Operation Manual / 4 Product description / A100-M axial3 Commissioning / 3.2 Inspection procedures© Copyright 2017 ABB. All rights reserved. HZTL4033_DE Revision B December 20173.2 Inspection procedures3.2.1 IntroductionInspection procedures include preventative visual controls, monitoring and measuring workbefore and during commissioning. Inspection procedures enable changes to the turbochar-ger to be detected. Machine damage can be prevented.3.2.2 Checks before commissioningFilter mat (if available)u Check for damage and contamination.Lubricating systemCAUTIONContaminated oilSerious damage to engine or property can be caused by dirt and solid ma-terial particles in the oil.u For the initial commissioning phase and after all service work, flush thecomplete lubricating system with warm oil.u Use special running-in filters when running in the engine and after all ser-vice work on the lubricating system.u Check that the oil filter is clean before commissioning.u Check the oil pressure in the oil supply pipes.3.2.3 Checks after commissioning (engine in idle mode)Lubricating systemu Check the oil pressure in the oil supply pipes.u Check oil inlet temperature.The admissible values are specified in section Oil supply.Gas, air and oil pipesu After starting the engine, check all gas, air and oil pipes for leaks.Page 19 / 99