8.4.1 Using the OriginCplus - Recommended Method• Program the OriginCplus by inputting Prod ID, accurate date andtime of day. Press the # key to scroll through each field; after allfields are set as desired, press * to start the clock.• Make sure the camera has a battery attached.• Plug the Lemo5 cable of the OriginCplus into the Lemo5 chassismount on the base of the camera.• Press * on the OriginCplus to send the timecode information. TheOriginCplus will display Good OO.O after the timecode has beenaccepted in the camera. The control panel of the AATON 35-IIIwill display hours/minutes/seconds when the button marked Time ispressed. Toggling this button will also display year/month/day, thenthe production ID, then the equipment #.• Make sure to adjust the ASA selection to the exposure index of thefilm stock being used.• Disconnect the OriginCplus from the body and proceed to thenext device.8.4.2 Using an External SMPTE Device• Make sure the AATON 35-III has a battery attached and is notrunning.• Choose the SMPTE timecode device that will be supplying thetimecode (such as a Fostex PD2 or a Nagra IVS-TC). Set the timeof day and date, and set its clock to free run mode.• Connect a cable from the SMPTE output of the timecode deviceto the Lemo5 chassis mount on the base of the camera.• Set the on/off switch on the camera to run or test position, thenoff again; this will send the timecode information to the camerabody. The AATON 35-III will display hours/minutes/seconds whenthe button marked Time is pressed. Toggling this button will alsodisplay year/month/day and the equipment #. No production IDwill be recorded.• Disconnect the cable from the body and proceed to the next devi-ce.8.5 MONITORING AND MAINTAINING80