P. 46 - Chap. 7 Start-up and operationGBTime to serviceMakes it possible to check the first maintenance operation to be carried out on the compressor; themaintenance operations to be carried out 100 hours after this are also displayed. In this way, the usercan schedule maintenance operations and, if necessary, decide whether to replace several componentsduring the same maintenance operationComponents lifeindicates the remaining service life of each component that requires periodic maintenanceCompon. replacementIf the function is enabled, it makes it possible to reset the component life counters after maintenanceRunning hoursIndicates compressor operating time (total running hours, running hours at full load)A table with the schedule of the maintenance operations to be carried out is provided belowInterventionFirst 100 hoursmaintenancecouponFirst 1000 hoursmaintenancecouponEvery 1000 hours Every 2000 hoursCheck air filter •Replace air filter • •Change oil •Replace oil filter • • •Replace separatorfilter •Replace air dryerfilters • •Maintenance periods may differ from those indicated.During installation, Service Centre personnel assess compressor operating conditions and if necessary modifythe frequency of the operations.7.4.2.3GENERAL SETTINGS menuThis menu allows to carry out the general settings of compressor operating configuration with the exceptionof operating parameters (pressures, timings).LanguageUsed to select the language of the messagesMeasur. unitUsed to set the measurement units for pressure and temperature(continued on p . 49)