Daikin RXS35L2V1B manuals
RXS35L2V1B
Table of contents
- Part 1 List of Functions ................................................................ 1
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- Part 1 List of Functions
- Functions
- Part 2 Specifications
- Specifications
- Heat Pump
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Indoor Unit
- Outdoor Unit
- RK(X)S25/35G2V1B
- rxs35k2v1b, rxs35l2v1b
- Main Functions
- Airflow Direction Control
- Program Dry Operation
- Automatic Operation
- Thermostat Control
- NIGHT SET Mode
- HOME LEAVE Operation
- Inverter POWERFUL Operation
- Clock Setting
- Other Functions
- Function of Thermistor
- Control Specification
- Frequency Control
- Controls at Mode Changing / Start-up
- compressor protection function
- Discharge Pipe Temperature Control
- Input Current Control
- Freeze-up Protection Control
- Outdoor Fan Control
- Defrost Control
- Electronic Expansion Valve Control
- pressure equalizing control
- Malfunctions
- Part 5 Remote Controller
- Remote Controller
- mode button
- Service Diagnosis
- Table Of Contents
- General Problem Symptoms and Check Items
- Troubleshooting with LED
- Service Diagnosis
- Troubleshooting
- Indoor Unit PCB Abnormality
- Freeze-up Protection Control / Heating Peak-cut Control
- Fan Motor (AC Motor) or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Refrigerant Shortage
- Low-voltage Detection or Over-voltage Detection
- Signal Transmission Error (Between Indoor Unit and Outdoor Unit)
- Unspecified Voltage (Between Indoor Unit and Outdoor Unit)
- Outdoor Unit PCB Abnormality
- OL Activation (Compressor Overload)
- Compressor Lock
- DC Fan Lock
- Input Overcurrent Detection
- Four Way Valve Abnormality
- High Pressure Control in Cooling
- Compressor System Sensor Abnormality
- Position Sensor Abnormality
- DC Voltage / Current Sensor Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- Electrical Box Temperature Rise
- Radiation Fin Temperature Rise
- Output Overcurrent Detection
- Check
- Hall IC Check
- Electronic Expansion Valve Check
- Four Way Valve Performance Check
- Inverter Analyzer Check
- Rotation Pulse Check on the Outdoor Unit PCB
- Installation Condition Check
- Discharge Pressure Check
- Main Circuit Short Check
- Power Module Check
- Pump Down Operation
- Forced Cooling Operation
- Trial Operation
- Field Settings
- Facility Setting Jumper (cooling at low outdoor temperature)
- Jumper and Switch Settings
- Silicon Grease on Power Transistor / Diode Bridge
- Part 8 Appendix
- Piping Diagrams
- heat pump
- Wiring Diagrams
RXS35L2V1B
Table of contents
- part 1 list of functions
- Table Of Contents
- Table Of Contents
- safety cautions
- list of functions
- Functions
- Part 2 Specifications
- Specifications
- Heat Pump
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Indoor Unit
- Outdoor Unit
- RK(X)S25/35G2V1B
- RK(X)S25/35G2V1B9, RXS25/35J2V1B, RXS25K3V1B, RXS35K2V1B RXS25/35L2V1B
- RXS25/35L3V1B
- Part 4 Functions and Control
- main functions
- airflow direction control
- program dry operation
- automatic operation
- thermostat control
- night set mode
- home leave operation
- inverter powerful operation
- clock setting
- other functions
- Thermistor Functions
- control specification
- frequency control
- Controls at Mode Changing / Start-up
- compressor protection function
- Discharge Pipe Temperature Control
- input current control
- Freeze-up Protection Control
- outdoor fan control
- defrost control
- electronic expansion valve control
- pressure equalizing control
- Malfunctions
- part 5 remote controller
- remote controller
- mode button
- Part 6 Service Diagnosis
- general problem symptoms and check items
- troubleshooting with led
- service diagnosis
- troubleshooting
- indoor unit pcb abnormality
- Freeze-up Protection Control / Heating Peak-cut Control
- Fan Motor (AC Motor) or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- refrigerant shortage
- Low-voltage Detection or Over-voltage Detection
- Signal Transmission Error (Between Indoor Unit and Outdoor Unit)
- Unspecified Voltage (Between Indoor Unit and Outdoor Unit)
- outdoor unit pcb abnormality
- OL Activation (Compressor Overload)
- compressor lock
- dc fan lock
- input overcurrent detection
- four way valve abnormality
- high pressure control in cooling
- compressor system sensor abnormality
- position sensor abnormality
- DC Voltage / Current Sensor Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- electrical box temperature rise
- radiation fin temperature rise
- output overcurrent detection
- thermistor resistance check
- hall ic check
- electronic expansion valve check
- four way valve performance check
- inverter analyzer check
- rotation pulse check on the outdoor unit pcb
- installation condition check
- outdoor fan system check
- power module check
- Part 7 Trial Operation and Field Settings
- pump down operation
- trial operation
- field settings
- Facility Setting Jumper (cooling at low outdoor temperature)
- jumper and switch settings
- Silicone Grease on Power Transistor / Diode Bridge
- Part 8 Appendix
- piping diagrams
- Wiring Diagrams
manualsdatabase
Your AI-powered manual search engine