Manuals database logo
manualsdatabase
Your AI-powered manual search engine

Datalogic QuickScan I QM21X1 manuals

QuickScan I QM21X1 first page preview

QuickScan I QM21X1

Brand: Datalogic | Category: Barcode Reader
Table of contents
  1. Table Of Contents
  2. Table Of Contents
  3. Table Of Contents
  4. Table Of Contents
  5. Table Of Contents
  6. Table Of Contents
  7. Table Of Contents
  8. Table Of Contents
  9. INTRODUCTION
  10. Manual Conventions
  11. SETUP
  12. Setting Up the Reader
  13. Locking the Reader to the Base
  14. System and Network Layout
  15. Linking the Reader to a Base Station
  16. Using the BC20xx™ Radio Base
  17. Charging the Battery Pack
  18. Battery Safety
  19. Replacing the Battery Pack
  20. Programming
  21. Resetting the Product Configuration to Defaults
  22. INTERFACES
  23. CONFIGURATION USING BAR CODES
  24. Configuration Parameters
  25. Global Interface Features
  26. USB Suspend Mode
  27. RS-232 ONLY Interface
  28. Baud Rate
  29. Data Bits
  30. Stop Bits
  31. Parity
  32. Handshaking Control
  33. RS-232/USB-COM Interfaces
  34. Intercharacter Delay
  35. Beep On ASCII BEL
  36. ACK NAK Options
  37. ACK Character
  38. ACK NAK Timeout Value
  39. ACK NAK Retry Count
  40. ACK NAK Error Handling
  41. Indicate Transmission Failure
  42. Enable Character
  43. Keyboard Interface
  44. Country Mode
  45. Caps Lock State
  46. Numlock
  47. Keyboard Send Control Characters
  48. Wedge Quiet Interval
  49. Intercode Delay
  50. USB Keyboard Speed
  51. USB-OEM Interface
  52. USB-OEM Device Usage
  53. Data Format
  54. Global Prefix/Suffix
  55. Global AIM ID
  56. Label ID
  57. Label ID: Set Individually Per Symbology
  58. Label ID Symbology Selection
  59. Set Global Mid Label ID Character(s)
  60. Case Conversion
  61. Character Conversion
  62. Reading Parameters
  63. Double Read Timeout
  64. Label Gone Timeout
  65. LED and Beeper Indicators
  66. Good Read: When to Indicate
  67. Good Read Beep Type
  68. Good Read Beep Length
  69. Illumination Control
  70. Good Read Beep Volume
  71. Good Read LED Duration
  72. Scanning Features
  73. Stand Mode Triggered Timeout
  74. Scanning Active Time
  75. Flash On Time
  76. Flash Off Time
  77. Stand Mode Sensitivity
  78. Green Spot Duration
  79. Symbologies
  80. Disable All Symbologies
  81. UPC-A
  82. Expand UPC-A to EAN-13
  83. In-Store Minimum Reads
  84. UPC-E
  85. Expand UPC-E to EAN-13
  86. UPC-E Number System Character Transmission
  87. EAN 13 Enable/Disable
  88. EAN-13 Flag 1 Character
  89. ISSN Enable/Disable
  90. EAN 8 Enable/Disable
  91. EAN 8 Both Guards Substitution
  92. EAN 8 Guard Insertion
  93. EAN 8 Minimum Segment Length Block
  94. EAN 8 Minimum Reads
  95. EAN 8 Stitch Exact Label Halves
  96. EAN Two Label
  97. EAN Two Label Minimum Reads
  98. UPC/EAN Global Settings
  99. UPC/EAN Correlation
  100. UPC/EAN Price Weight Check
  101. UPC-A Minimum Reads
  102. UPC/EAN Guard Insertion
  103. UPC/EAN Stitch Unlike Label Halves
  104. UPC/EAN Minimum Segment Length
  105. Add-Ons
  106. Optional Add-On Timer
  107. P2 Add-Ons Minimum Reads
  108. P5 Add-Ons Minimum Reads
  109. GS1-128 Add-Ons Minimum Reads
  110. GS1 DataBar Omnidirectional Enable/Disable
  111. GS1 DataBar Omnidirectional Minimum Reads
  112. GS1 DataBar Expanded Enable/Disable
  113. GS1 DataBar Expanded Minimum Reads
  114. GS1 DataBar Expanded Length Control
  115. GS1 DataBar Expanded Set Length 1
  116. GS1 DataBar Expanded Set Length 2
  117. GS1 DataBar Limited Enable/Disable
  118. GS1 DataBar Limited Minimum Reads
  119. Code 39 Enable/Disable
  120. Code 39 Check Character Calculation
  121. Code 39 Check Character Transmission
  122. Code 39 Full ASCII
  123. Code 39 Quiet Zones
  124. Code 39 Minimum Reads
  125. Code 39 Decoding Level
  126. Code 39 Length Control
  127. Code 39 Set Length 1
  128. Code 39 Set Length 2
  129. Code 39 Interdigit Ratio
  130. Code 39 Character Correlation
  131. Code 32 (Italian Pharmaceutical)
  132. Code 32 Check Character Transmission
  133. Code 39 CIP (French Pharmaceutical)
  134. Expand Code 128 to Code 39
  135. Code 128 Function Character Transmission
  136. Code 128 Quiet Zones
  137. Code 128 Minimum Reads
  138. Code 128 Decoding Level
  139. Code 128 Length Control
  140. Code 128 Set Length 1
  141. Code 128 Set Length 2
  142. Code 128 Character Correlation
  143. GS1-128 Enable
  144. I 2 of 5 Enable/Disable
  145. I 2 of 5 Check Character Calculation
