Lift Cabin Audio Unit – Compact 2.344CANCEL Input Connection (Door Contact, Optional)This input helps cancel a rescue request if the lift is fully functional. When the ALARMbutton is pressed, the system waits for a pre-programmed period of time, which is alittle longer than the maximum lift running time. If the lift is functional, it arrives inthe required station within this timeout and opens the door. In that case, the rescuerequest is cancelled. If the door fails to open, the request is accepted.Make sure before installation that the “door open” signal is available in the lift cabin.Requirements In double-door lifts, the signal has to be active only if both the doors opensuccessfully and let the people out. The door position signal has to work even in the case of power outage.Contact controlRequirements None of the CANCEL terminals may be connected electrically with any otherelectrical circuit and a voltage source other than the contact.Instructions1. Connect the CANCEL terminal into upper position.2. Make sure that the switch position matches the door contact configuration(open or closed when the door is closed) – see Address setting.Voltage controlRequirements DC 12 to 48V voltageInstructions1. Connect the CANCEL terminal into lower position.2. Make sure that the switch matches voltage presence or absence when the dooris closed – see Address Setting. Voltage presence corresponds to a closedcontact; voltage absence means an open contact.Warning Ignoring the instructions above may lead to product damage.Note Remember to program delayed calling to make the CANCEL connectionwork successfully.