Y1-03-0233 Rev. D 39APPENDIX H - TECHNICAL SPECIFICATIONSGENERAL/ ENVIRONMENTALBeacon size (without antenna) 17.7 H X 10.67 W X 9.09 D cm (6.97 X 4.2 X 3.58 in)Display size 2.54 cm (1.0 in) diagonalBeacon weight 581 g (20.49 oz)Beacon material High impact UV resistant polymerColor ACR-Treuse™ (high visibility yellow)Waterproof Tested to 10 min @10 m (33 ft), exceeds RTCM standardBuoyant YesDeployment Category I: Automatic hydrostatic releaseCategory II: ManualBATTERYOperational life 48 hours minimum @-20ºC (-4ºF) (Class 2)Battery type andreplacement intervalLiMnO25 years from date beacon placed in service,or after use in an emergency not to exceed batteryexpiryOperating temperaturesStorage temperatures-20º C to +55º C (-4º F to +131º F) (Class 2)-30º C to +70º C (-22º F to +158º F) (Class 2)406 MHz TRANSMITTERFrequency 406.037 MHzPower output 5 WDigital message format Standard location protocol (for the USA; Beacon can bereprogrammed at a service center to other codedformats, and to national location protocol)121.5 MHz TRANSMITTERFrequency 121.5 MHzPower output 25 mW PEPModulation type AM (3K20A3X)LED STROBELight color WhiteOutput power 1 cd (effective candela)Flash rate 20-30/ minRange 360º visibilityGENERALAccessories SeaShelter3™ Category I Mounting bracket, ACRP/N 9501LowPro3™ Category II Mounting bracket, ACR P/N9502HydroFix™ universal hydrostatic release (HRU) kit,ACR P/N 9490Approvals FCC ID #B66ACR-RLB36COSPAS-SARSAT certificate #189USCG #161.011/86/0MED EC Type Examination (Module B) CertificateNo.: BSH/4612/5060959/08NOTE: For complete information regarding beacon type approvals, please visit ACR’swebsite at www.acrelectronics.com