly for 5 minutes before starting the blood pressure measurement.Measuring blood pressure1. Press A7.4 All symbols - A8 to Ay - are shown on the display. If not all symbols are visible, contactthe service center.The current memory group starts to blink in the place of At.4 Memory groups can be used to store measurements for multiple people on the samedevice.2. Press A6 to switch memory groups.3. Press A7 to confirm.4 The memory group is also confirmed automatically after 5 seconds of inactivity.The display shows the most recent measurements.If no measurements are stored in the memory group, the display shows zeroes.The product starts to seek zero pressure.A2 inflates until sufficient pressure has built up for a measurement.A2 slowly deflates while the measurement is carried out.The results are shown on the display.4 The measurements are automatically stored.4. Press A7 to switch off the display manually.4 The display switches off automatically after 1 minute of inactivity.Reading measurements from the memory1. Press A6.The current memory group is shown in the place of At.2. Press A7 to switch memory groups.3. Press A6 to confirm.4 The memory group is also confirmed automatically after 5 seconds of inactivity.The display shows the average values of all measurements in the current memory group.If no measurements are stored in the memory group, the display shows zeroes.4. Press A6 to show the average values of the last three measurements in the currentmemory group.5. Press A6 to show the number of stored measurements in the current memory group.6. Press A6 to show the most recent measurements.7. Press A6 repeatedly to show the previous measurements.8. Press A7 to switch off the display manually.4 The display switches off automatically after 1 minute of inactivity.Deleting measurements from the memory1. When the display shows a measurement, press and hold A6 for three seconds to deleteall measurements in the current memory bank.Technical alarmIf the measured blood pressure is outside the rated range, the display shows ‘Hi’ or ‘Lo’ astechnical alarm.1. Check if the measurement was performed correctly.2. If the measurement was performed correctly, consult your physician. |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine