6 5G. AIR JET ASSEMBLY1. Air Jet Assembly DescriptionThe air jet assembly is located in the left front base of the dryer. The air jet is designed to operate at the endof each cycle for thirty (30) seconds, to remove lint which may have accumulated on the blower (impellor)fan blades. This function will be interrupted if the main door or lint drawer is opened before the air jet cycleis complete.2. Air Jet Component Replacementa. 24 VAC 3-Way Pressure Valve Replacement1) Disconnect compressed air supply from the dryer.2) Discontinue electrical service to the dryer.3) Remove the 1/4" x 1/8" M.P.T. connection from the 3-way pressure valve body.4) Remove the two (2) #10-16 x 1/2" crimptite TEK screws.