Program features 137Speed reference selection and scaling Speed reference selectionSpeed reference selection function sets the selection mode and priority of the speedreference inputs. The selection mode can be set with parameter 80.05 SPEED REFMODE.MULTIPLE – This mode can be used for multiple speed references. Up to eightseparate preset speed references can be programmed to the drive using parametersin group 80 SPEED REFERENCE and can be selected using binary coded digitalinputs.SEP HIGH PRI – This mode can be used when high speed reference has priority. Upto seven different speeds can be programmed to the drive and can be selected usingdedicated digital inputs. Each speed reference takes priority over the leveling speed.SEP LEVL PRI – This mode can be used when leveling speed reference has priority.Up to seven different speeds can be programmed to the drive and can be selectedusing dedicated digital inputs. The leveling speed reference, takes priority over allother speed references when enabled through one of the digital input terminals.The function calculates the final speed reference to be used by the elevator in thedifferent elevator operation modes, depending on the settings in parameters 80.05SPEED REF MODE, 80.06 SPEED REF SEL1, 80.07 SPEED REF SEL2, 80.08SPEED REF SEL3, and 80.09 SPEED REF SEL4.* The speed1 reference is fixed to a constant value 0 m/s. It can be used for stopping the elevator.Speed referencesavailableElevator operation modeSpeed 1*, 2, or 3 Normal travel modeNominal speed Normal travel modeMedium speed Normal travel modeLeveling speed Normal travel mode, when the leveling command is activeReleveling speed Reveling modeInspection speed Inspection mode or normal travel mode, depending on which mode is activeEvacuation speed Evacuation mode