Import to Compact HMI 800 Section 4 Engineering86 3BSE040587R44012. Open the Import Export tool and drag the “PLC Generic Control Network”object to the Import Export tool and drop it.3. In the Add Item dialog press Finish. All instances has now been exported withdependencies i.e the object types are included in the exported data.4. Save the file on a media to transport it to the Compact HMI 800.Import to Compact HMI 800Before the import can be done, the “PLC Controller Type” objects representing thecontrollers have to be manually created in the Compact HMI 800 system. This hasto be done because the configuration of these objects are dependent on theinstallation of the drivers in the node. So before proceeding, the steps for creating anew PLC Controller type should be followed for each controller. When allcontrollers have been created and configured, continue with the steps below:1. Copy the file to the Compact HMI 800 hard disc.2. Double click the file to start the Import Export tool.3. Select the Object Type structure in the structure selector box in the ImportExport tool.4. Right click the PLC Object Types Object and select import and then Finish.5. Select the Control structure in the structure selector box in the Import Exporttool.6. Expand to see the PLC Controller Type objects.7. For each PLC Controller Type object expand to see the children and use shiftclick selection to select all child objects.8. Right-click on the selected objects and select import.9. In the Importing dialog box select Import Settings and remove the selection“Include Dependencies”.10. Press Finish.11. When asked for the restore path (“Do You want to place manually“) select“Apply to all Items” and Yes.