22Installer ProgrammingRF Sensor Programming StepsQ-1 Select RF sensor # (01-48)Up to 48 wireless RF sensors can be used with each Control Panel. The optionsfor each sensor are programmed with sub-option questions.• Begin by entering the RF sensor number orselect it using the ← or → arrows.• After selecting the sensor number, program the sensor details byusing the ↑ and ↓ arrows to select each of the sub-options.✓ NOTE: To skip RF sensor programming, press SKIP to jump fromquestion Q-1 to question Q-2 (wired sensor programming).Select RF sensor (#) typeDEFAULT: Unused (00)Each RF sensor needs to be assigned to a sensor type. The sensor typedetermines how and when the Control Panel responds to signals from thesensor.Use this step to assign the sensor to a sensor type (zone).• Select the sensor type that matches the sensor’s function using the← or → arrows, or enter the sensor type number directly on the keypad.SENSOR TYPES(00) unused(01) exit/entry 1(02) exit/entry 2(03) perimeter(04) interior follower(05) day zone(06) 24-hour silent alarm(07) 24-hour audible alarm(08) 24-hour auxiliary alarm(09) 24-hour fire(10) interior with delay(14) 24-hour carbon monoxide(16) 24-hour fire with verifi cation(23) no response type(24) silent burglarySelect RF sensor (#) equipment typeDEFAULT: Varies by RF sensor type✓ NOTE: This question is only displayed when certain sensor types are selected.The equipment type selection will affect the sensor’s extended reporting code.The following sensor types require equipment type selection:SENSOR TYPE EQUIPMENT TYPES AVAILABLE(04) interior follower (1) = motion (2) = contact(06) 24-hour silent alarm (1) = contact (11) = emergency(07) 24-hour audible alarm (1) = contact (11) = emergency(08) 24-hour auxiliary alarm (1) = contact (6) = freeze (8) = water(10) = temperature (11) = emergency(10) interior with delay (1) = motion (2) = contact(23) no response type (1) = contact (2) = motion• Select the equipment type that matches the sensor equipment using the← or → arrows, or enter the equipment type number directly on the keypad.Select RF sensor (#) equipment codeDEFAULT: (0000) otherThe equipment code is a 4-digit code that is assigned to the model of sensorbeing used. The Control Panel will display a list of sensor models and theirassociated 4-digit equipment code.• Select the model of RF sensor being programmed for thissensor number using the ← or → arrows, or enter theequipment code number directly on the keypad.• Select “(0000) other” if the sensor model is not shown on the list. Theequipment code for the sensor can be entered using the next sub-question.SENSOR EQUIPMENT CODES(0000) other(0862) DW10-345 thin door/window contact(0863) DW20R-345 recessed door contact(0869) PIR1-345 PIR with pet immunity(0864) GB1-345 glass break detector(0895) SMKT2-345 GE smoke/heat detector (USA/Canada)(1058) SMKT3-345 2gig smoke detector(0872) SMKE1-345 smoke detector (USA)(0871) SMKE1-345C smoke detector (Canada)(0868) PANIC1-345 panic button remote(0860) CO1-345 CO detector (USA)(0859) CO1-345C CO detector (Canada)(1026) CO3-345 2gig CO detector (USA/Canada)(0873) TAKE-345 takeover module(0637) HW D/W “5816”(0470) HW R-D/W “5818MNL”(0533) HW PIR “5890”(0530) HW PIR “5894PI”(0519) HW Glass Break “5853”(0589) HW Smoke “5808W3”(0557) HW Heat Sensor “5809”(0624) HW Flood Sensor “5821”(0491) HW Panic Pendant “5802MN2”(0655) Existing door/window contact(0609) Existing motion detector(0475) Existing glass break detector(0616) Existing smoke detector(0692) Existing CO detector(0708) Existing heat sensor(0556) Existing flood/temp sensor(1061) GARAGE01 Resolution Products tilt sensor(1063) DBELL1-345 2gig doorbellEnter RF sensor (#) other equipment code (0-9999)DEFAULT: 0✓ NOTE: This question is only displayed if “(0000) other”is selected for a sensor’s equipment code.The equipment code is a 4-digit code that is assigned to the model of sensor beingused. If new equipment becomes available, the new equipment code should beentered here if the new equipment is not listed in the Sensor Equipment Codestable above.• Enter the equipment code number directly on the keypad for theRF sensor. (Enter “0” if the new equipment code is unknown.)