ABB Stanilite T8 Nexus RF Installation Manual
—ABB Australia Pty LimitedFor enquiriesABB contact centre: 1800 60 20 20E-mail: AU-ABB-Stanilite@abb.comwww.stanilite.com.au © Copyright 2020 ABB. All rights reserved.Troubleshooting guideIf you have installed and connected the fitting as per the instructions listed earlier and it doesnot function correctly, use the following table as a guide to fixing the problem. Look up thetype of fault in the left column and check the possible causes from the right column.If the fitting still does not work after checking these possible causes, contact ABB customerservice in Australia on 1800 60 20 20.No. Fault Possible causes1 LED not lit; orLED not flashing greenAC supply not connected; orAC supply turned off2 LED is flashing green but AC lamp does not come onwhen connected to mainsSwitch active supply turned off; orMissing loop from unswitched to switched active; orLamp damaged; orLamp not inserted properly3 LED is flashing green but lamp does not come on whentest switch is pressedLamp damaged or lamp not inserted properly; orBattery pack not connected; orBattery pack damaged; orTest switch damaged4 LED not red after the commissioning Battery pack not connected; orLED wire not properly inserted into the terminalblock5 Lamp is lit momentarily when test switch is pressed; orWhen mains failBattery not fully charged (allow up to 24 hours); orBattery pack damaged6 LED is constant green Fitting self checks fail - return to manufacturer7 Fitting LED is not flashing yellow/orange under winknode commandFitting is not receiving communication signal. Checkdata cable wiring path and cable connections. Referto Nexus RF user guide.Construction sitesContinuously switching off the mains powersupply that is connected to emergency lightfittings during the construction phase of aninstallation will cause these fittings to dischargeand charge their batteries many times over ashort period; this can shorten life of the battery.ABB does not recommend such practices andmay not honour the warranty on batteries whenthey are subjected to such harsh operatingconditions. Emergency light fittings are designedto be discharge tested once every 6 months asper AS/NZS 2293.2, subjecting the product torepeated discharge or charge cycles is regardedas an abuse of the fittings.Testing precautionsOnce the fitting is permanently connected to themains supply, a commissioning discharge test asrequired in AS/NZS 2293.2 must be carried out.You will need to allow 24 hours for the battery tofully charge prior to conducting this test,presently (at the time of writing), the standardrequires that fittings operate in emergency modefor a period not less than 2 hours for theircommissioning test and for not less than 90minutes thereafter (it is required that 6 monthlydischarge tests be carried out). You will need tokeep the records for the commissioning test andenter them into the building emergency serviceslogbook or via other recording methods asallowed by AS/NZS 2293.2.—I N S TA L L AT I O N M A N U A LStanilite®Power pack T8Nexus® RFThank you for choosing ABB productPlease read this document thoroughly beforecommencing installation and retain for futurereference. Contact ABB customer service inAustralia on 1800 60 20 20 if you need anyassistance. The installation instructions werecorrect at the time of print. To reflect changes intechnology and Australian standards; ABBreserves the right to amend the instructionswithout notice. Updated document can be foundon the Stanilite website.Safety warningIn Australia and New Zealand, only licensedelectricians are permitted by law to work with240 volt electrical installations.Do not attempt to install or connect this productunless you are a licensed electrician.Turn off and isolate the electrical supply beforeconnecting this fitting to the building wires.Do not touch the terminals of the terminal blockwhen the light fitting is energised.The only user-serviceable part is the battery.Do not attempt to service other parts of thefitting as this will void the warranty.As the installer, it is your responsibility to ensurecompliance with all relevant building and safetycodes, (ie: AS/NZS 3000, AS/NZS 2293). Refer tothe applicable standards for data and mainscabling installation procedures andrequirements.This document covers What’s inside the boxSafety warning Power pack T8 Nexus RFInstallation instructions Installation manualRemoval instructions Warranty informationTesting precautionsTroubleshooting guideImportant to note:• This product is designed for indoor use only.EMC warningPower pack complies with EMC regulations. Weadvise that if you incorporate this pack intoyour product (batten/fitting) you must test thecomplete (product/fitting) for EMC compliance.PL Lamp warningFor PL lamp application it is recommended thatthe power pack be used without a LDR. The fittingshould be designated as a non-maintained fitting.The LDR is not designed to be affixed to a PL lamp.If AC lamp monitoring is required then the LDRmust be mounted adjacent to the PL lamp. Pleasecontact ABB customer service on 1800 60 20 20if you require more information. Specific PL lamppower packs are supplied without a LDR and areprogrammed as non-maintained.Nexus RF (wireless system)The Nexus RF power pack is a wireless RF systemmonitor conversion kit suitable for AC fluorescentluminaire to be converted to Nexus RF fluorescentemergency luminaire, they communicate via aproprietary RF network system. The power packcomes complete with Nexus RF MAC addresslabel. Affix the Nexus RF MAC address labelsupplied with the power pack on to the retrofittedemergency fitting in a recognisable position forrecording upon installationDoc no. 29-01092_19AKK107680A8424 - A - June 2020 |
Related manuals for ABB Stanilite T8 Nexus RF
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine