2CDC172114M0201 25 www.abb.com/lowvoltage2019-09-06 V1.3AS-i dataThe enabling device with integrated AS-i technology contains up to three slaves, depending on theconfiguration.The following bit description relates to functions that are generally possible, and is set out in detail in thedata sheet enclosed with the product (or available from ABB), depending on the configuration.Custom versions HD5-B-901(up to 10 tuning devices may be used on one AS-i cable)Slave I/O type Bit Value DescriptionS-7.B.1.EAddress 01upondeliverySafe code1 D 0 emergency stop buttonSafe code1 D 1Safe code2 D 2Safe code2 D 3OutputNon safeD 0 0 feedback LED in emergency stop button, OFF1 feedback LED in emergency stop button, ONS-0.B.2.EAddress 02upondeliverySafe code1 D 0 enabling buttonSafe code1 D 1Safe code2 D 2Safe code2 D 3S-7.0.3.EAddress 03upondeliveryInputNon safeDI 0 0 additional button 1 (tab),not actuated1 additional button 1 (tab), actuatedDI 1 0 home position sensor, enabling devicenot hung up in holder1 home position sensor, enabling device hung up in holderDI 2 0 additional button 3 (lift),not actuated1 additional button 3 (lift), actuatedDI 3 0 additional button 4 (lower),not actuated1 additional button 4 (lower), actuatedOutputNon safeDO 0 0 green signal LED, OFF1 green signal LED, ONDO 1 0 red signal LED, OFF1 red signal LED, ONDO 2 0 assist light (flashlight), OFF1 assist light (flashlight), ONDO 3 0 vibration alarm, OFF1 vibration alarm, ON