Daikin Super Multi Plus E-Series FTXG35JV1BW manuals
Super Multi Plus E-Series FTXG35JV1BW
Table of contents
- Part 1 List of Functions ................................................................ 1
- part 1 list of functions
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- list of functions
- Functions
- Part 2 Specifications
- specifications
- indoor unit
- floor standing type
- duct connected type
- ceiling mounted cassette type
- ceiling suspended type
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Outdoor Unit
- BPMKS967B2B/B3B
- Floor Standing Type
- Floor / Ceiling Suspended Dual Type
- Duct Connected Type
- Ceiling Mounted Cassette Type
- Ceiling Mounted Built-in Type
- Ceiling Suspended Type
- remote controller
- wireless remote controller
- Part 4 Refrigerant Circuit
- refrigerant circuit
- functional parts layout
- refrigerant flow for each operation mode
- heating operation
- cooling oil return operation
- Heating Oil Return Operation & Defrost Operation
- Function
- Part 5 Function
- Table Of Contents
- operation mode
- basic control
- compressor pi control
- electronic expansion valve pi control
- cooling operation fan control
- special control
- oil return operation
- defrosting operation
- Pump-down Residual Operation
- restart standby
- protection control
- low pressure protection control
- Discharge Pipe Temperature Protection Control
- inverter protection control
- Freeze-up Protection Control
- dew condensation prevention control
- other control
- bp unit control
- bp unit electronic expansion valve control
- sh control in cooling operation
- sc control in heating operation
- temperature control
- operation starting control
- airflow direction control
- fan speed control for indoor units
- program dry operation
- automatic operation
- thermostat control
- night set mode
- econo operation
- home leave operation
- Area INTELLIGENT EYE Operation
- intelligent eye operation
- inverter powerful operation
- other functions
- weekly timer operation
- drain pump control
- thermostat sensor in remote controller
- freeze prevention control
- Hot Start Control (In Heating Operation Only)
- Part 6 Test Operation and Field Settings
- test operation
- check operation
- operation when power is turned on
- outdoor unit pcb layout
- RA Indoor Unit - F(C)TXG, FTXS, FVXS, FLXS, FDXS Series
- check points
- field settings
- model type setting
- jumper and switch settings
- Part 7 Operation Manual
- Part 7 Operation Manual
- system configuration
- name of parts
- signal transmitter
- mode selector button
- fan operation
- operating conditions
- adjusting the airflow direction and rate
- comfort airflow operation
- powerful operation
- outdoor unit quiet operation
- off timer operation
- on timer operation
- note for multi system
- FTXS-G, FVXS Series - ARC452A1, A3
- names of parts
- names of parts
- opening the front panel
- to change the airflow rate setting
- adjusting the airflow direction
- comfort airflow and intelligent eye operation
- timer operation
- FTXG-E, CTXG-E, FTXS-F, FLXS, FDXS Series ARC433B41, B67, B69, B70
- Remote Controller
- Table Of Contents
- to change the air flow rate setting
- adjusting the air flow direction
- to use on timer operation
- BRC1E51A7
- names and functions
- automatic operation mode
- basic operation method
- program dry
- key lock
- airflow direction
- ventilation mode
- schedule timer
- holiday setting
- convenient functions
- clock setting
- useful information
- BRC7E530W, BRC7F532F, BRC7EA63W
- operation range
- operation procedure
- Troubleshooting
- Part 8 Troubleshooting
- Table Of Contents
- troubleshooting with led
- operation lamp
- service check function
- 3. Error Codes and Description
- error codes and description
- troubleshooting for ra indoor unit
- Freeze-up Protection Control or Heating Peak-cut Control
- fan motor or related abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Front Panel Open / Close Fault
- fan motor connector output check
- thermistor resistance check
- hall ic check
- Troubleshooting for SA Indoor Unit
- Drain Water Level System Abnormality
- Fan Motor or Related Abnormality (FHQ Series)
- Swing Motor Lock (FHQ Series)
- Drain System Abnormality
- Indoor Liquid Pipe Thermistor (R2T) Abnormality
- Indoor Heat Exchanger Thermistor (R3T) Abnormality
- Suction Air Thermistor (R1T) Abnormality
- Remote Controller Thermistor Abnormality
- Transmission Error between Remote Controller and Indoor Unit
- Transmission Error between Main and Sub Remote Controllers
- Field Setting Switch Abnormality
- troubleshooting for bp unit
- BP Unit PCB Abnormality
- BP Liquid or Gas Pipe Thermistor Abnormality
- transmission error between indoor unit and bp unit
- transmission error between outdoor unit and bp unit
- power supply waveforms check
- troubleshooting for outdoor unit
- actuation of high pressure switch
- actuation of low pressure sensor
- compressor motor lock
- Outdoor Fan Motor Abnormality
- Moving Part of Electronic Expansion Valve (Y1E, Y3E) Abnormality
- Discharge Pipe Temperature Abnormality
- refrigerant overcharged
- Outdoor Temperature Thermistor (R1T) Abnormality
- Discharge Pipe Thermistor (R2T) Abnormality
- Suction Pipe Thermistor (R3T, R5T) Abnormality
- Outdoor Heat Exchanger Thermistor (R4T) Abnormality
- Outdoor Liquid Pipe Thermistor (R7T) Abnormality
- Subcooling Heat Exchanger Gas Pipe Thermistor (R6T Abnormality
- High Pressure Sensor Abnormality
- Low Pressure Sensor Abnormality
- Outdoor Unit PCB Abnormality
- radiation fin temperature rise
- Inverter Compressor Abnormality
- Inverter Current Abnormality
- Compressor Start-up Error
- high voltage of capacitor in main inverter circuit
- Radiation Fin Thermistor Abnormality
- Low Pressure Drop due to Refrigerant Shortage or Electronic Expansion Valve Abnormality
- power supply insufficient or instantaneous failure
- Check Operation is not Conducted
- Transmission Error Between Indoor Unit and Outdoor Unit in the Same System
- excessive number of indoor units
- Address Duplication of Central Remote Controller
- Transmission Error between Centralized Remote Controller and Indoor Unit
- system is not set yet
- System Abnormality, Refrigerant System Address Undefined
- Check for Outdoor Unit
- troubleshooting
- fan motor connector check
- Thermistor Resistance / Temperature Characteristics
- pressure sensor
- Method of Replacing Inverter's Power Transistors Modules
- Part 9 Removal Procedure
- removal of outer panels
- Removal of PCBs / Electrical Components
- Removal of Outdoor Fans / Fan Motors
- Removal of Thermistors
- Removal of Electronic Expansion Valves / Peripheral Equipments
- removal of four way valve
- removal of compressor
- Removal of PCB Assembly
- Removal of Electronic Expansion Valve Coils
- Part 10 Appendix
- piping diagrams
- wiring diagrams
Related products
Super Multi Plus E-Series FTXG35JV1BWSSuper Multi Plus E-Series FTXG25JV1BWSuper Multi Plus E-Series FTXG35EV1BWSuper Multi Plus E-Series FTXG25JV1BWSSuper Multi Plus E-Series FTXG35EV1BWSSuper Multi Plus E-Series FTXG25EV1BWSuper Multi Plus E-Series FTXG25EV1BWSSuper Multi Plus E-Series CTXG50JV1BWSuper Multi Plus E-SeriesSuper Multi Plus E-Series FTXS60FV1BDaikin categories
Air Conditioner
Heat Pump
Chiller
Air Handlers
Inverter
Fan
Heating System
Remote Control
Air conditioning
Boiler
manualsdatabase
Your AI-powered manual search engine