- - 82Note: S-curve characteristics time refers to the time from acceleration rate 0 to thetime when a normal acceleration rate determined by a specified acceleration timeis obtained.The figure below shows the time chart at FWD/REV run change during deceleration and stop.2.7.10 FREQUENCY COMMAND GAIN/BIASItem Name Constant to be set Factory PresetFrequency Reference Gain 22 1.00Frequency Reference Bias 23 0.00Output frequency (gain/bias) can be set freely according to frequency setting ( 0 to 10 vOr 4 to 20 mA).S-CURVE CHARACTERISTICS TIME (TSC)FWD RUNREV RUNACCELER- DECELER-DC INJECTIONBRAKINC TIMEACCELERATIONOUTPUTMIN. OUTPUTFREQUENCY: S-CURVE CHARACTERISTICDC INJECTION BRAKINCSTART FREQUENCYMIN. OUTPUTFREQUENCYDECELER-Pn-02 * Pn-22100%BIASPn-02 * Pn-2310 v(20mA)Fref[Hz]SET FREQUENCY REF.0(4mA )