Daikin VRV II RXYQ14MY1B manuals
VRV II RXYQ14MY1B
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- Part 1 General Information
- Model Names of Indoor/Outdoor Units
- External Appearance
- Outdoor Units
- Combination of Outdoor Units
- Model Selection
- Part 2 Specifications
- Specifications
- Indoor Units
- ceiling suspended type
- Part 3 Refrigerant Circuit
- Refrigerant Circuit
- Outdoor air processing unit FXMQ125~250MFV1
- Functional Parts Layout
- RXYQ8, 10, 12M
- RXYQ14, 16M
- Refrigerant Flow for Each Operation Mode
- Part 4 Function
- Function general
- Operation Mode
- Basic Control
- Compressor PI Control
- Electronic Expansion Valve PI Control
- Cooling Operation Fan Control
- SiE39
- Oil Return Operation
- Defrosting Operation
- Pump-down Residual Operation
- Restart Standby
- Stopping Operation
- Pressure Equalization prior to Startup
- Protection Control
- Low Pressure Protection Control
- Discharge Pipe Protection Control
- Inverter Protection Control
- STD Compressor Overload Protection
- Other Control
- Emergency Operation
- Demand Operation
- Outline of Control (Indoor Unit)
- remote controller
- Louver Control for Preventing Ceiling Dirt
- Thermostat Sensor in Remote Controller
- Freeze Prevention
- Control of outdoor air Processing unit (Unique Control for Outdoor Air Processing Unit)
- Part 5 Test Operation
- Test Operation
- Operation When Power is Turned On
- Outdoor Unit PC Board Layout
- Field Setting
- detailed explanation of setting modes
- Field Setting from Outdoor Unit
- Part 6 Troubleshooting
- Troubleshooting by Remote Controller
- Self-diagnosis by Wired Remote Controller
- Self-diagnosis by Wireless Remote Controller
- Operation of The Remote Controller's Inspection Test Operation Button
- Remote Controller Service Mode
- Remote Controller Self-Diagnosis Function
- malfunction code indication by outdoor unit pcb
- Troubleshooting by Indication on the Remote Controller
- A1" Indoor Unit: PC Board Defect
- A3" Indoor Unit: Malfunction of Drain Level Control System (S1L)
- A6" Indoor Unit: Fan Motor (M1F) Lock, Overload
- A7" Indoor Unit: Malfunction of Swing Flap Motor (MA)
- A9" Indoor Unit: Malfunction of Moving Part of Electronic Expansion Valve (20E)
- AF" Indoor Unit: Drain Level above Limit
- AJ" Indoor Unit: Malfunction of Capacity Determination Device
- C4" Indoor Unit: Malfunction of Thermistor (R2T) for Heat Exchanger
- C5" Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes
- C9" Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air
- CJ" Indoor Unit: Malfunction of Thermostat Sensor in Remote Controller
- E1" Outdoor Unit: PC Board Defect
- E3" Outdoor Unit: Actuation of High Pressure Switch
- E4" Outdoor Unit: Actuation of Low Pressure Sensor
- E5" Compressor Motor Lock
- E6" Compressor Motor Overcurrent/Lock
- E7" Malfunction of Outdoor Unit Fan Motor
- E9" Outdoor Unit: Malfunction of Moving Part of Electronic Expansion Valve (Y1E, Y2E)
- F3" Outdoor Unit: Abnormal Discharge Pipe Temperature
- F6" Refrigerant Overcharged
- H7" Abnormal Outdoor Fan Motor Signal
- H9" Outdoor Unit: Malfunction of Thermistor for Outdoor Air (R1T)
- J2" Current Sensor Malfunction
- J5" Outdoor Unit: Malfunction of Thermistor (R2T) for Suction Pipe
- J6" Outdoor Unit: Malfunction of Thermistor (R4T) for Outdoor Unit Heat Exchanger
- J8" Malfunction of Oil Equalizing Pipe Thermistor (R7T)
- J9" Malfunction of Receiver Gas Pipe Thermistor (R5T)
- JA" Outdoor Unit: Malfunction of Discharge Pipe Pressure Sensor
- JC" Outdoor Unit: Malfunction of Suction Pipe Pressure Sensor
- L4" Outdoor Unit: Malfunction of Inverter Radiating Fin Temperature Rise
- L5" Outdoor Unit: Inverter Compressor Abnormal
- L8" Outdoor Unit: Inverter Current Abnormal
- L9" Outdoor Unit: Inverter Start up Error
- LC" Outdoor Unit: Malfunction of Transmission Between Inverter and Control PC Board
- P1" Outdoor Unit: Inverter Over-Ripple Protection
- P4" Outdoor Unit: Malfunction of Inverter Radiating Fin Temperature Rise Sensor
- UO" Low Pressure Drop Due to Refrigerant Shortage or Electronic Expansion Valve Failure
- U1" Reverse Phase, Open Phase
- U2" Power Supply Insufficient or Instantaneous Failure
- U3" Check Operation not executed
- U4" Malfunction of Transmission Between Indoor Units
- U5" Malfunction of Transmission Between Remote Controller and Indoor Unit
- U7" Malfunction of Transmission Between Outdoor Units
- U8" Malfunction of Transmission Between Master and Slave Remote Controllers
- UA" Excessive Number of Indoor Units
- UC" Address Duplication of Central Remote Controller
- UE" Malfunction of Transmission Between Central Remote Controller and Indoor Unit
- UF" Refrigerant System not Set, Incompatible Wiring/Piping
- UH" Malfunction of System, Refrigerant System Address Undefined
- Troubleshooting (OP: Central Remote Controller)
- M1" PC Board Defect
- M8" Malfunction of Transmission Between Optional Controllers for Centralized Control
- MA" Improper Combination of Optional Controllers for Centralized Control
- MC" Address Duplication, Improper Setting
- Troubleshooting (OP: Schedule Timer)
- Troubleshooting (OP: Unified ON/OFF Controller)
- repeats double blink
- Part 7 Replacement procedure for INV compressor VRV II (RXYQ5M to 48M)
- Replacement procedure for INV compressor VRV II (RXYQ5M-48M)
- Part 8 Appendix
- Piping Diagrams
- Indoor Unit
- Wiring Diagrams for Reference
- Field Wiring
- List of Electrical and Functional Parts
- Indoor Side
- Option List
- system configuration
- Option Lists (Outdoor Unit)
- Piping Installation Point
- The Example of A Wrong Pattern
- Selection of Pipe Size, Joints and Header
- RXYQ34MY1B, RXYQ36MY1B, RXYQ38MY1B, RXYQ40MY1B RXYQ42MY1B, RXYQ44MY1B, RXYQ46MY1B, RXYQ48MY1B
- outdoor unit multi connection piping kit
- Thermistor Resistance / Temperature Characteristics
- Pressure Sensor
- Method of Replacing The Inverter's Power Transistors and Diode Modules
- Part 9 Precautions for New Refrigerant (R410)
- Precautions for New Refrigerant (R410)
- Refrigerant Cylinders
- Service Tools
Related products
VRV II RXYQ44MY1BVRV II RXYQ16MY1BVRV II RXYQ24MY1BVRV II RXYQ34MY1BVRV II RXYQ10MY1BVRV II RXYQ18MY1BVRV II RXYQ12MY1BVRV II RXYQ5MY1BVRV II RXYQ8MY1BVRV II RXYQ20MY1BDaikin categories
Air Conditioner
Heat Pump
Chiller
Air Handlers
Inverter
Fan
Heating System
Remote Control
Air conditioning
Boiler