Daikin FTKS50D2V1W manuals
FTKS50D2V1W
Table of contents
FTKS50D2V1W
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- Part 1 List of Functions
- List of Functions
- Heat Pump Models
- Part 2 Specifications
- Specifications
- Outdoor Units - Cooling Only
- Indoor Units - Heat Pump
- Outdoor Units - Heat Pump
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Printed Circuit Board Connector Wiring Diagram
- Duct Connected Type
- Floor / Ceiling Suspended Dual Type
- Floor Standing Type
- Ceiling Suspended Type
- Outdoor Units
- Part 4 Function and Control
- Main Functions
- Power-Airflow Dual Flaps, Wide Angle Louvers and Auto-Swing
- Operation Starting Control
- Fan Speed Control for Indoor Units
- Programme Dry Function
- Automatic Operation
- Thermostat Control
- Night Set Mode
- ECONO Mode
- INTELLIGENT EYE (Wall Mounted Type only)
- HOME LEAVE Operation
- Inverter POWERFUL Operation
- Other Functions
- Function of Main Structural Parts
- Function of Thermistor
- cooling only model
- Control Specification
- Frequency Control
- Controls at Mode Changing / Start-up
- compressor protection function
- Discharge Pipe Control
- Freeze-up Protection Control
- Fan Control
- Defrost Control
- Electronic Expansion Valve Control
- Malfunctions
- Forced Operation Mode
- Wiring-Error Check
- Additional Function
- Part 5 Operation Manual
- System Configuration
- Instruction
- safety precautions
- FVXS Series
- air flow selection
- FHQ Series
- temperature setting
- Part 6 Service Diagnosis
- Caution for Diagnosis
- Problem Symptoms and Measures
- Service Check Function
- Check Method 2
- Code Indication on the Remote Control
- Troubleshooting
- Indoor Unit PCB Abnormality
- Freeze-up Protection Control or High Pressure Control
- Fan Motor or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Front Panel Open / Close Fault
- Signal Transmission Error (between Indoor and Outdoor Unit)
- Unspecified Voltage (between Indoor and Outdoor Units)
- Outdoor Unit PCB Abnormality
- OL Activation (Compressor Overload)
- Compressor Lock
- DC Fan Lock
- Input Over Current Detection
- Discharge Pipe Temperature Control
- High Pressure Control in Cooling
- Compressor Sensor System Abnormality
- Position Sensor Abnormality
- CT or Related Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- SiENBE12
- Electrical Box Temperature Rise
- Radiation Fin Temperature Rise
- Output Over Current Detection
- Insufficient Gas
- Low-voltage Detection or Over-voltage Detection
- Signal Transmission Error (on Outdoor Unit PCB)
- Check
- electronic expansion valve check
- four way valve performance check
- installation condition check
- discharge pressure check
- power supply waveforms check
- capacitor voltage check
- main circuit electrolytic capacitor check
- hall ic check
- Part 7 Removal Procedure
- Outdoor Unit
- Removal of the Electrical Box
- Removal of the PCB
- Removal of the Propeller Fan / Fan Motor
- Removal of the Sound Blanket
- Removal of Electronic Expansion Valve Coil Four Way Valve Coil and Thermistor
- Removal of the Distributor
- Removal of the Four Way Valve
- Removal of the Compressor
- Part 8 Others
- Others
- Jumper Settings
- Part 9 Appendix
- Piping Diagrams
- Wiring Diagrams