ABB-Welcome— 11 —P os: 43 /B usch-J aeg er (Neus truk tur )/M odul -S trukt ur/O nline-Doku mentatio n/Übe rsch rifte n ( --> Fü r alle Doku mente < -- )/1. E bene /A - F/B edienun g @ 11\ mod_ 127 918 554 164 9_15.doc x @ 8 304 3 @ 1 @ 18 OperationP os: 44 /B usch-J aeg er (Neus truk tur )/M odul -S trukt ur/O nline -Doku mentatio n/Bedi enung/Dim mer/B edie nun g - 6591 U-1 01 @ 23\ mod_13 330 912 931 58_ 15.d ocx @ 207 069 @ @ 1After programming, users can use a telephone to call the telephone gateway.When there is a call-in from outdoor station, and telephone is in normal standby:No. Function Command Example or explanation1 Accept call-in [1] [#]Commands below can be done via telephone when there is ongoing conversation between outdoor station andtelephone:No. Function Command Example or explanation1 Open default lock [3] [#] Open default lock of outdoor station2 Open the second lock [2] [#] Open the second lock of outdoor station3 Control switch actutor [5] [1] [#] to [5] [199] [#]When there is no ongoing conversation between outdoor station and telephone, user calls the telephone gateway,then1. When call divert to default phone number is activated, the telephone will play “calls are diverted” tone;2. When call divert to default phone number is deactivatedd, the telephone will play “calls are not diverted” tone.3. Settings below can be done via telephone:No. Function Command Example or explanation1 Call outdoor station [1] [1] [#] to [1] [9] [#] or [1] [#][1] [1] [#] to [1] [9] [#] to call a specialOutdoor station[1] [#] will call outdoor station 12Call outdoor station whenindoor station PIN isrequired[*] Indoor station number [*]Indoor station PIN [*] [1] [1] [#] to [1] [9] [#]or [*] Indoor station number [*]Indoor station PIN [*] [1] [#]3 Call the last call-in outdoorstation [1] [0] [#]4Call the last call-in outdoorstation when indoor stationPIN is must[*] Indoor station number [*]Indoor station PIN [*] [1] [0] [#]5 Open the default lock of thespecific outdoor station [3] [1] [#] to [3] [9] [#]6Open the default lock of thespecific outdoor station whenindoor station PIN is required[*] Indoor station number [*]Indoor station PIN [*] [3] [1] [#] to [3] [9] [#]7 Open the default lock of thelast call-in outdoor station [3] [0] [#]8Open the default lock of thelast call-in outdoor stationwhen indoor station PIN isrequired[*] Indoor station number [*]Indoor station PIN [*] [3] [0] [#]9 Open second lock of thespecific outdoor station [2] [1] [#] to [2] [9] [#]10Open the second lock of thespecific outdoor station whenindoor station PIN is required[*] Indoor station number [*]Indoor station PIN [*] [2] [1] [#] to [2] [9] [#]11 Open the second lock of thelast call-in outdoor station [2] [0] [#]12Open the second lock of thelast call-in outdoor stationwhen indoor station PIN isrequired[*] Indoor station number [*]Indoor station PIN [*] [2] [0] [#]13 Call guard unit [4] [#]14 Call guard unit when indoorstation PIN is required[*] Indoor station number [*]Indoor station PIN [*] [4] [#]15 Control switch actuator [5] [1] [#] to [5] [199] [#]