  146. I 2 of 5 Check Character Transmission
  147. i 2 of 5 decoding level
  148. i 2 of 5 length control
  149. I 2 of 5 Character Correlation
  150. Interleaved 2 of 5 CIP HR
  151. Datalogic 2 of 5
  152. Datalogic 2 of 5 Check Character Transmission
  153. Datalogic 2 of 5 Decoding Level
  154. Datalogic 2 of 5 Set Length 1
  155. Datalogic 2 of 5 Set Length 2
  156. Datalogic 2 of 5 Interdigit Maximum Ratio
  157. Datalogic 2 of 5 Character Correlation
  158. Codabar
  159. Codabar Check Character Calculation
  160. Codabar Check Character Transmission
  161. Codabar Start/Stop Character Set
  162. Codabar Quiet Zones
  163. Codabar Minimum Reads
  164. Codabar Decoding Level
  165. Codabar Length Control
  166. Codabar Set Length 1
  167. Codabar Set Length 2
  168. Codabar Interdigit Ratio
  169. Codabar Character Correlation
  170. ABC Codabar
  171. ABC Codabar Dynamic Concatenation Timeout
  172. ABC Codabar Force Concatenation
  173. Code 11 Check Character Calculation
  174. Code 11 Minimum Reads
  175. Code 11 Length Control
  176. Code 11 Set Length 1
  177. Code 11 Set Length 2
  178. Code 11 Interdigit Ratio
  179. Code 11 Decoding Level
  180. Code 11 Character Correlation
  181. Standard 2 of
  182. Standard 2 of 5 Check Character Transmission
  183. Standard 2 of 5 Decoding Level
  184. Standard 2 of 5 Set Length 1
  185. Standard 2 of 5 Set Length 2
  186. Standard 2 of 5 Character Correlation
  187. Industrial 2 of 5
  188. Industrial 2 of 5 Check Character Transmission
  189. Industrial 2 of 5 Set Length 1
  190. Industrial 2 of 5 Set Length 2
  191. Industrial 2 of 5 Minimum Reads
  192. Industrial 2 of 5 Stitching
  193. IATA
  194. ISBT 128
  195. ISBT 128 Dynamic Concatenation Timeout
  196. ISBT 128 Force Concatenation
  197. MSI Enable/Disable
  198. MSI Check Character Transmission
  199. MSI Set Length 1
  200. MSI Set Length 2
  201. MSI Minimum Reads
  202. MSI Decoding Level
  203. Code 93 Enable/Disable
  204. Code 93 Check Character Transmission
  205. Code 93 Set Length 1
  206. Code 93 Set Length 2
  207. Code 93 Minimum Reads
  208. Code 93 Decoding Level
  209. Code 93 Quiet Zones
  210. Code 93 Stitching
  211. Codablock F
  212. Codablock F AIM Check
  213. Codablock F Set Length 1
  214. Codablock F Set Length 2
  215. Code
  216. Code 4 Hex to Decimal Conversion
  217. Code 5 Check Character Transmission
  218. Code 4 and Code 5 Common Configuration Items
  219. Code 4 and Code 5 Minimum Reads
  220. Follett 2 of
  221. BC412 Check Character Calculation
  222. BC412 Decoding Level
  223. BC412 Length Control
  224. BC412 Set Length 1
  225. BC412 Set Length 2
  226. Plessey
  227. Plessey Check Character Calculation
  228. Plessey Length Control
  229. Plessey Set Length 1
  230. Plessey Set Length 2
  231. Plessey Minimum Reads
  232. Plessey Decoding Level
  233. Plessey Stitching
  234. wireless features
  235. wireless beeper features
  236. beep duration
  237. beep volume
  238. docking beep
  239. configuration updates
  240. copy configuration to base station
  241. send batch
  242. rf batch mode transmit delay
  243. direct radio autolink
  244. rf address stamping
  245. source radio address delimiter character
  246. bt security features
  247. select pin code length
  248. other bt features
  249. powerdown timeout
  250. features for star models only
  251. star radio transmit mode
  252. MESSAGE FORMATTING
  253. LED and Beeper Control
  254. REFERENCES
  255. RS-232 Parameters
  256. NAK Character
  257. Disable Character
  258. Keyboard Wedge
  259. Data Editing
  260. Label ID: Pre-loaded Sets
  261. Scan Mode
  262. Symbology Settings
  263. Set Length
  264. RF Features
  265. BT-Only Features
  266. TECHNICAL SPECIFICATIONS
  267. LED and Beeper Indications
  268. Programming Mode
  269. STANDARD DEFAULTS
  270. Default Exceptions
  271. SAMPLE BAR CODES
  272. GS1 DataBar (RSS)
  273. KEYPAD
  274. SCANCODE TABLES
  275. Interface Type PC AT PS/2 or USB-Keyboard
  276. Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode
  277. Digital Interface
  278. Microsoft Windows Codepage 1252
  279. INDEX
  280. ascii chart
Related products
QuickScan QM21X1QuickScan I QM2131QuickScan I QBT21X1Quickscan IQuickScan QM24XXQuickScan QM2500QuickScan QM2400QuickScan QM2430QuickScan I QM21 1 SeriesQuickScan I QM24 Series
Datalogic categories
More Datalogic categories
Manuals database logo
manualsdatabase
Your AI-powered manual search engine