Operation Manual / 4 Product description / A150-M.. - A155-M..5 Operation and service Page 40 / 120© Copyright 2017 ABB. All rights reserved. HZTL4032_EN Revision F January 20175.4 Stopping the engineCAUTIONResidual heat in the turbochargerIf the residual heat in the turbocharger is not adequately dissipated, it maydamage the engine. Adequate cooling of the turbocharger must be ensured after stopping theengine. Run the engine for 5 ... 10 minutes at idling speed before stopping it. Observe the oil pressure specified for engine idling (see Table 5). For oil-cooled bearing casings, post-lubricate for 20 minutes if the turbine inlet temperature(t TE ) exceeds the following values when the engine is stopped:– 550 °C with insulated casing– 600 °C with non-insulated casingAt temperatures below the specified values, post-lubrication must be ensured until the ro-tors come to a standstill. ABB Turbo Systems recommends post-lubrication for 10 minutes. Observe the oil pressure specified for post-lubrication (see Table 5).