Electromagnetic compatibility testsEMC immunity test level meets the requirements listed below1 MHz burst disturbance test, class IIICommon modeDifferential modeAccording to the IEC 60255-22-12.5 kV1.0 kVElectrostatic discharge test, class IVFor contact dischargeFor air dischargeAccording to the IEC 6100-4-2 andIEC 60255-22-26 kV8 kVRadio frequency interference testsConducted, common modeRadiated, amplitude-modulatedRadiated, pulse-modulatedAccording to the IEC 61000-4-6 andIEC 60255-22-610 V (rms), f = 150 kHz ... 80 MHzAccording to the IEC 61000-4-3 andIEC 60255-22-310 V/m (rms), f = 80 ... 2700 MHzAccording to the ENV 50204 andIEC 60255-22-310 V/m, f = 900 MHzFast transient disturbance testsAll terminalsAccording to the IEC 60255-22-4 andIEC 61000-4-44 kVSurge immunity testPower supplyAccording to the IEC 60255-22-5 and IEC 61000-4-54 kV, line-to-earth2 kV, line-to-linePower frequency (50 Hz) magnetic field According to the IEC 61000-4-8300 A/m continuousElectromagnetic emission testsConducted, RF-emission (Mains term.)Radiated RF-emissionAccording to the EN 55011EN 55011, class A, IEC 60255-25EN 55011, class A, IEC 60255-25CE compliance Complies with the EMC directive 2004/108/EC and the LVdirective 2006/95/ECStandard testsMechanical testsVibration tests (sinusoidal)Shock and bumb testAccording to the IEC 60255-21-1, class IAccording to the IEC 60255-21-2, class ISupply current consumptionRunning 340 mAStart up 430 mAEthernet Adapter SPA-ZC 4001MRS755450Technical data (cont´d)6RoHS ComplianceComplies with the RoHS directive 2002/95/EC