ACECO FC3002 Quick Start Manual
IntroductionThe Aceco FC3002 is the latest advance in hand-held radio frequency finder / counter. It excels at finding frequencies forsecure monitoring applications. It automatically and instantly tunes ICOM CI-V or AOR receivers to the frequency it finds. Itis compact, truly pocket-sized and is designed for ease of use and reliable performance. It comes complete with internalNiCd pack, AC wall charger, 7 section telescopic antenna and interface cable.SpecificationsFrequency range: 1 MHz - 3 GHzWeight: 250 gSize: 100 mm high x 68 mm wide x 31 mm deepImpedance: 50 Ohms (BNC Socket)Case: Stamped aluminum with black anodized finishBattery: Internal 4 x AA 600 mAH NiCd packPower: 9 VDC 300 mATimebase: Less than 1 PPM at room temperatureFeaturesl 10 digit Liquid Crystal Displayl Low power consumption (Average 6 hour battery life)l LED back lightl Supplied with NiCd pack, AC wall charger, telescopic antenna and interface cablel Measures frequency and periodl Automatically holds and tunes ICOM CI-V or AOR receiversl Filter prevents display of random noisel Hold switch to lock displayl Low battery indicatorl Beeperl 4 selectable gate speedsl Ultra sensitive synchronous detector 16 section bargraph to show RF signal strengthl High speed 300 MHz direct counter with 0.1 Hz resolutionControls1. Power Switch. This slide switch turns the RF finder on which also initiates a 2 second test of all the LCD segments.2. Com Switch. This slide switch selects either the ICOM CI-V receivers or the AOR receivers.3. Range Switch. This should be switched to the 300 MHz position for frequencies between 1 MHz and 300 MHz andswitched to the 3 GHz position for frequencies between 10 MHz and 3 GHz.4. Lite Switch. This slide switch turns the LCD back light on and off.5. Filter Switch. Slide the switch to turn the filter on and off.6. Function Button. This selects the frequency or period. This button has four settings. One each for displayingfrequency or period as these are received, and two settings for automatic hold and tune of the first frequency or periodfound.7. Hold Button. This holds the current display and stops the RF finder from counting.8. Gate Button. This selects the gate or measurement time. A longer gate time allows counting for longer period andresults in higher accuracy.9. Calibration. The calibration adjustment opening is located on the front panel of the RF finder. This allows access tothe trimmer capacitor that provides about a 10 PPM adjustment range of the time base oscillator. This is not usuallynecessary but to do so read a signal of a known frequency before adjusting the trimmer for correct frequency display.If you calibrate at 4.1943 MHz or above then the RF finder will be more accurate.ACECO FC3002RF FINDER |
Related manuals for ACECO FC3002
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine