Manuals database logo
manualsdatabase
Your AI-powered manual search engine

OHAUS Carat PAJ2003 manuals

Carat PAJ2003 first page preview

Carat PAJ2003

Brand: OHAUS | Category: Scales
Table of contents
  1. Introduction
  2. Tools and Test Equipment Required
  3. specifications
  4. Balance Operation
  5. Overview of the Display Indicators
  6. Power On
  7. The Load Cell
  8. Connecting the RS232 Interface
  9. RS232 Commands
  10. Troubleshooting
  11. Diagnostic Guide
  12. Error Codes
  13. Preventive Maintenance
  14. Variations in Opening Pioneer Models
  15. Load Cell Removal and Disassembly
  16. Disassembly of Precision Balances with Internal Calibration
  17. Removing Internal Calibration Weights
  18. Reassembling the Internal Calibration Mechanism
  19. Proper manner to grasp Load Cell when removing Weight Arm assembly
  20. Service Fixture, screws and washers for 150g to 310g Precision balances
  21. Precision Load Cell top
  22. Position Sensor Board
  23. Hanger
  24. Magnets must be clean
  25. Service Fixture for 510g to 4100g Precision Load Cell, attached to Hanger
  26. Sideways Motion Stop Plate
  27. When Position Sensor Board shows normal weight, tighten its screws
  28. Removing the InCal Mechanism from InCal Analytical Balances
  29. Bottom Housing with Load Cell, Weight Arms and Weights removed
  30. Re-Installing Internal Calibration Components
  31. Disassembling Analytical Load Cells
  32. Shims are inserted between the Hanger and the Load Cell
  33. Vertical Flexure and screws, Lock Plate, washers, and bushings, removed
  34. Hanger with two screws
  35. Contact Board with 3-wire ribbon cable soldered to it
  36. A screw connects the Contact Board to the Load Cell
  37. Position Sensor PC Board Removal/Replacement/Adjustment - Analytical
  38. Reassembling Analytical Load Cells
  39. Installing the Magnet Half
  40. Insert shims between the Hanger and the Load Cell on both sides
  41. Analytical InCal Load Cell with Top Bracket visible
  42. Block Style Load Cell
  43. Progressive Disassembly of Block Style Load Cells
  44. Internal Calibration Testing
  45. InCal Mechanism Removal
  46. InCal Mechanism Installation
  47. Removing Position Sensor
  48. Removing the Block Style Load Cell from the Base Plate
  49. Installing the Block Style Load Cell on the Base Plate
  50. Removal and Installation of the Block Style Load Cell PC Board
  51. Load Cell PCB-Temperature Sensor-Position Sensor assembly
  52. Removing the Ratio Beam on Block Style Load Cells
  53. Contact Board with cover holder off
  54. Weight Arm Screws and Washers removed
  55. Aluminum Sleeves removed
  56. Installing the Ratio Beam on Block Style Load Cells
  57. Ratio Beam Vane Slotted Area
  58. Installing the InCal Weight Arm
  59. Centering pins in Ratio Beam
  60. Installing the Load Cell PCB-Temperature Sensor-Position Sensor
  61. Position Sensor on the Magnet
  62. Setting the Up/Down Stop Screw on Block Style Load Cells
  63. Test Masses Required
  64. Performance Tests
  65. Off-Center Load Test
  66. Off-Center Load Adjustment for Precision Models
  67. Off-Center Load Adjustment for Analytical Models
  68. Off-Center Load Adjustment for Block Style Models
  69. Repeatability Test
  70. Repeatability Worksheet
  71. Linearity Test